Brand: Burkert Fluid Control SystemsThe remote 8025 Universal transmitter can be associated with Burkert flowmeter 8020, 8030, SE30 + S077 or another flow sensor which emits a frequency signal (with pulse output signal). The remote 8025 transmitter can only be associated with Burkert flowmeter 8020, 8030, SE30 + S077 with sinus or pulse output signal in a “Low Power” version.
When connected to a flowmeter, the device makes it possible to switch a solenoid valve, activate an alarm or generate a flow rate proportional frequency, thanks to a digital output and, for some versions, by means of two relay outputs, fully configurable, and to establish a control loop thanks to a 4-20 mA current output.
1 - 12 of 16 Part Numbers
418 396
- Type - Remote Transmitter
- Mounting - Transmitter, Wall Mounted, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (3-Wires) + Pulse
- Relay - 2 Relays
- Electrical Connection - 3 Cable Glands
418 397
- Type - Remote Transmitter
- Mounting - Transmitter, Wall Mounted, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (2-Wires) + Pulse
- Relay - No Relay
- Electrical Connection - 3 Cable Glands
418 399
- Type - Remote Transmitter
- Mounting - Transmitter, Wall Mounted, 2 Totalizers
- Supply Voltage - 115/230 Vac
- Output - 4-20 mA (3-Wires) + Pulse
- Relay - 2 Relays
- Electrical Connection - 3 Cable Glands
418 400
- Type - Remote Transmitter
- Mounting - Transmitter, Wall Mounted, 2 Totalizers
- Supply Voltage - 115/230 Vac
- Output - 4-20 mA (2-Wires) + Pulse
- Relay - No Relay
- Electrical Connection - 3 Cable Glands
418 992
- Type - Remote Transmitter
- Mounting - Transmitter, Panel Mounted, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (2-Wires) + Pulse
- Relay - No Relay
- Electrical Connection - Terminal Strip
418 994
- Type - Remote Transmitter
- Mounting - Transmitter, Panel Mounted, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (3-Wires) + Pulse
- Relay - 2 Relays
- Electrical Connection - Terminal Strip
419 537
- Type - Remote Universal Transmitter
- Mounting - Universal Transmitter, Panel Mounted
- Supply Voltage - 12-36 Vdc
- Relay - 2 Relays
- Electrical Connection - Terminal Strip
419 538
- Type - Remote Universal Transmitter
- Mounting - Universal Transmitter, Panel Mounted
- Supply Voltage - 12-36 Vdc
- Relay - No Relay
- Electrical Connection - Terminal Strip
419 540
- Type - Remote Universal Transmitter
- Mounting - Universal Transmitter, Wall Mounted
- Supply Voltage - 12-36 Vdc
- Relay - 2 Relays
- Electrical Connection - 3 Cable Glands
419 541
- Type - Remote Universal Transmitter
- Mounting - Universal Transmitter, Wall Mounted
- Supply Voltage - 12-36 Vdc
- Relay - No Relay
- Electrical Connection - 3 Cable Glands
419 543
- Type - Remote Universal Transmitter
- Mounting - Universal Transmitter, Wall Mounted
- Supply Voltage - 115/230 Vac
- Relay - 2 Relays
- Electrical Connection - 3 Cable Glands
419 544
- Type - Remote Universal Transmitter
- Mounting - Universal Transmitter, Wall Mounted
- Supply Voltage - 115/230 Vac
- Relay - No Relay
- Electrical Connection - 3 Cable Glands
1 - 12 of 16 Part Numbers
Specifications
Accuracy
- Uncertainty of Measurement: ± 1 % of Range
Ambient Temperature Range
- Operation & Storage: -10° to 60° C (14° to 140° F)
- UL Recognized: 0° to 40° C (32° to 104° F)
Approvals & Certifications
- EN 61010-1
Approvals & Certifications
- UL (C,US) 61010-1
Cable Material
- Cable Clips (Panel-Mounted Version): Polyamide (PA)
Circuit Protection
- Short Circuit: Protected for Transistor Outputs
Consumption
- Current (Version with Relay): ≤ 45 mA at 36 Vdc - Remote Universal Transmitter (without Sensor)
- Current (Version with Relay): ≤ 50 mA at 115/230 Vac - Remote Universal Transmitter (without Sensor)
- Current (Version with Relay): ≤ 70 mA at 12 Vdc - Remote Universal Transmitter (without Sensor), Remote Transmitter (with Sensor)
- Current (Version without Relays): ≤ 25 mA at 12 Vdc - Remote Transmitter (with Sensor)
- Current (Version without Relays): ≤ 30 mA at 36 Vdc - Remote Universal Transmitter (without Sensor)
- Current (Version without Relays): ≤ 35 mA at 115/230 Vdc - Remote Universal Transmitter (without Sensor)
- Current (Version without Relays): ≤ 50 mA at 12 Vdc - Remote Universal Transmitter (without Sensor)
Cover Material
- Panel-Mounted Version: Polycarbonate (PC)
- Wall Mounted Version: ABS
Current
- Output: 22 mA - Remote Universal Transmitter
- Output: 4-20 mA - Remote Universal Transmitter, Remote Transmitter (3-Wire with Relays, 2-Wire without Relay)
- Wall Mounted Version (Fuse): 250 mA - Max.
