Yodify Product Library
Instantly add the Hazardous Area Radio - Metal Housing and 50,000+ more product series to yourĀ store or catalogĀ Ā 
Book Your Demo and See How
or create your store

Hazardous Area Radio - Metal Housing

Brand: Banner Engineering

Hazardous area radios are a state-of-the-art combination of wireless communication, battery technology and intrinsically safe electronics. 

Networks are formed using DX80 Performance Gateways installed beyond the hazardous area and one or more Nodes operating in the same frequency band.
Features
  • All models are certified for operation in Class I, Division 1 and ATEX Zone 0 locations.
  • Both 900 MHz 150 mW and 2.4 GHz 63 mW models are available.
  • Discrete, Analog, and temperature input types are available.
  • Battery-based power supply provides power for third-party 4 to 20 mA and NAMUR process sensors.
  • Polycarbonate housing devices require the DX81H Battery Module.

1 - 12 of 19 Part Numbers
DX99N2X1S0N0R4X0D0
DX99N2X1S0N0R4X0D0
  • Application: Temperature Input - Yes
  • Device Type - Node
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - RTD: 4 inputs
  • Input/output - RTD
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S0N0R4X0D0-NB
DX99N2X1S0N0R4X0D0-NB
  • Application: Temperature Input - Yes
  • Device Type - Node
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - RTD: 4 inputs
  • Input/output - RTD
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S1N0M3X0D5
DX99N2X1S1N0M3X0D5
  • Analog Inputs - Yes
  • Application: Temperature Input - Yes
  • Device Type - Node
  • Discrete Inputs - Yes
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - 1 Analog, 1 sinking discrete
  • Input/output - Analog & Discrete
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S1S0V2X0D4
DX99N2X1S1S0V2X0D4
  • Device Type - Node
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - 1 Modbus
  • Input/output - Serial (Modbus)
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - Yes
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • RS-485 - Yes
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S2N0B2X0D0
DX99N2X1S2N0B2X0D0
  • Analog Inputs - Yes
  • Device Type - Node
  • Discrete Inputs - Yes
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - Bridge: 2 Inputs
  • Input/output - Analog & Discrete
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S2N0M2X0D1
DX99N2X1S2N0M2X0D1
  • Analog Inputs - Yes
  • Device Type - Node
  • Discrete Inputs - Yes
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - 2 Discrete, 2 0-20 mA Analog
  • Input/output - Analog & Discrete
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S2N0M2X0D2
DX99N2X1S2N0M2X0D2
  • Analog Inputs - Yes
  • Device Type - Node
  • Discrete Inputs - Yes
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - 2 Discrete, 2 0-20 mA Analog
  • Input/output - Analog & Discrete
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S2N0T4X0D0
DX99N2X1S2N0T4X0D0
  • Application: Temperature Input - Yes
  • Device Type - Node
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - Thermocouple (3 inputs, 1 thermistor)
  • Input/output - Thermocouple
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S2N0V2X0D1
DX99N2X1S2N0V2X0D1
  • Analog Inputs - Yes
  • Device Type - Node
  • Discrete Inputs - Yes
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - 2 Discrete, 2 0-10 Volt Analog
  • Input/output - Analog & Discrete
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N2X1S2N0V2X0D2
DX99N2X1S2N0V2X0D2
  • Analog Inputs - Yes
  • Device Type - Node
  • Discrete Inputs - Yes
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - 2 Discrete, 2 0-10 Volt Analog
  • Input/output - Analog & Discrete
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 2.4 GHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N9X1S0N0R4X0D0
DX99N9X1S0N0R4X0D0
  • Application: Temperature Input - Yes
  • Device Type - Node
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - RTD: 4 inputs
  • Input/output - RTD
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 900 MHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
DX99N9X1S1N0M3X0D5
DX99N9X1S1N0M3X0D5
  • Analog Inputs - Yes
  • Application: Temperature Input - Yes
  • Device Type - Node
  • Discrete Inputs - Yes
  • Environmental Rating (IP) - IP68
  • Feature: Hazardous Area - Yes
  • Hazardous/Intrinsically Safe Classification - Class I, Division 1/Zone 0; Class II, Division 1; Class III, Division 1; ATEX Zone 0/Zone 20
  • Housing Style - Integrated Battery
  • Input Details - 1 Analog, 1 sinking discrete
  • Input/output - Analog & Discrete
  • Intrinsically Safe - Yes
  • LCD Display - Yes
  • Max Operating Temperature ( °C) - 80
  • Min Operating Temperature ( °C) - -20
  • Modbus RTU - No
  • Point-to-Multipoint Topology - Yes
  • Point-to-Point Topology - Yes
  • Power Supply - D-Cell Lithium
  • Radio Frequency - 900 MHz
  • Relative Humidity - 95%
  • Star Topology - Yes
  • Tree Topology - No
  • Wireless - Yes
1 - 12 of 19 Part Numbers
Instantly populate your store or catalogĀ 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more