Media Converter Series 9721

Brand: R. STAHL AG

The Media Converter is used to convert electrical Ethernet signals (TX) into optical Ethernet signals (FX). The optical Ethernet signals are used for operation in hazardous areas of Zone 0, 1 and 2 with the type of protection Ex op is. 

Therefore, conventional fibre optic cables can also be used in hazardous areas and may be connected and disconnected during operation (hot-swap). The Media Converter (multi mode) is particularly suitable for operation of Remote I/O systems IS 1+ in Zone 1.
Features
  • For 100 Mbit/s Ethernet with inherently safe "op is" fibre optic in Zone 0, 1 or 2
  • Range up to 5 km (multi-mode) or up to 30 km (single-mode)
  • Increased temperature range of -30 to +75 °C
  • Easy commissioning, no configuration required
  • Installation in Zone 2 or in the safe area

1 - 2 of 2 Part Numbers
220381
220381
R. STAHL Media Converter FX Op Is / TX SC for Zone 2 Multi Mode
For 100 Mbit/s Ethernet with inherently safe "op is" fibre optic in Zone 0, 1 or 2



Range up to 5 km (multi-mode) or up to 30 km (single-mode)



Increased temperature range of -30 to +75 °C



Easy commissioning, no configuration required



Installation in Zone 2 or in the safe area

Ambient Conditions

  • Ambient temperature - -30 °C ... +75 °C
  • Ambient temperature max. - +75 °C
  • Ambient temperature min. - -30 °C
  • Relative humidity max. - < 95% (no condensation)
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Current consumption max. - 200 mA
  • Nominal voltage - 24 V DC
  • Polarity reversal protection - yes
  • Power consumption max. - 2.50 W
  • Power supply - 2-pole screw terminal

Device Specific Data

  • operating mode - Half duplex

Electrical Data

  • Connection Ethernet Interface - RJ 45 plug connector
  • FO attenuation - 1 dB / km
  • FO bandwidth - 800 Mhz * km 500 Mhz * km
  • FO Connection type - SC plug connector
  • FO Fibre cross-section - 50/125µm [OS3, OS4] (62,5/125 µm [OM1])
  • FO fibre type - Multi mode
  • FO optical budget - 12 dB
  • FO transmission distance - 4 km, 5 km
  • Interface 1 - 1 Port, 100 Base-FX MM SC
  • Interface 2 - 1 Port, 100 Base-TX Cu, RJ45
  • operating mode - half duplex, full duplex Auto-MDI(X)
  • Transfer rate - 10/100 Mbit/s Auto-Negotiation
  • Transmission distance - Up to 100 m (Cat5e or better)
  • Voltage range DC - 10.8 - 26.4 V DC
  • Wavelength optical interface - 1310 nm

Explosion Protection

  • Ambient temperature °C - -30 - 75 °C
  • Application range (zones) - 2, 22
  • ATEX dust certificate - TÜV 13 ATEX 7316 X
  • ATEX gas certificate - TÜV 13 ATEX 7316 X
  • Certificate EAC - TS RU S-DE.GB04.B.00448
  • Certificates - ATEX (TUR), Canada (FM), EAC (STV), IECEx (TUR), India (PESO), USA (FM)
  • Dust explosion protection ATEX - II (1) D [Ex op is Da] IIIC
  • Dust explosion protection EAC - [Ex op is Da] IIIC X
  • Dust explosion protection IECEx - [Ex op is Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [op is T6 Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [op is T6 Ga] Iic T4 Gc X
  • Gas explosion protection IECEx - Ex nA [op is T6 Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx TUR 13.0014 X
  • IECEX gas certificate - IECEx TUR 13.0014 X
  • Installation - Zone 2, Zone 22 or in the safe area
  • Ship approval - ABS, CCS, ClassNK, DNVGL, RINA

General

  • Description - Media Converter of 10/100 Base-Tx (1 x RJ45 port) to 100 Base-Fx Ex op is (1 x FO port SC); Multi mode (up to 4 km range); Webcode: 9721A
  • Functional Description - The Media Converter is used to convert electrical Ethernet signals (TX) into optical Ethernet signals (FX). The optical Ethernet signals are used for operation in hazardous areas of Zone 0, 1 and 2 with the type of protection Ex op is. Therefore, conventional fibre optic cables can also be used in hazardous areas and may be connected and disconnected during operation (hot-swap). The Media Converter (multi mode) is particularly suitable for operation of Remote I/O systems IS 1+ in Zone 1.
  • Highlights - For 100 Mbit/s Ethernet with inherently safe "op is" fibre optic in Zone 0, 1 or 2 Range up to 5 km (multi-mode) or up to 30 km (single-mode) Increased temperature range of -30 to +75 °C Easy commissioning, no configuration required Installation in Zone 2 or in the safe area
  • Product Description - Media converter FX op is / TX SC for Zone 2 Multi mode
  • Product Type - 9721/13-11-14
  • Product Variant - Media converter FX op is / TX SC for Zone 2
  • Title Product Variant Technical Data - 9721/13-11-14 Converter FXopis/TX SC MM
  • WebCode - 9721A

