Yodify Product Library
Instantly add the Single-Channel Safety Barriers Series 9001 and 50,000+ more product series to yourĀ store or catalogĀ Ā 
Book Your Demo and See How
or create your store

Single-Channel Safety Barriers Series 9001

Brand: R. STAHL AG

The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. 

The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. 

The devices are incredibly robust and require little space. 

The back-up fuse is a convenient feature as it is standardized for all variants.
Features
  • For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
  • Compact, space-saving devices that are easy to install on a DIN rail
  • Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

1 - 12 of 74 Part Numbers
158301
158301
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - ± 12.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 223.00 Ω
  • Maximum output current I max - 53 mA
  • Min. resistance R min - 198.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - Alternative potential
  • Rated operational voltage DC - 12.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/02-175-100-101
  • Product Variant - Series 9001/02, Single-channel safety barriers for alternating polarity
  • Title Product Variant Technical Data - 9001/02-175-100-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 100.0 mA
  • Max. permissible external capacitance C o for IIB - 1.970 μF
  • Max. permissible external capacitance C o for IIC - 0.339 μF
  • Max. permissible external inductance L o for IIB - 15.000 mH
  • Max. permissible external inductance L o for IIC - 4.000 mH
  • Max. Power P o - 437.500 mW
  • Max. Voltage U o - 17.50 V
158312
158312
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - ± 16.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 167.00 Ω
  • Maximum output current I max - 95 mA
  • Min. resistance R min - 149.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - Alternative potential
  • Rated operational voltage DC - 16.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/02-196-150-101
  • Product Variant - Series 9001/02, Single-channel safety barriers for alternating polarity
  • Title Product Variant Technical Data - 9001/02-196-150-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 150.0 mA
  • Max. permissible external capacitance C o for IIB - 1.470 μF
  • Max. permissible external capacitance C o for IIC - 0.235 μF
  • Max. permissible external inductance L o for IIB - 7.000 mH
  • Max. permissible external inductance L o for IIC - 1.300 mH
  • Max. Power P o - 735.000 mW
  • Max. Voltage U o - 19.60 V
158317
158317
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - ± 24.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 357.00 Ω
  • Maximum output current I max - 67 mA
  • Min. resistance R min - 320.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - Alternative potential
  • Rated operational voltage DC - 24.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - Acceleration sensor
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/02-280-090-101
  • Product Variant - Series 9001/02, Single-channel safety barriers for alternating polarity
  • Title Product Variant Technical Data - 9001/02-280-090-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 90.0 mA
  • Max. permissible external capacitance C o for IIB - 0.650 μF
  • Max. permissible external capacitance C o for IIC - 0.083 μF
  • Max. permissible external inductance L o for IIB - 14.000 mH
  • Max. permissible external inductance L o for IIC - 2.200 mH
  • Max. Power P o - 630.000 mW
  • Max. Voltage U o - 28.00 V
158322
158322
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - 1.00 ... 3.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 49.00 Ω
  • Maximum output current I max - 61 mA
  • Min. resistance R min - 42.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - negative potential

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/00-050-150-101
  • Product Variant - Series 9001/00, Single-channel safety barriers for negative polarity
  • Title Product Variant Technical Data - 9001/00-050-150-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 150.0 mA
  • Max. permissible external capacitance C o for IIB - 1000.000 μF
  • Max. permissible external capacitance C o for IIC - 100.000 μF
  • Max. permissible external inductance L o for IIB - 7.000 mH
  • Max. permissible external inductance L o for IIC - 1.300 mH
  • Max. Power P o - 187.500 mW
  • Max. Voltage U o - 5.00 V
158328
158328
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - 1.00 ... 3.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 49.00 Ω
  • Maximum output current I max - 20 - 61 mA
  • Min. resistance R min - 42.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - positive potential