Diameter
- External Cable Diameter (For the Cable Glands of the Wall Mounted Version): 4 to 8 mm
Display
- Large Digital Display with 8-Characters
Electrical Connectors
- 3 Cable Glands
- Panel-Mounted Version: Terminals
- Terminal Strip
- Wall Mounted Version: Terminals Via Gland M16 x 1.5
Electrical Contacts
- Normally Open
Electrical Protection
- Voltage Peak: Protected
Enclosure, Body Material
- Panel-Mounted Version: Polycarbonate (PC)
- Wall Mounted Version: ABS
Environmental Protection
- Panel-Mounted Version (Rear Side): IP20
- Wall Mounted Version, Panel-Mounted Version (Front Side): IP65
Frequency
- Transmitter Input & Output: 0.6 to 2.2 kHz - Remote Universal Transmitter
- Transmitter Input & Pulse Output: 2.5 to 400 Hz, 5-36 Vdc - Remote Transmitter
Gland Material
- Cable Glands (Wall Mounted Version): Polyamide (PA)
Humidity
- Maximum
Indication
- LED
Input
- Transmitter Input - Pulse: Open Collector NPN (with 470 ohms or 2.2 kiloohms Resistance) or PNP, TTL, CMOS (with 39 kiloohms Resistance) - Remote Universal Transmitter
- Transmitter Input - Sine-wave, Coil (with 39 kiloohms Resistance - with Min. Sensitivity of 50 mV Peak-to-Peak) - Remote Universal Transmitter
Loop Impedance
- 1,000 ohms at 30 Vdc, Max.
- 1,300 ohms at 36 Vdc, Max.
- 200 ohms at 12 Vdc, Max.
- 300 ohms at 15 Vdc, Max.
- 50 ohms at 12 Vdc, Max.
- 600 ohms at 24 Vdc, Max.
- 750 ohms at 24 Vdc, Max.
- 800 ohms with 115/230 Vac, Max.
- 900 ohms, Max.
Materials of Construction
- Front Panel Foil: Polyester
Mounting
- Panel-Mounted
- Wall Mounted
Output
- 4-20 mA - Remote Universal Transmitter (3-Wires), Remote Transmitter (2 or 3-Wires)
- Pulse (Transistor): Line Drop at 100 mA: 2.5 Vdc - Remote Transmitter
- Transistor: Line Drop at 100 mA: 2.7 Vdc - Remote Universal Transmitter
Power
- Relay (Cutting Power): 750 VA, Max.
- Wall Mounted Version: 6 VA
Power Supply
- 115/230 Vav at 50/60 Hz - Remote Transmitter (Wall Mounted Version), Remote Universal Transmitter
- 12-36 Vdc - Remote Universal Transmitter (2-Wire), Remote Transmitter (2 or 3-Wire)
- Panel-Mounted & Wall Mounted Version: 12-36 Vdc ± 10 % - Remote Transmitter
Relay Output
- 230 Vac / 3 A
- 40 Vdc / 3 A (Resistive Load)
- UL Recognized: 30 Vac
- UL Recognized: 42 V Peak, Max.
- UL Recognized: 60 Vdc, Max.
Response Time
- 10 to 90 %: 6 seconds - Remote Transmitter
Reverse Polarity Protection
- Yes
Screw Material
- Stainless Steel
Supply Voltage
- Transmitter Output (with a 115/230 Vac Powered Transmitter): 14.5 Vdc, 80 mA - Max.
- Transmitter Output (with a 115/230 Vac Powered Transmitter): 27 Vdc, 80 mA - Max.
- Transmitter Output (with a 12-36 Vdc [Regulated] & 115/230 Vac Powered Transmitter): 5 Vdc, 30 mA - Max.
- Transmitter Output (with a 12-36 Vdc Powered Transmitter): 0-23.5 Vdc, 80 mA - Max.
- Transmitter Output (with a 12-36 Vdc Powered Transmitter): 10.5-34.5 Vdc, 140 mA - Max.
- Transmitter Output: 10-34 Vdc, 1 mA - Max.
Switch Type
- Transistor: NPN or PNP
Tolerance
- ± 10 % at 36 Vdc, Max.
- 10 % at 12 Vdc, Max.
- -5 % at 12 Vdc, Max.
Voltage
- Transmitter Input: 36 Vdc, Max.