Yodify Product Library
Instantly add the LTF Series Long-Range Time-of-Flight Laser Sensor and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
LTF Series Long-Range Time-of-Flight Laser Sensor
Brand: Banner EngineeringHigh-performance LTF Series Sensors detect targets regardless of color, material or sheen from up to 24 meters away, straight-on or at an angle.
Features- Analog and discrete or dual discrete outputs for measuring and detection applications.
- Best in class combination of range, repeatability and accuracy enable highly reliable target detection and precise distance measurement.
- Two-line, eight-character display and pushbutton programming for easy setup, troubleshooting and real-time distance measuring.
- Durable IP67 housing, high ambient light immunity and stable performance across temperatures provide reliable performance in challenging environments.
- Advanced options, including delay timers, advanced triggered measurement modes and cross-talk avoidance.
- Available in models with IO-Link communication which enables remote configuration and monitoring and simplifies wiring, preventative maintenance, and device replacement.
1 - 12 of 20 Part Numbers
LTF12IC2LD
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 1mm
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 2 m
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12IC2LD W/30
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 1mm
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 9 m
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12IC2LDQ
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 1mm
- Connection - Integral QD
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12IC2LDQP
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 1mm
- Connection - Pigtail QD
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12KC2LDQ
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Linearity (mm) - +/- 10
- Analog Resolution/Discrete Repeatability - 1mm
- Connection - Integral QD
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted or manually settable from 2 to 11950 mm
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Pump-in/ Pump-out - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Discrete
- IO Link - Yes
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12KC2LDQP
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Linearity (mm) - +/- 10
- Analog Resolution/Discrete Repeatability - 1mm
- Connection - Pigtail QD
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 2 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted or manually settable from 2 to 11950 mm
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Pump-in/ Pump-out - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Discrete
- IO Link - Yes
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12UC2LD
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 0-10 V dc
- Analog Resolution/Discrete Repeatability - 1mm
- Analog Voltage Output Rating - 2.5 kΩ min. load impedance
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 2 m
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12UC2LD W/30
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 0-10 V dc
- Analog Resolution/Discrete Repeatability - 1mm
- Analog Voltage Output Rating - 2.5 kΩ min. load impedance
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 9 m
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12UC2LDQ
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 0-10 V dc
- Analog Resolution/Discrete Repeatability - 1mm
- Analog Voltage Output Rating - 2.5 kΩ min. load impedance
- Connection - Integral QD
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF12UC2LDQP
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 0-10 V dc
- Analog Resolution/Discrete Repeatability - 1mm
- Analog Voltage Output Rating - 2.5 kΩ min. load impedance
- Connection - Pigtail QD
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 12000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - M12 (Euro) requires mating cordset
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF24IC2LD
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 1mm
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted or manually settable from 2 to 23950 mm
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Pump-in/ Pump-out - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 24000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 2 m
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm, 35 mm at 24000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
LTF24IC2LD W/30
- Adjustments - Push Button; Remote Teach
- Alarm Output (mA) - 100
- Analog Current Output Rating - 1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
- Analog Linearity (mm) - +/- 10
- Analog Output Configuration - 4-20 mA
- Analog Resolution/Discrete Repeatability - 1mm
- Connection - Cable
- Delay at Power-up (ms) - 2000
- Discrete (Switched) Outputs - 1 NPN/PNP Configurable
- Discrete Output Hysteresis (mm) - Automatically adjusted or manually settable from 2 to 23950 mm
- Feature: Chemical Resistant - No
- Feature: Health/ Marginal Signal Output - Yes
- Feature: Pump-in/ Pump-out - Yes
- Feature: Remote Teach - Yes
- Feature: Timing (Hold/Delay) - Yes
- Housing Style - Rectangular
- Indicator - Display; LED(s)
- Input/output - Analog & Discrete
- IO Link - No
- IP Rating - IP67
- Laser Classification - Class 2
- Laser Control - Yes
- Max Ambient Light (Lux) - 40000
- Max Discrete (Switched) Output (mA) - 100
- Max Off-state Leakage Current (µA) - PNP <10µA at 30V, NPN <200µa at 30V
- Max Op. Relative Humidity Non-Condensing (%) - 90 at 55°C
- Max Operating Temperature (°C) - 55
- Max Sensing Distance (mm) - 24000
- Mechanical Shock - IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
- Min Operating Temperature (°C) - -20
- Minimum Response Time (ms) - 1.5
- Minimum Sensing Distance (mm) - 50
- Minimum Window Size (mm) - 10
- NEMA Rating - NEMA 6
- Number of Pins - 5
- Output Protection - Protected against continuous overload and short circuit
- Output Saturation Voltage NPN Outputs - < 1.6V @ 100ma
- Output Saturation Voltage PNP Outputs - < 3V @ 100ma
- Power Supply - 12-30 V dc
- Power/Current Consumption (exclusive of load) - <85 mA @ 24 V (< 2.1 W)
- Primary Housing Material - Zinc Alloy Die-Cast
- QD Type/Cable Length - 9 m
- Sensing Beam - Visible Red Laser
- Sensing Beam Wavelength (nm) - 660
- Sensing Mode (Detailed) - Time of Flight
- Sensing Mode (General) - Proximity
- Spot Size (@ Reference Distance) - 6.5 mm at 50 mm, 12.5 mm at 12000 mm, 35 mm at 24000 mm
- Storage Temperature (°C) - -30 to 65
- Supply Protection Circuitry - Protected against reverse polarity and transient overvoltages
- Temperature Effect (mm/°C) - 0.25mm/C (typical)
- Typical Laser Lifetime (Hours) - 60000
- Vibration - MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Warm-up Time (minutes) - 15
- Window Material - Acrylic
- Wireless - No
1 - 12 of 20 Part Numbers
Documentation
Data Sheets
- Banner Engineering LTF Series Long-Range Time-of-Flight Laser Sensor Data Sheets pdf 998 KB
- IO Link Data Reference Guide LTF Series pdf 123 KB
- LTF Sell Sheet pdf 1.4 MB
- LTF Sell Sheet Brazil pdf 1.4 MB
- LTF Sell Sheet Japan pdf 1.4 MB
- LTF Sell Sheet Korean pdf 1.5 MB
- LTF Sell Sheet Mexico pdf 1.3 MB
- LTF Sell Sheet Taiwan pdf 998 KB
Product Manuals
- Banner Engineering LTF Series Long-Range Time-of-Flight Laser Sensor Product Manuals pdf 2.9 MB
- L GAGE LTF Laser Distance Sensor with IO Link Instruction Manual pdf 2.9 MB
- L GAGE LTF Time of Flight Laser Distance Sensor Instruction Manual pdf 2.9 MB
- L GAGE LTF Time of Flight Laser Distance Sensor Instruction Manual Japanese pdf 3.8 MB