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/01-050-150-101
  • Product Variant - Series 9001/01, Single-channel safety barriers for positive polarity
  • Title Product Variant Technical Data - 9001/01-050-150-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 150.0 mA
  • Max. permissible external capacitance C o for IIB - 1000.000 μF
  • Max. permissible external capacitance C o for IIC - 100.000 μF
  • Max. permissible external inductance L o for IIB - 7.000 mH
  • Max. permissible external inductance L o for IIC - 1.300 mH
  • Max. Power P o - 187.500 mW
  • Max. Voltage U o - 5.00 V
158329
158329
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - ± 36.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 508.00 Ω
  • Maximum output current I max - 70 mA
  • Min. resistance R min - 456.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - Alternative potential
  • Rated operational voltage DC - 36.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/02-412-095-101
  • Product Variant - Series 9001/02, Single-channel safety barriers for alternating polarity
  • Title Product Variant Technical Data - 9001/02-412-095-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 95.0 mA
  • Max. permissible external capacitance C o for IIB - 0.287 μF
  • Max. permissible external inductance L o for IIB - 9.000 mH
  • Max. Power P o - 979.000 mW
  • Max. Voltage U o - 41.20 V
158333
158333
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - 6.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 28.00 Ω
  • Maximum output current I max - 110 mA
  • Min. resistance R min - 24.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - negative potential
  • Rated operational voltage DC - 6.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/00-083-442-101
  • Product Variant - Series 9001/00, Single-channel safety barriers for negative polarity
  • Title Product Variant Technical Data - 9001/00-083-442-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 442.0 mA
  • Max. permissible external capacitance C o for IIB - 73.000 μF
  • Max. permissible external capacitance C o for IIC - 7.200 μF
  • Max. permissible external inductance L o for IIB - 0.500 mH
  • Max. permissible external inductance L o for IIC - 0.100 mH
  • Max. Power P o - 917.200 mW
  • Max. Voltage U o - 8.30 V
158338
158338
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - 6.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 28.00 Ω
  • Maximum output current I max - 110 mA
  • Min. resistance R min - 24.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - positive potential
  • Rated operational voltage DC - 6.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/01-083-442-101
  • Product Variant - Series 9001/01, Single-channel safety barriers for positive polarity
  • Title Product Variant Technical Data - 9001/01-083-442-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 442.0 mA
  • Max. permissible external capacitance C o for IIB - 73.000 μF
  • Max. permissible external capacitance C o for IIC - 7.200 μF
  • Max. permissible external inductance L o for IIB - 0.500 mH
  • Max. permissible external inductance L o for IIC - 0.100 mH
  • Max. Power P o - 917.200 mW
  • Max. Voltage U o - 8.30 V
158339
158339
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - 24.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 462.00 Ω
  • Maximum output current I max - 51 mA
  • Min. resistance R min - 415.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - positive potential
  • Rated operational voltage DC - 24.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - 2-wire transmitter, grounded speed sensor
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/01-280-075-101
  • Product Variant - Series 9001/01, Single-channel safety barriers for positive polarity
  • Title Product Variant Technical Data - 9001/01-280-075-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 75.0 mA
  • Max. permissible external capacitance C o for IIB - 0.650 μF
  • Max. permissible external capacitance C o for IIC - 0.083 μF
  • Max. permissible external inductance L o for IIB - 21.000 mH
  • Max. permissible external inductance L o for IIC - 3.300 mH
  • Max. Power P o - 525.000 mW
  • Max. Voltage U o - 28.00 V
158344
158344
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - 24.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 375.00 Ω
  • Maximum output current I max - 64 mA
  • Min. resistance R min - 340.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - negative potential
  • Rated operational voltage DC - 24.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Japan (TIIS), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/00-280-085-101
  • Product Variant - Series 9001/00, Single-channel safety barriers for negative polarity
  • Title Product Variant Technical Data - 9001/00-280-085-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 85.0 mA
  • Max. permissible external capacitance C o for IIB - 0.650 μF
  • Max. permissible external capacitance C o for IIC - 0.083 μF
  • Max. permissible external inductance L o for IIB - 16.000 mH
  • Max. permissible external inductance L o for IIC - 2.400 mH
  • Max. Power P o - 595.000 mW
  • Max. Voltage U o - 28.00 V
158350
158350
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - 6.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 964.00 Ω
  • Maximum output current I max - 6 mA
  • Min. resistance R min - 870.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - positive potential
  • Rated operational voltage DC - 6.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - variable
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/01-086-010-101
  • Product Variant - Series 9001/01, Single-channel safety barriers for positive polarity
  • Title Product Variant Technical Data - 9001/01-086-010-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 10.0 mA
  • Max. permissible external capacitance C o for IIB - 55.000 μF
  • Max. permissible external capacitance C o for IIC - 6.200 μF
  • Max. permissible external inductance L o for IIB - 1000.000 mH
  • Max. permissible external inductance L o for IIC - 300.000 mH
  • Max. Power P o - 21.500 mW
  • Max. Voltage U o - 8.60 V
158351
158351
R. STAHL Single-Channel Safety Barriers
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more

