Yodify Product Library
Instantly add the AX410 Single Channel Transmitter for 2-Electrode Conductivity Sensor and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
AX410 Single Channel Transmitter for 2-Electrode Conductivity Sensor
Brand: ABB GroupThe AX400 transmitter is a dual input, 4-wire transmitter.
The AX400 analyzers incorporate the latest technology to provide highly reliable, flexible, feature-packed devices that satisfy a diverse range of process monitoring and control applications.
The complete range encompasses solutions for pH/Redox (ORP), conductivity and dissolved oxygen.
Features- Cost effective
- select one or two conductivity inputs or combine conductivity and pH/Redox (ORP) in one analyzer
- integral PID controller
- Reduced installation cost
- easy access terminations; reduced panel space
- High functionality at minimum cost
- conductivity, resistivity, difference, ratio, % passage, % rejection and inferred pH calculations
- Expanded monitoring and control
- add-on option board provides a total of five alarm relays and four current outputs
- service logbook providing historical data
- Energy saving
- high visibility, backlit display with auto switch-off function
- Reduced yearly maintenance costs
- 30 Vdc option negates the need for costly safety tests
1 - 12 of 90 Part Numbers
AX41010001
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010002
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010003
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010101
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010102
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010103
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
- Power Supply - 12 to 30 Vdc
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011001
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011002
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011003
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 100 to 240 Vac 50/60 Hz
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011101
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - English
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011102
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - French
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011103
- First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
- Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
- Enclosure Type - Wall-Mount IP65, General
- Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
- Power Supply - 12 to 30 Vdc
- Manual - Italian
- Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
1 - 12 of 90 Part Numbers
Specifications
Brand
Mounting
- Wall Mounting
- Panel Mounting
- Pipe Mounting
Environmental Protection
- NEMA 4X
- IP65
- IP66
Power Supply
- 12-30 Vdc
- 85-265 Vac
Power Consumption
- 10 W
Range
- Programmable 0 to 0.5 to 0 to 10,000 µS cm-1
Span
- (10 to 10,000) x Cell Constant
Accuracy
- > ± 0.01 % of Span (0 to 100 µS cm-1)
- > ± 1 % of Reading (10,000 µS cm-1)
Temperature Sensor
- Pt100
- Pt1000
Operating Temperature
- Conductivity: -10° to 200° C (14° to 392° F)
- -20° to 55° C (-4° to 131° F)
Storage Temperature
- -25° to 75° C (13° to 167° F)
Temperature Compensation
- Conductivity: -10° to 200° C (14° to 392° F)
Communication
- PROFIBUS DP
Humidity
- Up to 95 % Relative Humidity Non-Condensing
Certifications & Approvals
- EMC
- CE
- UL
Controller Type
- P, PI, PID (Configurable)
Control Output
- Proportional Band: 0.1 to 999.9 %, Programmable in increments of 0.1 %
- Pulse frequency: 1 to 120 pulses per minute
- Time proportioning cycle Time: 1.0 to 300.0 s, Programmable in increments of 0.1 s
- Current output Control: 0 to 100 %
- Derivative: 0.1 to 999.9 s in increments of 0.1 s
- Integral Action Time (Integral Reset): 1 to 7,200 s, Programmable in increments of 1 s (0 = Off)
- Water & Wastewater Treatment
- Power, Pure Water
- Semiconductors
- Chemicals
- Pharmaceuticals
- Pulp & Paper
Documentation
Brochure
Certificate
Manual
- Instruction - AX4xx and AV4xx series transmitters | Display driver selection | LCD display module (AX400/0295) pdf 1.7 MB
- Manual - AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 | Single and dual input analyzers for low level conductivity Summary: User Guide pdf 1.3 MB
- Manual - User guide supplement - AX400 series | Single and dual input analyzers | PROFIBUS® datalink description pdf 602 KB