The remote 8025 Universal transmitter can be associated with Burkert flowmeter 8020, 8030, SE30 + S077 or another flow sensor which emits a frequency signal (with pulse output signal). The remote 8025 transmitter can only be associated with Burkert flowmeter 8020, 8030, SE30 + S077 with sinus or pulse output signal in a “Low Power” version. 

When connected to a flowmeter, the device makes it possible to switch a solenoid valve, activate an alarm or generate a flow rate proportional frequency, thanks to a digital output and, for some versions, by means of two relay outputs, fully configurable, and to establish a control loop thanks to a 4-20 mA current output.

1 - 12 of 16 Part Numbers
418 396
418 396
  • Type - Remote Transmitter
  • Mounting - Transmitter, Wall Mounted, 2 Totalizers
  • Supply Voltage - 12-36 Vdc
  • Output - 4-20 mA (3-Wires) + Pulse
  • Relay - 2 Relays
  • Electrical Connection - 3 Cable Glands
418 397
418 397
  • Type - Remote Transmitter
  • Mounting - Transmitter, Wall Mounted, 2 Totalizers
  • Supply Voltage - 12-36 Vdc
  • Output - 4-20 mA (2-Wires) + Pulse
  • Relay - No Relay
  • Electrical Connection - 3 Cable Glands
418 399
418 399
  • Type - Remote Transmitter
  • Mounting - Transmitter, Wall Mounted, 2 Totalizers
  • Supply Voltage - 115/230 Vac
  • Output - 4-20 mA (3-Wires) + Pulse
  • Relay - 2 Relays
  • Electrical Connection - 3 Cable Glands
418 400
418 400
  • Type - Remote Transmitter
  • Mounting - Transmitter, Wall Mounted, 2 Totalizers
  • Supply Voltage - 115/230 Vac
  • Output - 4-20 mA (2-Wires) + Pulse
  • Relay - No Relay
  • Electrical Connection - 3 Cable Glands
418 992
418 992
  • Type - Remote Transmitter
  • Mounting - Transmitter, Panel Mounted, 2 Totalizers
  • Supply Voltage - 12-36 Vdc
  • Output - 4-20 mA (2-Wires) + Pulse
  • Relay - No Relay
  • Electrical Connection - Terminal Strip
418 994
418 994
  • Type - Remote Transmitter
  • Mounting - Transmitter, Panel Mounted, 2 Totalizers
  • Supply Voltage - 12-36 Vdc
  • Output - 4-20 mA (3-Wires) + Pulse
  • Relay - 2 Relays
  • Electrical Connection - Terminal Strip
419 537
419 537
  • Type - Remote Universal Transmitter
  • Mounting - Universal Transmitter, Panel Mounted
  • Supply Voltage - 12-36 Vdc
  • Relay - 2 Relays
  • Electrical Connection - Terminal Strip
419 538
419 538
  • Type - Remote Universal Transmitter
  • Mounting - Universal Transmitter, Panel Mounted
  • Supply Voltage - 12-36 Vdc
  • Relay - No Relay
  • Electrical Connection - Terminal Strip
419 540
419 540
  • Type - Remote Universal Transmitter
  • Mounting - Universal Transmitter, Wall Mounted
  • Supply Voltage - 12-36 Vdc
  • Relay - 2 Relays
  • Electrical Connection - 3 Cable Glands
419 541
419 541
  • Type - Remote Universal Transmitter
  • Mounting - Universal Transmitter, Wall Mounted
  • Supply Voltage - 12-36 Vdc
  • Relay - No Relay
  • Electrical Connection - 3 Cable Glands
419 543
419 543
  • Type - Remote Universal Transmitter
  • Mounting - Universal Transmitter, Wall Mounted
  • Supply Voltage - 115/230 Vac
  • Relay - 2 Relays
  • Electrical Connection - 3 Cable Glands
419 544
419 544
  • Type - Remote Universal Transmitter
  • Mounting - Universal Transmitter, Wall Mounted
  • Supply Voltage - 115/230 Vac
  • Relay - No Relay
  • Electrical Connection - 3 Cable Glands
1 - 12 of 16 Part Numbers

Specifications

Accuracy

  • Uncertainty of Measurement: ± 1 % of Range

Ambient Temperature Range

  • Operation & Storage: -10° to 60° C (14° to 140° F)
  • UL Recognized: 0° to 40° C (32° to 104° F)

Approvals & Certifications

  • EN 61010-1

Approvals & Certifications

  • UL (C,US) 61010-1

Cable Material

  • Cable Clips (Panel-Mounted Version): Polyamide (PA)

Circuit Protection

  • Short Circuit: Protected for Transistor Outputs

Consumption

  • Current (Version with Relay): ≤ 45 mA at 36 Vdc - Remote Universal Transmitter (without Sensor)
  • Current (Version with Relay): ≤ 50 mA at 115/230 Vac - Remote Universal Transmitter (without Sensor)
  • Current (Version with Relay): ≤ 70 mA at 12 Vdc - Remote Universal Transmitter (without Sensor), Remote Transmitter (with Sensor)
  • Current (Version without Relays): ≤ 25 mA at 12 Vdc - Remote Transmitter (with Sensor)
  • Current (Version without Relays): ≤ 30 mA at 36 Vdc - Remote Universal Transmitter (without Sensor)
  • Current (Version without Relays): ≤ 35 mA at 115/230 Vdc - Remote Universal Transmitter (without Sensor)
  • Current (Version without Relays): ≤ 50 mA at 12 Vdc - Remote Universal Transmitter (without Sensor)

Cover Material

  • Panel-Mounted Version: Polycarbonate (PC)
  • Wall Mounted Version: ABS

Current

  • Output: 22 mA - Remote Universal Transmitter
  • Output: 4-20 mA - Remote Universal Transmitter, Remote Transmitter (3-Wire with Relays, 2-Wire without Relay)
  • Wall Mounted Version (Fuse): 250 mA - Max.

