Yodify Product Library
Instantly add the Cable Glands 8161/7, 8161/8 and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Cable Glands 8161/7, 8161/8
Brand: R. STAHL AGR. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter.
They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
Features- For safe cable entry in Ex e and Ex i areas
- Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
- Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
- Suitable for cable diameters from 1 ... 48 mm
- Versions with multi-seal inserts
1 - 12 of 83 Part Numbers
239154
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/7-M12-0601
- Title Product Variant Technical Data - 8161/7-M12-0601 cab.gld. BK Lot50
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 1.00 - 6.00 mm
- Clamping range max. - 6.00 mm
- Clamping range min. - 1.00 mm
- Colour - black
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 18 mm
- Dimension d2 - 7.3 mm
- Dimension d4 - 6.3 mm
- Dimension L - 29 ... 34 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 4.00 J
- Impact strength note - Installation only in areas with a low risk of mechanical damage. Protect cable gland from mechanical damage.
- Lot size - 50
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤10^13 Ω
- Thread length - 9.000 mm
- Thread pitch - 1,5 mm
- Thread size - M12
- Weight - 0.007 kg
- Width across corners - 18.00 mm
- Width across flats - 16,00 mm
239155
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/7-M16-0902
- Title Product Variant Technical Data - 8161/7-M16-0902 cab.gld. BK Lot50
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 2.00 - 9.00 mm
- Clamping range max. - 9.00 mm
- Clamping range min. - 2.00 mm
- Colour - black
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 22 mm
- Dimension d2 - 10.3 mm
- Dimension d4 - 9.3 mm
- Dimension L - 31 ... 37 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 4.00 J
- Impact strength note - Installation only in areas with a low risk of mechanical damage. Protect cable gland from mechanical damage.
- Lot size - 50
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤10^13 Ω
- Thread length - 9.000 mm
- Thread pitch - 1,5 mm
- Thread size - M16
- Weight - 0.009 kg
- Width across corners - 22.00 mm
- Width across flats - 20.00 mm
239156
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Description - 8161/7-M20-1304 4 ... 13 mm², 50 pieces (delivery lot *) )
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/7-M20-1304
- Product Variant - Cable gland
- Title Product Variant Technical Data - 8161/7-M20-1304 cab.gld. BK Lot50
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 4.00 - 13.00 mm
- Clamping range max. - 13.00 mm
- Clamping range min. - 4.00 mm
- Colour - black
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 27 mm
- Dimension d2 - 13.3 mm
- Dimension d4 - 13.3 mm
- Dimension L - 36 ... 43 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 7.00 J
- Lot size - 50
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤10^13 Ω
- Thread length - 10.000 mm
- Thread pitch - 1,5 mm
- Thread size - M20
- Weight - 0.013 kg
- Width across corners - 27.00 mm
- Width across flats - 24.00 mm
239157
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Description - 8161/7-M25-1707 7 ... 17 mm², 50 pieces (delivery lot *) )
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/7-M25-1707
- Product Variant - Cable gland
- Title Product Variant Technical Data - 8161/7-M25-1707 cab.gld. BK Lot50
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 7.00 - 17.00 mm
- Clamping range max. - 17.00 mm
- Clamping range min. - 7.00 mm
- Colour - black
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 32 mm
- Dimension d2 - 17.3 mm
- Dimension d4 - 17.3 mm
- Dimension L - 38 ... 46 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 7.00 J
- Lot size - 50
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤10^13 Ω
- Thread length - 10.000 mm
- Thread pitch - 1,5 mm
- Thread size - M25
- Weight - 0.019 kg
- Width across corners - 32.00 mm
- Width across flats - 29.00 mm
239158
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/7-M32-2109
- Title Product Variant Technical Data - 8161/7-M32-2109 cab.gld. BK Lot25
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 9.00 - 21.00 mm
