Hyperchill Plus - Industrial Water Chiller for Precision Cooling of Low Viscosity Industrial Cooling Fluids
Brand: Hiross - by ParkerExtremely compact and easy to use, Hyperchill Plus is designed for safe and reliable operation in the most varied working conditions, providing precise and accurate control of low viscosity process fluid temperature.
The availability of a wide range of accessories and options makes Hyperchill Plus a very flexible solution that fits the needs of a wide variety of industrial applications.
With a non-ferrous hydraulic circuit, Hyperchill Plus is suitable for cooling low viscosity cooling fluids including water and water-glycol mixtures.
Hyperchill Plus ensures stable working conditions combined with improved efficiency and productivity of the process.
Hyperchill Plus contributes significantly to the reduction of plant downtime and maintenance costs due to inconsistent cooling of low viscosity cooling fluids.
Each individual Hyperchill Plus unit is extensively tested to guarantee efficient operation and reliability in most working conditions.
Features- Complete solution, easy to install and manage
- Non-ferrous hydraulic circuit including non-ferrous water tank
- A differential pressure switch ensures system shut down if the circuit runs dry
- Completely configurable with many options and kits to fit the needs of a wide variety of industrial applications
- Maximum ambient temperature up to 48 °C on standard units, topicalization up to 53 °C
- Use of compliant scroll compressors (on ICEP007 and larger)
- Low ambient speed-control (optional)
- Compact design provides a space saving and easy to install solution
- High reliability and low energy consumption even in extreme ambient conditions
- Non-ferrous hydraulic circuit maintains the quality of the coolant ensuring stable working conditions, improved productivity and decreased maintenance costs.
1 - 12 of 12 Part Numbers
ICEP002-W
- Maximum Cooling Capacity - 1.7 kW
ICEP003-W
- Maximum Cooling Capacity - 3.3 kW
ICEP005-W
- Maximum Cooling Capacity - 5.2 kW
ICEP007-W
- Maximum Cooling Capacity - 7.8 kW
ICEP010-W
- Maximum Cooling Capacity - 10.8 kW
ICEP014-W
- Maximum Cooling Capacity - 14.6 kW
ICEP020-W
- Maximum Cooling Capacity - 20.3 kW
ICEP024-W
- Maximum Cooling Capacity - 23.6 kW
ICEP030-W
- Maximum Cooling Capacity - 29.7 kW
ICEP040-W
- Maximum Cooling Capacity - 40.6 kW
ICEP050-W
- Maximum Cooling Capacity - 49 kW
ICEP060-W
- Maximum Cooling Capacity - 58.3 kW
1 - 12 of 12 Part Numbers
Specifications
Brand
Connection Type
- Threaded
Electrical Requirements
- 230 V/1-Phase/50 Hz or 400 V/3-Phase/50 Hz
Power Consumption (at 25° C Ambient Temperature)
- 0.77 kW to 13.7 kW
Port Size
- 1/2 to 1-1/2”
Maximum Ambient Temperature
- 118.4° F
- 48° C
Minimum Ambient Temperature (Dependent on Model)
- 14 or 41° F
- -10° or 5° C
Refrigerant Type
- R407C
Number of Axial Fans (Dependent on Model)
- 1 or 2
Compressor Included
- Hermetic Piston or Scroll Compressor
Maximum Operating Temperature
- 86° F
- 30° C
Minimum Operating Temperature
- 41° F
- 5° C
Ingress Protection Rating
- IP33 to IP54
Application
- Precision Cooling of Low viscosity industrial Cooling fluids
Weight
- 88.18 to 1124 lbs
- 40 to 510 kg
Width
- 20.47 to 33.7”
- 520 to 856 mm
Depth
- 19.69 to 77”
- 500 to 1956 mm
Height
- 21.65 to 77”
- 550 to 1956 mm
Specifications Met
- Electromagnetic Directive 2004/108/EC
- Machinery Directive 2006/42/EC
- PED 97/23/EC
Noise Level
- 51 to 52 dBA
Product Type (Dependent on Model)
- Open Hydraulic Circuit or Pressurized Closed Hydraulic Circuit
Documentation
Literature and Reference Materials
- FOCUSED ON Bottling Excellence - Gas Filtration And Separation Solutions For The Soft Drink Bottling Industry pdf 4.8 MB
- FOCUSED ON Compressed Air and Gas Treatment pdf 5.7 MB
- FOCUSED ON Customers' Peace Of Mind - Parker Extended Warranty pdf 2.6 MB
- FOCUSED ON Wine Making - Nitrogen And Temperature Control For The Wine Industry pdf 5.4 MB
- Product Bulletin - Hyperchill Plus - Industrial Water Chiller for Precision Cooling of Low Viscosity Industrial Cooling Fluids pdf 1.0 MB
- Product Bulletin - Hyperchill Plus 60Hz - Industrial Water Chiller for Precision Cooling of Low Viscosity Industrial Cooling Fluids pdf 977 KB
- User Manual - Hyperchill Plus ICEP 002 - 005 (50Hz) Chillers pdf 474 KB
- User Manual - Hyperchill Plus ICEP 002 - 005 (50Hz) Chillers - Appendix Rev 18 pdf 1.1 MB
- User Manual - Hyperchill Plus ICEP 002 (60Hz) Chiller pdf 444 KB
- User Manual - Hyperchill Plus ICEP 003 - 005 (60Hz) Chillers pdf 450 KB
- User Manual - Hyperchill Plus ICEP 007 - 024 (50Hz) Chillers pdf 628 KB
- User Manual - Hyperchill Plus ICEP 007 - 024 (60Hz) Chillers pdf 543 KB
- User Manual - Hyperchill Plus ICEP 007 - 030 (50Hz) Chillers REV20 pdf 5.2 MB
- User Manual - Hyperchill Plus ICEP 007 - 030 (50Hz) Chillers REV21 pdf 5.2 MB