Yodify Product Library
Instantly add the DLM4000 Mixed Signal Oscilloscope and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

DLM4000 Mixed Signal Oscilloscope

Brand: Yokogawa Electric Corporation

The DLM4000 is an eight-channel mixed-signal oscilloscope suitable to test and debugging applications in the embedded systems, power electronics, mechatronics, and automotive sectors. 

Available in both 350 MHz and 500 MHz models, the 2.5 GSa/sec DLM4000 features eight analog input channels. 

The eighth input channel features Flex MSO which converts to a 8-bit logic analyzer at the push of a button; add sixteen additional logic analyzer inputs as an option, for 24-bit logic analysis.

Advanced measurement and analysis features such as power analysis and serial-bus analysis, digital filtering, user-defined math, and super-long record lengths (up to 250 Mega Points) make the DLM4000 a super powerful engineering tool. 

High-resolution 12.1-inch LCD display, compact landscape format, ergonomic and friendly user-interface make it easy to use.
Features
  • SENT Auto Setup trigger quickly detects and displays decoded data
  • Extensive trigger suite includes analog, logic and SENT specifc trigger conditions
  • Independent dual-zoom windows for displaying analog and SENT waveforms
  • Display decoded Fast and Slow Channels simultaneously in real-time
  • Deep memory up to 250MPts for acquisitions as long as 100sec, even when the clock period is 3 us.
  • Decode message frames as Nibbles or User-Defned format
  • Zoom search function for specifc data patterns or errors
  • Store decoded data in CSV fle format to PC or internal memory
  • Trend the data on up to 4 SENT waveforms
  • Supports version 2010 and later

Specifications

Accuracy

  • ± (1 % of Setting + 0.2 mV) for 2-50 mV/div - Offset Voltage Accuracy
  • ± (1 % of Setting + 2 mV) for 100-500 mV/div - Offset Voltage Accuracy
  • ± (1 % of Setting + 20 mV) for 1-10 V/div - Offset Voltage Accuracy
  • ± (1.5 % of 8 Div + Offset Voltage Accuracy) - DC Accuracy
  • ± 0.002 % - Time Base Accuracy

Approvals & Certifications

  • AS
  • BS
  • CSA
  • IEC 61000-3-2 Edition 2.2, EN 61000-3-2 (2,000), IEC 61000-4-7 Edition 2
  • IEEE
  • NBR
  • UL
  • VDE

Bandwidth

  • -34 dB Typical - Max.
  • 8 to 200,000 kHz - Bandwidth Limit

Channels

  • 7 Analog Channels + 24-bits Logic - Input Channels (DLM4058)
  • 7 Analog Channels + 8-bits Logic - Input Channels (DLM4038)
  • 8 Analog Channels + 16-bits Logic - Input Channels (DLM4058)
  • 8 Analog Channels + 8-bits Logic - Input Channels (DLM4038)

Communication

  • CAN Bus
  • Ethernet
  • FlexRay
  • I²C
  • RS-232
  • SENT Protocol
  • SPI
  • UART

Consumption

  • 250 VA - Max.

Display

  • 12.1-inch TFT Color Liquid Crystal Display, 1024 x 768 (XGA)

Electrical Connectors

  • 3-Wire - Trigger Typicals
  • 4-Wire - Trigger Typicals
  • RJ45 Connector
  • USB

Frequency

  • 100 MHz - Max.
  • 250 MHz - Max.
  • 300 MHz for 20-50 mV/div & 2-5 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM4038)
  • 350 MHz for 100 mV-100 V/div & 10-500 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM4038)
  • 400 MHz for 20-50 mV/div & 2-5 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM4058)
  • 500 MHz for 100 mV-100 V/div & 10 mV-500 mV/div - 1 Megaohm (When Using Passive Probe) & 50 ohms (DLM4058)

Function

  • Auto Setup Control
  • CAN Bus Signal Analysis
  • CAN FD Bus Signal
  • Computation & Analysis
  • FlexRay Bus Signal Analysis
  • I²C Bus Signal Analysis
  • LIN Bus Signal Analysis
  • Reference
  • Replay
  • Search
  • SENT Signal Analysis
  • UART Bus Signal Analysis
  • Zoom

Input

  • ± 40 V - Input Range & Threshold Level Setting Range for Model 701988
  • ± 40 V (DC + AC Peak) - Max.
  • 150 Vrms - Max.
  • 28 Vrms - Max.
  • 300 mV Peak-to-Peak - Min. Input Voltage (701989)
  • 500 mV Peak-to-Peak - Min. Input Voltage (701988)
  • AC & DC - Input Coupling Setting
  • Channel 1 to Channel 8 - Analog Input
  • DC 50 ohms - Input Coupling Setting
  • Ground - Input Coupling Setting
  • Must Not Exceed 5 Vrms or 10 V Peak - Max.
  • Threshold ± 6 V - Input Range Threshold Level Setting Range for Model 701989

Input Impedance

  • 1 Megaohm, ± 1 %, Approximately 20 PF - Analog Input
  • 50 ohms, ± 1 % (VSWR 1.4 or Less, DC to 500 MHz) - Analog Input

Measuring Time

  • 0.2 to 5,000 seconds - Max.
  • 100 milliseconds to 100 seconds - Accumulation Time

Operating Temperature

  • 5° to 40° C (41° to 104° F)

Output Noise

  • 0.05 Div RMS Typical - Residual Noise Level
  • 0.4 mV RMS - Residual Noise Level

Resolution

  • 0.05 V - Setting Resolution
  • 8-bits (25 LSB/div) - A/D Resolution
  • Maximum

Sample Rate

  • 62.5 KS/s to 1.25 GS/s

Sensitivity

  • 2 mV/div-10 V/div (Steps of 1-2-5) - Voltage Axis Sensitivity Setting Range for 1 Megaohm
  • 2-500 mV/div (Steps of 1-2-5) - Voltage Axis Sensitivity Setting Range for 50 ohms

Supply Voltage

  • 100-240 Vac, 50/60 Hz - Rated Supply Voltage
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more