- Clamping range max. - 21.00 mm
- Clamping range min. - 9.00 mm
- Colour - black
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 40 mm
- Dimension d2 - 21.3 mm
- Dimension d4 - 21.3 mm
- Dimension L - 42 ... 50 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 7.00 J
- Lot size - 25
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤10^13 Ω
- Thread length - 12.000 mm
- Thread pitch - 1,5 mm
- Thread size - M32
- Weight - 0.032 kg
- Width across corners - 40.00 mm
- Width across flats - 36.00 mm
239159
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/7-M40-2812
- Title Product Variant Technical Data - 8161/7-M40-2812 cab.gld. BK Lot10
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 12.00 - 28.00 mm
- Clamping range max. - 28.00 mm
- Clamping range min. - 12.00 mm
- Colour - black
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 51 mm
- Dimension d2 - 28.3 mm
- Dimension d4 - 30 mm
- Dimension L - 52 ... 65 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 7.00 J
- Lot size - 10
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤10^13 Ω
- Thread length - 12.000 mm
- Thread pitch - 1,5 mm
- Thread size - M40
- Weight - 0.068 kg
- Width across corners - 51.00 mm
- Width across flats - 46.00 mm
239160
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/7-M50-3516
- Title Product Variant Technical Data - 8161/7-M50-3516 cab.gld. BK Lot4
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 16.00 - 35.00 mm
- Clamping range max. - 35.00 mm
- Clamping range min. - 16.00 mm
- Colour - black
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 61 mm
- Dimension d2 - 35.3 mm
- Dimension d4 - 40 mm
- Dimension L - 59 ... 72 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 7.00 J
- Lot size - 4
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤10^13 Ω
- Thread length - 14.000 mm
- Thread pitch - 1,5 mm
- Thread size - M50
- Weight - 0.107 kg
- Width across corners - 61.00 mm
- Width across flats - 55.00 mm
239161
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/7-M63-4828
- Title Product Variant Technical Data - 8161/7-M63-4828 cab.gld. BK Lot1
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 28.00 - 48.00 mm
- Clamping range max. - 48.00 mm
- Clamping range min. - 28.00 mm
- Colour - black
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 75 mm
- Dimension d2 - 48.3 mm
- Dimension d4 - 53 mm
- Dimension L - 64 ... 78 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 7.00 J
- Lot size - 1
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤10^13 Ω
- Thread length - 15.000 mm
- Thread pitch - 1,5 mm
- Thread size - M63
- Weight - 0.155 kg
- Width across corners - 75.00 mm
- Width across flats - 68.00 mm
239162
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex i
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/8-M12-0601
- Title Product Variant Technical Data - 8161/8-M12-0601 cab.gld. BU Lot50
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 1.00 - 6.00 mm
- Clamping range max. - 6.00 mm
- Clamping range min. - 1.00 mm
- Colour - blue
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 18 mm
- Dimension d2 - 7.3 mm
- Dimension d4 - 6.3 mm
- Dimension L - 29 ... 34 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 4.00 J
- Impact strength note - Installation only in areas with a low risk of mechanical damage. Protect cable gland from mechanical damage.
- Lot size - 50
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤ 10^13 Ω
- Thread length - 9.000 mm
- Thread pitch - 1,5 mm
- Thread size - M12
- Weight - 0.007 kg
- Width across corners - 18.00 mm
- Width across flats - 16,00 mm
239163
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex i
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/8-M16-0902
- Title Product Variant Technical Data - 8161/8-M16-0902 cab.gld. BU Lot50
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 2.00 - 9.00 mm
- Clamping range max. - 9.00 mm
- Clamping range min. - 2.00 mm
- Colour - blue
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 22 mm
- Dimension d2 - 10.3 mm
- Dimension d4 - 9.3 mm
- Dimension L - 31 ... 37 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 4.00 J
- Impact strength note - Installation only in areas with a low risk of mechanical damage. Protect cable gland from mechanical damage.
