Brand: R. STAHL AG9419 series bus carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for four or eight segments with simplex supply and for four segments with redundant supply.
Softing FG-200 HSE/FF Modbus linking devices and pnGate PA can be integrated into this version, and can link up to eight H1 segments to the Modbus TCP protocol or PROFINET.
Features- Time- and cost-saving installation on DIN rails or mounting plates
- high availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors
- Special slot for FG-200 linking device for the Softing pnGate PA and for DCM series 9415 for online transmission of physical layer diagnostics
1 - 3 of 3 Part Numbers
250240
Time- and cost-saving installation on DIN rails or mounting plates
high availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors
Special slot for FG-200 linking device for the Softing pnGate PA and for DCM series 9415 for online transmission of physical layer diagnostics
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 24 V DC
- Redundant supply - yes, diode-decoupled
Electrical Data
- Error detection Diagnostic - Contact "Dia" (35 V /100 mA) closed in good conditions
- Error detection Power Fail (pri / red) - Contact "PF" (35 V /100 mA) closed in good conditions
- Number of segments - 4
- Trunk supply - simplex
Explosion Protection
- Application range (zones) - 2
- ATEX gas certificate - BVS 09 ATEX E 100 X
- Certificates - ATEX (BVS), Brazil (ULB), EAC (Sertium), IECEx (BVS), India (PESO)
- Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
- Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
- IECEX gas certificate - IECEx BVS 09.0042X
General
- Functional Description - 9419 series bus carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for four or eight segments with simplex supply and for four segments with redundant supply. Softing FG-200 HSE/FF Modbus linking devices and pnGate PA can be integrated into this version, and can link up to eight H1 segments to the Modbus TCP protocol or PROFINET.
- Highlights - Time- and cost-saving installation on DIN rails or mounting plates high availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors Special slot for FG-200 linking device for the Softing pnGate PA and for DCM series 9415 for online transmission of physical layer diagnostics
- Product Description - ISbus fieldbus technology bus-Carrier for linking device
- Product Type - 9419/04F-LD1-01E1
- Title Product Variant Technical Data - 9419/04F-LD1-01E1 4SEG bus-carrier
- WebCode - 9419C
Mechanical Data
- Connection DCM - see operating instructions Series 9415
- Connection Linking Device - Fieldbuses automatically by clicking into place in the slot provided. Auxiliary power automatically by clicking into place on the slot provided. Ethernet (HSE / Modbus TCP), PROFINET through RJ45 connector
- Connection Shield - Shield terminal or plug connector or shield bus with strain relief
- Connection Trunk - to the terminals of the bus-Carrier or of the fieldbus power supply
- Number of slots - 4 FPS + 1 LD + 1 DCM
- Weight - 0.712 kg
250241
Time- and cost-saving installation on DIN rails or mounting plates
high availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors
Special slot for FG-200 linking device for the Softing pnGate PA and for DCM series 9415 for online transmission of physical layer diagnostics
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 24 V DC
- Redundant supply - yes, diode-decoupled
Electrical Data
- Error detection Diagnostic - Contact "Dia" (35 V /100 mA) closed in good conditions
- Error detection Power Fail (pri / red) - Contact "PF" (35 V /100 mA) closed in good conditions
- Number of segments - 4
- Trunk supply - redundant
Explosion Protection
- Application range (zones) - 2
- ATEX gas certificate - BVS 09 ATEX E 100 X
- Certificates - ATEX (BVS), Brazil (ULB), EAC (Sertium), IECEx (BVS), India (PESO)
- Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
- Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
- IECEX gas certificate - IECEx BVS 09.0042X
General
- Functional Description - 9419 series bus carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for four or eight segments with simplex supply and for four segments with redundant supply. Softing FG-200 HSE/FF Modbus linking devices and pnGate PA can be integrated into this version, and can link up to eight H1 segments to the Modbus TCP protocol or PROFINET.
- Highlights - Time- and cost-saving installation on DIN rails or mounting plates high availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors Special slot for FG-200 linking device for the Softing pnGate PA and for DCM series 9415 for online transmission of physical layer diagnostics
- Product Description - ISbus fieldbus technology bus-Carrier for linking device
- Product Type - 9419/04R-LD1-02E1
- Title Product Variant Technical Data - 9419/04R-LD1-02E1 4SEG bus-carrier
- WebCode - 9419C
Mechanical Data
- Connection DCM - see operating instructions Series 9415
- Connection Linking Device - Fieldbuses automatically by clicking into place in the slot provided. Auxiliary power automatically by clicking into place on the slot provided. Ethernet (HSE / Modbus TCP), PROFINET through RJ45 connector
- Connection Shield - Shield terminal or plug connector or shield bus with strain relief
- Connection Trunk - to the terminals of the bus-Carrier or of the fieldbus power supply
- Number of slots - 8 FPS + 2 LD + 1 DCM
- Weight - 0.980 kg
250242
Time- and cost-saving installation on DIN rails or mounting plates
high availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors
Special slot for FG-200 linking device for the Softing pnGate PA and for DCM series 9415 for online transmission of physical layer diagnostics
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
Auxiliary power
- Nominal voltage - 24 V DC
- Redundant supply - yes, diode-decoupled
Electrical Data
- Error detection Diagnostic - Contact "Dia" (35 V /100 mA) closed in good conditions
- Error detection Power Fail (pri / red) - Contact "PF" (35 V /100 mA) closed in good conditions
- Number of segments - 8
- Trunk supply - simplex
Explosion Protection
- Application range (zones) - 2
- ATEX gas certificate - BVS 09 ATEX E 100 X
- Certificates - ATEX (BVS), Brazil (ULB), EAC (Sertium), IECEx (BVS), India (PESO)
- Gas explosion protection ATEX - II 3 G Ex nA nC IIC T4 Gc
- Gas explosion protection IECEx - Ex nA nC IIC T4 Gc
- IECEX gas certificate - IECEx BVS 09.0042X
General
- Functional Description - 9419 series bus carriers allow 9412 series fieldbus power supplies for FF H1 segments to be installed quickly and securely. Variants are available for four or eight segments with simplex supply and for four segments with redundant supply. Softing FG-200 HSE/FF Modbus linking devices and pnGate PA can be integrated into this version, and can link up to eight H1 segments to the Modbus TCP protocol or PROFINET.
- Highlights - Time- and cost-saving installation on DIN rails or mounting plates high availability thanks to redundant auxiliary power supply with signalling contact and separate signalling contact for segment errors Special slot for FG-200 linking device for the Softing pnGate PA and for DCM series 9415 for online transmission of physical layer diagnostics
- Product Description - ISbus fieldbus technology bus-Carrier for linking device
- Product Type - 9419/08F-LD1-01E1
- Title Product Variant Technical Data - 9419/08F-LD1-01E1 8SEG bus-carrier
- WebCode - 9419C
Mechanical Data
- Connection DCM - see operating instructions Series 9415
- Connection Linking Device - Fieldbuses automatically by clicking into place in the slot provided. Auxiliary power automatically by clicking into place on the slot provided. Ethernet (HSE / Modbus TCP) through RJ45 connector
- Connection Shield - Shield terminal or plug connector or shield bus with strain relief
- Connection Trunk - to the terminals of the bus-Carrier or of the fieldbus power supply
- Number of slots - 8 FPS + 2 LD + 1 DCM
- Weight - 1.010 kg