Compact, space-saving devices that are easy to install on a DIN rail

Quick to install as barriers can be simultaneously snapped onto rail and connected to PE

Ambient Conditions

  • Ambient temperature - -20 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -20 °C
  • Relative humidity max. - 95% on average, no condensation
  • Storage temperature - -20 °C ... +75 °C
  • Storage temperature max. - +75 °C
  • Storage temperature min. - -20 °C
  • Temperature influence - ≤ 0,25 %/10K

Auxiliary power

  • Nominal voltage - 24.00 V
  • Power supply - Controlled, nominal voltage

Electrical Data

  • Leakage current I leck for U N - ≤ 2 µA
  • Leakage current I leck for U N 2 - (Unless specified otherwise)
  • Max. resistance R max - 375.00 Ω
  • Maximum output current I max - 64 mA
  • Min. resistance R min - 340.00 Ω
  • Number of channels - 1
  • Ohmic current limiting using frequency - ≤ 50 kHz
  • Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
  • Potential - positive potential
  • Rated operational voltage DC - 24.00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - PTB 01 ATEX 2088 X
  • ATEX gas certificate - PTB 01 ATEX 2088 X
  • Certificate EAC - TS RU C-DE.ГБ04.B.00652
  • Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), EAC (STV), IECEx (PTB), Japan (TIIS), Korea (KGS), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
  • IECEX dust certificate - IECEx PTB 09.0001X
  • IECEX gas certificate - IECEx PTB 09.0001X
  • Installation - in Zone 2, Division 2 and in safe area

General

  • Description - single channel
  • Functional Description - The 9001 series INTRINSPAK single-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require little space. The back-up fuse is a convenient feature as it is standardised for all variants.
  • Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
  • Particularly suitable for - 2-wire transmitter, grounded acceleration sensor
  • Product Description - Single-channel safety barriers
  • Product Type - 9001/01-280-085-101
  • Product Variant - Series 9001/01, Single-channel safety barriers for positive polarity
  • Title Product Variant Technical Data - 9001/01-280-085-101 safety barrier
  • WebCode - 9001A

Mechanical Data

  • Clamping range max. - 1.50 mm²
  • Connection cross-section - 4.0 mm²
  • Degree of protection (IP) - IP40
  • Degree of protection note - according to IEC 60529
  • Enclosure material - Polyamide 6GF
  • Length - 12.000 mm
  • Mounting depth - 72.000 mm
  • Number of connection terminals - 4
  • Terminal degree of protection (IP) - IP20
  • Type of connection cable - Finely stranded, solid
  • Weight - 0.110 kg
  • Width - 103.000 mm

Mounting / Installation

  • Connection type - 2 PA

Safety Data

  • Max. Current I o - 85.0 mA
  • Max. permissible external capacitance C o for IIB - 0.650 μF
  • Max. permissible external capacitance C o for IIC - 0.083 μF
  • Max. permissible external inductance L o for IIB - 16.000 mH
  • Max. permissible external inductance L o for IIC - 2.400 mH
  • Max. Power P o - 595.000 mW
  • Max. Voltage U o - 28.00 V