- Lot size - 50
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤ 10^13 Ω
- Thread length - 9.000 mm
- Thread pitch - 1,5 mm
- Thread size - M16
- Weight - 0.009 kg
- Width across corners - 22.00 mm
- Width across flats - 20.00 mm
239164
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex i
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Description - 8161/8 Ex i (black with blue cap nut) 8161/8-M20-1304 4 ... 13 mm² 50 pieces (delivery lot*)
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/8-M20-1304
- Product Variant - Cable gland
- Title Product Variant Technical Data - 8161/8-M20-1304 cab.gld. BU Lot50
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 4.00 - 13.00 mm
- Clamping range max. - 13.00 mm
- Clamping range min. - 4.00 mm
- Colour - blue
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 27 mm
- Dimension d2 - 13.3 mm
- Dimension d4 - 13.3 mm
- Dimension L - 36 ... 43 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 7.00 J
- Lot size - 50
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤ 10^13 Ω
- Thread length - 10.000 mm
- Thread pitch - 1,5 mm
- Thread size - M20
- Weight - 0.013 kg
- Width across corners - 27.00 mm
- Width across flats - 24.00 mm
239165
For safe cable entry in Ex e and Ex i areas
Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68
Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut)
Suitable for cable diameters from 1 ... 48 mm
Versions with multi-seal inserts
Ambient Conditions
- Ambient temperature - -40 °C ... +75 °C
- Ambient temperature max. - +75 °C
- Ambient temperature min. - -40 °C
- Use at the height of - < 2000 m
Electrical Data
- Ex version - Ex i
Explosion Protection
- Ambient temperature °C - -40 - 75 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 14 ATEX 1008 X
- ATEX gas certificate - PTB 14 ATEX 1008 X
- Certificate EAC - TS RU S-DE.AA71.B.00083
- Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), Korea (KGS)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC Db
- Dust explosion protection EAC - Ex tb IIIC Db X
- Dust explosion protection IECEx - Ex tb IIIC Db
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection EAC - 1 Ex e II Gb X
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX dust certificate - IECEx PTB 14.0011 X
- IECEX gas certificate - IECEx PTB 14.0011 X
General
- Functional Description - R. STAHL's 8161/7 and 8161/8 series cable entries can be used to safely run cables into Ex e enclosures. They are suitable for cables between 1 and 48 mm in diameter. They are available for Ex e and Ex i circuits – the Ex i version can be distinguished by its blue cap nut. An integrated stopping plug can be used to seal any cable entries that are not being used.
- Highlights - For safe cable entry in Ex e and Ex i areas Can be used at temperatures of between -60 ... +75 °C, degree of protection IP68 Available in Ex e and Ex i versions (Ex i version distinguished by its blue cap nut) Suitable for cable diameters from 1 ... 48 mm Versions with multi-seal inserts
- Product Description - Cable gland With reduction sealing insert
- Product Type - 8161/8-M25-1707
- Title Product Variant Technical Data - 8161/8-M25-1707 cab.gld. BU Lot50
- Variant - standard thread
- Version 3 - with standard thread
- WebCode - 8161B
Mechanical Data
- Armouring type - Unarmoured cable types
- Clamping range - 7.00 - 17.00 mm
- Clamping range max. - 17.00 mm
- Clamping range min. - 7.00 mm
- Colour - blue
- Degree of protection (IP) - IP66
- Degree of protection note - IP68 at 5 bar 30 min. (IP protection according to IEC/EN 60529)
- Dimension d1 - 32 mm
- Dimension d2 - 17.3 mm
- Dimension d4 - 17.3 mm
- Dimension L - 38 ... 46 mm
- Flame retardant - Yes
- Halogen-free - Yes
- Impact strength - 7.00 J
- Lot size - 50
- Material - Polyamide
- Material 2 - glass fibre reinforced
- Material sealing ring - EPDM
- Sealing material - EPDM profile seal
- Self-extinguishing - Yes
- Silicone-free - Yes
- Surface resistance - ≤ 10^13 Ω
- Thread length - 10.000 mm
- Thread pitch - 1,5 mm
- Thread size - M25
- Weight - 0.019 kg
- Width across corners - 32.00 mm
- Width across flats - 29.00 mm
1 - 12 of 83 Part Numbers