PFM 5001 Measuring Instrument
Brand: DanfossThe PFM 5001 has been designed to create hydraulic balance in heating, cooling and domestic hot water systems. It enables measuring of pressure flow and temperatures in a system.
Using differences in pressure the PFM 5001 is capable of turning these two pressures on both sides of a valve into flow. Flow through individual branches of the system can be measured, creating perfect balance in the whole system.
Features- Separated main pressure sensor and converter
- Data analysis based on Android smartphone (not iPhone) or pc via Bluetooth
- Upgradable with additional sensors and routers to extend range
- Possible to choose from different pressure sensors (kPa, bar, etc.)
- Accurate pressure measuring with true differential pressure sensor and 24 bit ADC
- Hydraulic by-pass for exact small differential pressure measuring
- External PT-100 thermometer
- Working with projects
- Programmable autonomous recording mode
- Main sensor powered by rechargeable Li-Ion battery
Specifications
Brand
Accuracy
- ± 1° C (± 1.8° F) - Temperature Measuring Error
- 0.15 % of Range - Reliability
Ambient Temperature Range
- -5° to 50° C (23° to 122° F)
Approvals & Certifications
- CE
- PED
Calibration
- Calibration Validity - 1-Year
Communication
- Baud Rate: 9600 bit/sec - Speed
- Bluetooth
- RF Wireless: 868 MHz (Standard Version), 869.025 MHz (Russian Version)
- Wireless Routers 868 MHz, 500 mW (Standard Versions), 869.025 MHz, 25 mW (Russian Versions)
Environmental Protection
- IP65
Hysteresis
- Hysteresis Error: 0.15 % of Range
Linearity
- 0.15 % of Range
Operating Time
- Maximum
Overpressure & Static Pressure Limits
- Maximum
Power
- Recharge Time: 7 Hours
- RF Transmitter Power: 25 mW
Power Requirement
- Lithium-Ion Batteries 3.6 V 950 mAh
Pressure Range
- psi: 0 to 290 (kPa: 0 to 2,000, bar: 0 to 20)
Process Temperature
- -5° to 90° C (23° to 194° F) (At End of Connection Tubes)
Range
- Radio Range (Open Air) - 0 to 98.4 feet (0 to 30 metres)
- Radio Range in Open Air with 3 Routers - 328.1 feet (100 metres) (Russian Versions)
- Radio Range in Open Air with 3 Routers - 984.3 feet (300 metres) (Standard Versions)
Sensor / Probe Type
- Pt100-Digital - Temperature Probe
Static Pressure
- psi: 290.1 (kPa: 2,000, bar: 20) - Max.
Static Pressure Effect
- psi: ± 0.029 (kPa: ± 0.2, bar: ± 0.002)
Storage Temperature
- -10° to 70° C (14° to 158° F)
Temperature Effect
- 0.25 % of Range
Temperature Range
- -20° to 120° C (-4° to 248° F)