Diameter

  • External Cable Diameter (For the Cable Glands of the Wall Mounted Version): 4 to 8 mm

Display

  • Large Digital Display with 8-Characters

Electrical Connectors

  • 3 Cable Glands
  • Panel-Mounted Version: Terminals
  • Terminal Strip
  • Wall Mounted Version: Terminals Via Gland M16 x 1.5

Electrical Contacts

  • Normally Open

Electrical Protection

  • Voltage Peak: Protected

Enclosure, Body Material

  • Panel-Mounted Version: Polycarbonate (PC)
  • Wall Mounted Version: ABS

Environmental Protection

  • Panel-Mounted Version (Rear Side): IP20
  • Wall Mounted Version, Panel-Mounted Version (Front Side): IP65

Frequency

  • Transmitter Input & Output: 0.6 to 2.2 kHz - Remote Universal Transmitter
  • Transmitter Input & Pulse Output: 2.5 to 400 Hz, 5-36 Vdc - Remote Transmitter

Gland Material

  • Cable Glands (Wall Mounted Version): Polyamide (PA)

Humidity

  • Maximum

Indication

  • LED

Input

  • Transmitter Input - Pulse: Open Collector NPN (with 470 ohms or 2.2 kiloohms Resistance) or PNP, TTL, CMOS (with 39 kiloohms Resistance) - Remote Universal Transmitter
  • Transmitter Input - Sine-wave, Coil (with 39 kiloohms Resistance - with Min. Sensitivity of 50 mV Peak-to-Peak) - Remote Universal Transmitter

Loop Impedance

  • 1,000 ohms at 30 Vdc, Max.
  • 1,300 ohms at 36 Vdc, Max.
  • 200 ohms at 12 Vdc, Max.
  • 300 ohms at 15 Vdc, Max.
  • 50 ohms at 12 Vdc, Max.
  • 600 ohms at 24 Vdc, Max.
  • 750 ohms at 24 Vdc, Max.
  • 800 ohms with 115/230 Vac, Max.
  • 900 ohms, Max.

Materials of Construction

  • Front Panel Foil: Polyester

Mounting

  • Panel-Mounted
  • Wall Mounted

Output

  • 4-20 mA - Remote Universal Transmitter (3-Wires), Remote Transmitter (2 or 3-Wires)
  • Pulse (Transistor): Line Drop at 100 mA: 2.5 Vdc - Remote Transmitter
  • Transistor: Line Drop at 100 mA: 2.7 Vdc - Remote Universal Transmitter

Power

  • Relay (Cutting Power): 750 VA, Max.
  • Wall Mounted Version: 6 VA

Power Supply

  • 115/230 Vav at 50/60 Hz - Remote Transmitter (Wall Mounted Version), Remote Universal Transmitter
  • 12-36 Vdc - Remote Universal Transmitter (2-Wire), Remote Transmitter (2 or 3-Wire)
  • Panel-Mounted & Wall Mounted Version: 12-36 Vdc ± 10 % - Remote Transmitter

Relay Output

  • 230 Vac / 3 A
  • 40 Vdc / 3 A (Resistive Load)
  • UL Recognized: 30 Vac
  • UL Recognized: 42 V Peak, Max.
  • UL Recognized: 60 Vdc, Max.

Response Time

  • 10 to 90 %: 6 seconds - Remote Transmitter

Reverse Polarity Protection

  • Yes

Screw Material

  • Stainless Steel

Supply Voltage

  • Transmitter Output (with a 115/230 Vac Powered Transmitter): 14.5 Vdc, 80 mA - Max.
  • Transmitter Output (with a 115/230 Vac Powered Transmitter): 27 Vdc, 80 mA - Max.
  • Transmitter Output (with a 12-36 Vdc [Regulated] & 115/230 Vac Powered Transmitter): 5 Vdc, 30 mA - Max.
  • Transmitter Output (with a 12-36 Vdc Powered Transmitter): 0-23.5 Vdc, 80 mA - Max.
  • Transmitter Output (with a 12-36 Vdc Powered Transmitter): 10.5-34.5 Vdc, 140 mA - Max.
  • Transmitter Output: 10-34 Vdc, 1 mA - Max.

Switch Type

  • Transistor: NPN or PNP

Tolerance

  • ± 10 % at 36 Vdc, Max.
  • 10 % at 12 Vdc, Max.
  • -5 % at 12 Vdc, Max.

Voltage

  • Transmitter Input: 36 Vdc, Max.