Brand: Eldridge Products, Inc (EPI)

Master-Touch Series 8800MP Flow Meter include a sensor & probe assembly that is inserted into the process gas flow conduit to allow the process gas to flow across the flow sensing elements. 

Our insertion style flowmeters are available with 1/2", 3/4", or 1" OD probes. Tube fittings and ball valve retractor assemblies, with or without a mounting flange, are also available from the factory as options. 

The tube length must be specified upon ordering. Standard lengths range from a minimum of 6" to a maximum of 36". For other probe diameters and lengths, please consult the factory.

Integral style thermal mass flowmeters have all of the electrical components and connections located within one enclosure. This enclosure may be rated for either hazardous environments (MP Series) or for ordinary, non-hazardous environments (MPNH Series), as necessary. 

The enclosure is mounted directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly.

Specifications

Accuracy

  • Accuracy (Including Linearity [Referenced: 21° C (70° F)]: ± (1 % of Reading + 0.5 % of Full Scale + GTC)

Approvals & Certifications

  • ATEX (For use in Hazardous Area Locations, Ta = 0° C to 50° C, IP66, Ex d IIB + H₂ T4 Gb/Ex T IIIC T135° C Db or Ex d IIB + H₂ T3 Gb/Ex T IIIC T200° C Db or Ex d IIB + H₂ T2 Gb/Ex T IIIC T300° C Db, SIRA 12-ATEX-1302)
  • CSA [C-US] (For use in Hazardous Area Locations, Class I, Div. 1, Groups B, C, D, Class II Groups E, F, G Class III: Enclosure Typical 4X, Class I Zone I, AEx d IIB + H₂ IP66, Ex d IIB + H₂ IP66, T2 or T3 or T4 as Marked, Ta = 0° C to 50° C)
  • IECEx (For use in Hazardous Area Locations, T2 or T3 or T4 as Marked, Ta = 0° C to 50° C, Ex d IIB + H₂ T2 to T4 Gb IP66, Ex TD A21 IP66, T135° C to T300° C, IECEx CSA 11.0014)
  • KOSHA (For use in Hazardous Area Locations, Class I Groups B, C, D, Class II Groups E, F, G Class III, Enclosure Typical 4X, Class I Zone I, AEx d IIB=H₂ IP66, Ex d IIB + H₂ T2 to T4 Gb IP66, Ex TD A21 IP66)

Communication

  • Signal Interface: HART
  • Signal Interface: PROFIBUS DP
  • Signal Interface: RS-232
  • Signal Interface: RS-485 Modbus RTU Embedded

Diameter

  • Probe Outer Diameter: 1/2 to 1” (12.7 to 25.4 mm)

Display

  • LCD (Flow Rate, Flow Total, Gas Temperature)

Environmental Protection

  • IP66
  • Typical 4X

Input

  • Input Power Requirement: 115 Vac at 50/60 Hz
  • Input Power Requirement: 230 Vac at 50/60 Hz
  • Input Power Requirement: 24 Vdc at 250 mA

Length

  • 6 to 84” (152.4 to 2,133.6 mm)

NACE & NIST

  • NIST

NPT Connection

  • 3/4” NPT

Output

  • Linear Signal Output: 0-5 Vdc (Flow & Temperature)
  • Linear Signal Output: 4-20 mA (Flow & Temperature)

Power Requirement

  • Flow Transmitter Power Requirement: 5 W, Max.
  • RAM Back-Up: Lithium Battery

Pressure Rating

  • psi: 500 (kPa: 3,447, bar: 34.47) - Max.

Repeatability

  • ± 0.2 % of Full Scale

Response Time

  • Sensor: 1 second to 63 % of Final Value

Sensor, Probe Material

  • Sensor: 316 Stainless Steel Sheath
  • Sensor: Hastelloy C Sheath

Sensor, Probe Type

  • Sensor: RTD

Temperature Coefficient

  • Gas Temperature Coefficient (GTC): 0.02 % of Full Scale/°C

Temperature Range

  • Electronics PCB: -40° to 70° C (-40° to 158° F)
  • Environmental: -40° to 60° C (-40° to 140° F)
  • Gas: -40° to 200° C (-40° to 392° F)
  • Standard Temperature & Pressure (STP): 21° C (70° F) & 29.92” Hg (Air .075 lbs/ft²)

Turndown

  • 100:1 at 1,500 SFPM / 7.6 NMPS Min. Full Scale

Wetted Materials

  • 316 Stainless Steel
  • Hastelloy