Fluxus G704 CA Compressed Air Flow Meter
Brand: FLEXIMCompressed Air Flow Meter.
Non-invasive compressed air flow measurement - FLUXUS G704 CA.
Compressed air is a very expensive form of energy. This is due to its efficiency: for every joule of mechanical work which is done with a pneumatic tool, approximately twenty times the amount of electrical energy must be spent.
However, despite this poor yield, compressed air is practically indispensable in many industries because of its production-related advantages.
This makes it all the more important to use the valuable medium as efficiently as possible.
Measurement creates Transparency.
If you want to avoid waste it's necessary to measure.
Through the precise detection of the current volume flow, components of a system can be dimensioned in a particularly cost-effective manner through the fast and unmistaken identification of possible overloads (such as when air velocities are too high) or malfunctions in the network.
The exact assignment of consumption proportions to individual production stages also offers possibilities for fact-based, economic decisions.
Moreover, the volume-flow measurement indicates the amount of compressed air lost as a result of leaks – an important economic factor, as every third compressor is operated only to compensate for air losses.
But how do you best measure compressed air flows? Non-invasively, of course!
The FLUXUS G704 CA compressed air flow meter is thus the ideal solution.
FLEXIM’s non-invasive clamp-on ultrasonic technology is unique in that it can be applied to measure compressed air flow rates even at very low pressures (down to 3bar on steel lines and atmospheric pressure on plastic lines).
Also even the lowest flow rates are accurately captures revealing the slightest flow rates from the smallest leaks where there should be none.
For this reason, the FLUXUS G704 CA is particularly suitable for non-invasively measuring quantities drawn off at individual points in the compressed air grid as well as detecting leaks within it.
Due to being non-invasive by principle, the FLUXUS G704 CA can never be a potential source of leaks by itself.
Specifications
Brand
Additional Notes
- Minimum Operational Pressure: 45 psi on Steel Pipes, Atmospheric Pressure & Below on Plastic Pipes
Communication Protocol
- Modbus RTU, M-Bus, BACnet MS/TP, RS-485
Degree of Protection Transmitter
- NEMA 4
Explosion Protection
- FM Class I, Div. 2 or ATEX, IECEx Zone 2
Flow Channels
- 1 or 2
Flow Velocity Range
- 0.03 to 115 ft/sec (Dependent on Pipe Size)
Inputs
- 2, Available Are: Temperature (Pt 100, Pt 1000), Current
Measurement Accuracy
- ± 1 % to 3 % of Reading, ± 0.03 ft/sec, Depending on Application ± 0.5 % of Reading, ± 0.03 ft/sec, Field Calibrated
Media Temperature
- -40° to +338° F
Operating Temperature of the Transmitter
- -40° to 140° F
Outputs
- 4, Available Are: Switchable Current, Binary
Pipe Diameter Range
- 0.28” to 9.8”
Repeatability
- ± 0.15 % of Reading, ± 0.03 ft/sec
Documentation
Brochure
Specifications
- FLUXUS G704CA Technical Specification DE pdf 185 KB
- FLUXUS G704CA Technical Specification EN pdf 184 KB
- FLUXUS G704CA Technical Specification FR pdf 186 KB
- FLUXUS G704CA Technical Specification US pdf 181 KB
- FLUXUS G70x Technical Specification DE pdf 1.8 MB
- FLUXUS G70x Technical Specification EN pdf 1.8 MB
- FLUXUS G70x Technical Specification ES pdf 1.8 MB
- FLUXUS G70x Technical Specification FR pdf 1.8 MB
- FLUXUS G70x Technical Specification NL pdf 1.8 MB
- FLUXUS G70x Technical Specification US pdf 1.1 MB