Yodify Product Library
Instantly add the AX410 Single Channel Transmitter for 2-Electrode Conductivity Sensor and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

AX410 Single Channel Transmitter for 2-Electrode Conductivity Sensor

Brand: ABB Group

The AX400 transmitter is a dual input, 4-wire transmitter. 

The AX400 analyzers incorporate the latest technology to provide highly reliable, flexible, feature-packed devices that satisfy a diverse range of process monitoring and control applications. 

The complete range encompasses solutions for pH/Redox (ORP), conductivity and dissolved oxygen.
Features
  • Cost effective
    • select one or two conductivity inputs or combine conductivity and pH/Redox (ORP) in one analyzer
    • integral PID controller 
  • Reduced installation cost
    • easy access terminations; reduced panel space
  • High functionality at minimum cost
    • conductivity, resistivity, difference, ratio, % passage, % rejection and inferred pH calculations
  • Expanded monitoring and control
    • add-on option board provides a total of five alarm relays and four current outputs
    • service logbook providing historical data
  • Energy saving
    • high visibility, backlit display with auto switch-off function
  • Reduced yearly maintenance costs
    • 30 Vdc option negates the need for costly safety tests

1 - 12 of 90 Part Numbers
AX41010001
AX41010001
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010002
AX41010002
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010003
AX41010003
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010101
AX41010101
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010102
AX41010102
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41010103
AX41010103
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011001
AX41011001
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011002
AX41011002
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011003
AX41011003
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011101
AX41011101
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011102
AX41011102
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX41011103
AX41011103
  • First Process Variable (PV1) - Conductivity 0 to 10,000 µS cm-1 for 2-Electrode Sensors
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
1 - 12 of 90 Part Numbers

Specifications

Brand

Mounting

  • Wall Mounting
  • Panel Mounting
  • Pipe Mounting

Environmental Protection

  • NEMA 4X
  • IP65
  • IP66

Power Supply

  • 12-30 Vdc
  • 85-265 Vac

Power Consumption

  • 10 W

Range

  • Programmable 0 to 0.5 to 0 to 10,000 µS cm-1

Span

  • (10 to 10,000) x Cell Constant

Accuracy

  • > ± 0.01 % of Span (0 to 100 µS cm-1)
  • > ± 1 % of Reading (10,000 µS cm-1)

Temperature Sensor

  • Pt100
  • Pt1000

Operating Temperature

  • Conductivity: -10° to 200° C (14° to 392° F)
  • -20° to 55° C (-4° to 131° F)

Storage Temperature

  • -25° to 75° C (13° to 167° F)

Temperature Compensation

  • Conductivity: -10° to 200° C (14° to 392° F)

Communication

  • PROFIBUS DP

Humidity

  • Up to 95 % Relative Humidity Non-Condensing

Certifications & Approvals

  • EMC
  • CE
  • UL

Controller Type

  • P, PI, PID (Configurable)

Control Output

  • Proportional Band: 0.1 to 999.9 %, Programmable in increments of 0.1 %
  • Pulse frequency: 1 to 120 pulses per minute
  • Time proportioning cycle Time: 1.0 to 300.0 s, Programmable in increments of 0.1 s
  • Current output Control: 0 to 100 %
  • Derivative: 0.1 to 999.9 s in increments of 0.1 s
  • Integral Action Time (Integral Reset): 1 to 7,200 s, Programmable in increments of 1 s (0 = Off)

  • Water & Wastewater Treatment
  • Power, Pure Water
  • Semiconductors
  • Chemicals
  • Pharmaceuticals
  • Pulp & Paper
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more