Mechanical Data

  • Connection cross section max. - 2.50 mm²
  • Connection cross-section min. - 0.08 mm²
  • Degree of protection (IP) - IP20
  • Enclosure material - Stainless steel, powder-coated
  • Pollutant class - Corresponds to G3
  • Weight - 0.240 kg

Mounting / Installation

  • Mounting position - vertical horizontal
  • Mounting type - On 35 mm DIN rail
  • Mounting type 2 - wall mounting
  • stripping length - 7 mm
  • Tightening torque - 0.50 N/m

Safety Data

  • Max. FO radiant power - ≤ 15 mW
220382
220382
R. STAHL Media Converter FX Op Is / TX SC for Zone 2 Single Mode
For 100 Mbit/s Ethernet with inherently safe "op is" fibre optic in Zone 0, 1 or 2



Range up to 5 km (multi-mode) or up to 30 km (single-mode)



Increased temperature range of -30 to +75 °C



Easy commissioning, no configuration required



Installation in Zone 2 or in the safe area

Ambient Conditions

  • Ambient temperature - -30 °C ... +75 °C
  • Ambient temperature max. - +75 °C
  • Ambient temperature min. - -30 °C
  • Relative humidity max. - < 95% (no condensation)
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Current consumption max. - 200 mA
  • Nominal voltage - 24 V DC
  • Polarity reversal protection - yes
  • Power consumption max. - 2.50 W
  • Power supply - 2-pole screw terminal

Device Specific Data

  • operating mode - Half duplex

Electrical Data

  • Connection Ethernet Interface - RJ 45 plug connector
  • FO attenuation - 0.3 dB / km
  • FO bandwidth - 3.5 ps / nm * km
  • FO Connection type - SC plug connector
  • FO Fibre cross-section - 9/125 µm (OS1, OS2)
  • FO fibre type - Single mode
  • FO optical budget - 16 dB
  • FO transmission distance - 30 km
  • Interface 1 - 1 Port, 100 Base-FX SM SC
  • Interface 2 - 1 Port, 100 Base-TX Cu, RJ45
  • operating mode - half duplex, full duplex Auto-MDI(X)
  • Transfer rate - 10/100 Mbit/s Auto-Negotiation
  • Transmission distance - Up to 100 m (Cat5e or better)
  • Voltage range DC - 10.8 - 26.4 V DC
  • Wavelength optical interface - 1300 nm

Explosion Protection

  • Ambient temperature °C - -30 - 75 °C
  • Application range (zones) - 2, 22
  • ATEX dust certificate - TÜV 13 ATEX 7316 X
  • ATEX gas certificate - TÜV 13 ATEX 7316 X
  • Certificate EAC - TS RU S-DE.GB04.B.00448
  • Certificates - ATEX (TUR), Canada (FM), EAC (STV), IECEx (TUR), India (PESO), USA (FM)
  • Dust explosion protection ATEX - II (1) D [Ex op is Da] IIIC
  • Dust explosion protection EAC - [Ex op is Da] IIIC X
  • Dust explosion protection IECEx - [Ex op is Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [op is T6 Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [op is T6 Ga] Iic T4 Gc X
  • Gas explosion protection IECEx - Ex nA [op is T6 Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx TUR 13.0014 X
  • IECEX gas certificate - IECEx TUR 13.0014 X
  • Installation - Zone 2, Zone 22 or in the safe area
  • Ship approval - ABS, CCS, ClassNK, DNVGL, RINA

General

  • Description - Media Converter from 10/100Base-TX (1 x RJ-45 port) to 100Base-FX "Ex op is" (1 x FO port SC); single mode (up to 30 km range); WebCode: 9721A
  • Functional Description - The Media Converter is used to convert electrical Ethernet signals (TX) into optical Ethernet signals (FX). The optical Ethernet signals are used for operation in hazardous areas of Zone 0, 1 and 2 with the type of protection Ex op is. Therefore, conventional fibre optic cables can also be used in hazardous areas and may be connected and disconnected during operation (hot-swap). The Media Converter (multi mode) is particularly suitable for operation of Remote I/O systems IS 1+ in Zone 1.
  • Highlights - For 100 Mbit/s Ethernet with inherently safe "op is" fibre optic in Zone 0, 1 or 2 Range up to 5 km (multi-mode) or up to 30 km (single-mode) Increased temperature range of -30 to +75 °C Easy commissioning, no configuration required Installation in Zone 2 or in the safe area
  • Product Description - Media converter FX op is / TX SC for Zone 2 Single mode
  • Product Type - 9721/13-11-54
  • Product Variant - Media converter FX op is / TX SC for Zone 2
  • Title Product Variant Technical Data - 9721/13-11-54 Converter FXopis/TX SC SM
  • WebCode - 9721A

Mechanical Data

  • Connection cross section max. - 2.50 mm²
  • Connection cross-section min. - 0.08 mm²
  • Degree of protection (IP) - IP20
  • Enclosure material - Stainless steel, powder-coated
  • Pollutant class - Corresponds to G3
  • Weight - 0.240 kg

Mounting / Installation

  • Mounting position - horizontal vertical
  • Mounting type - On 35 mm DIN rail
  • Mounting type 2 - wall mounting
  • stripping length - 7 mm
  • Tightening torque - 0.50 N/m

Safety Data

  • Max. FO radiant power - ≤ 15 mW