Yodify Product Library
Instantly add the Series GFC Gas Mass Flow Controller and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Series GFC Gas Mass Flow Controller

Brand: Dwyer Instruments, LLC

The Series GFC Gas Mass Flow Controllers combines a straight tube sensor with a restrictor flow element.

It is available for flow ranges up to 1,000 L/min and offered in aluminum or 316 SS in 1/4", 3/8", 1/2" and 3/4" sizes.
Features
  • Provides High Accuracy and Repeatability
  • Flow rates are virtually unaffected by temperature and pressure variations
  • Utilizes an electromagnetic valve and PID electronics to maintain continuous control by comparing measured sensor signal set to flow rates
  • Set points can be adjusted with local potentiometers or remotely via 0 to 5 Vdc or 4 to 20 mA Analog signal
  • Actual gas flow is displayed in engineering units on a 3-1/2 digit, 90° tiltable LCD readout
  • Can be used with Series GFT2 Flow Totalizer for applications requiring totalization
  • NIST Traceable Certificate Included

1 - 12 of 32 Part Numbers
GFC-1101
GFC-1101
DWYER Gas Mass Flow Controller, Range 0-10 mL/m. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 10 mL/m, 1/4"
GFC-1102
GFC-1102
DWYER Gas Mass Flow Controller, Range 0-20 mL/m. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 20 mL/m, 1/4"
GFC-1103
GFC-1103
DWYER Gas Mass Flow Controller, Range 0-50 mL/m. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 50 mL/m, 1/4"
GFC-1104
GFC-1104
DWYER Gas Mass Flow Controller, Range 0-100 mL/m (SCCM). Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 100 mL/m, 1/4"
GFC-1105
GFC-1105
DWYER Gas Mass Flow Controller, Range 0-200 mL/m. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 200 mL/m, 1/4"
GFC-1106
GFC-1106
DWYER Gas Mass Flow Controller, Range 0-500 mL/m. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 500 mL/m, 1/4"
GFC-1107
GFC-1107
DWYER Gas Mass Flow Controller, Range 0-1000 mL/m. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 1,000 mL/m, 1/4"
GFC-1108
GFC-1108
DWYER Gas Mass Flow Controller, Range 0-2 LPM. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 2 L/min, 1/4"
GFC-1109
GFC-1109
DWYER Gas Mass Flow Controller, Range 0-5 LPM. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 5 L/min, 1/4"
GFC-1111
GFC-1111
DWYER Gas Mass Flow Controller, Range 0-15 LPM. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 15 L/min, 1/4"
GFC-1131
GFC-1131
DWYER Gas Mass Flow Controller, Range 0-30 LPM. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 30 L/min, 1/4"
GFC-1133
GFC-1133
DWYER Gas Mass Flow Controller, Range 0-50 LPM. Specified Flow Range Is for An Equivalent Flow of Nitrogen at 70°F (21°C) @ 760 mm Hg, 1/4" Compression Fitting.
  • Model - Aluminum
  • Flow Range - 0 to 50 L/min, 1/4"
1 - 12 of 32 Part Numbers

Specifications

Accuracy

  • ± 1 % of Full Scale
  • ± 1.5 % of Full Scale

Approvals & Certifications

  • CE

Display

  • 3´ Extension Cable for LCD Readout
  • 3-1/2-Digits

Filter

  • 5 microns

Flow Rate

  • 0 to 1,000 L/minute
  • 0 to 1,000 mL/m

Media

  • Clean Gases Compatible with Wetted Parts

O-Ring Material

  • 316 Stainless Steel
  • Fluoroelastomer

Output

  • 0-5 Vdc
  • 4-20 mA

Power Requirement

  • ± 12 Vdc

Pressure Range

  • psig: 500 to 1,000 (kPa: 3,447 to 6,895, bar: 34.5 to 68.9)

Repeatability

  • ± 0.25 % of Full Scale

Response Time

  • 2 seconds to within ± 2 % of Actual Flow

Supply Voltage

  • 110 V
  • 110 Vac
  • 220 V
  • 220 Vac

Temperature Range

  • 0° to 50° C (32° to 122° F)

Tube Connection

  • 1/2” Compression Fitting
  • 1/4” Compression Fitting
  • 3/8” Compression Fitting

Wetted Materials

  • Aluminum - Anodized
  • Brass

  • Gas Flow Measurement
  • Gas Flow Control
  • Operating Pumps and Valves
  • Process Equipment
  • Vacuum Processes
  • Glass and Metal Coating
  • Film Depostition
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more