Yodify Product Library
Instantly add the Reversing Starter Max. 4 kW / 400 V Series 8510 and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
Reversing Starter Max. 4 kW / 400 V Series 8510
Brand: R. STAHL AGThe R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3.
This module is available in outputs up to 4 kW and is designed for voltages up to 400 V.
It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
Features- Type-tested standard components
- For outputs up to 4 kW/400 W
- Corrosion-resistant enclosure material
- Combined device results in minimized wiring expenditure
1 - 10 of 10 Part Numbers
145869
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-..0
- Title Product Variant Technical Data - 8510/132-08-134-..0 contactor-type rever
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217757
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 24 V AC 50/60 Hz
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-010
- Title Product Variant Technical Data - 8510/132-08-134-010 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217758
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 42 V AC 50/60 Hz
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-020
- Title Product Variant Technical Data - 8510/132-08-134-020 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217759
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 110 V AC 50/60 Hz
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-030
- Title Product Variant Technical Data - 8510/132-08-134-030 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217760
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 220 / 230 V AC 50/60 Hz
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-040
- Title Product Variant Technical Data - 8510/132-08-134-040 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217761
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 500 V AC 50/60 Hz
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-060
- Title Product Variant Technical Data - 8510/132-08-134-060 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217762
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 230 / 240 V AC 50/60 Hz
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-070
- Title Product Variant Technical Data - 8510/132-08-134-070 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217763
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 400 / 415 V AC 50/60 Hz
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-080
- Title Product Variant Technical Data - 8510/132-08-134-080 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217764
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 24 V DC
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-210
- Title Product Variant Technical Data - 8510/132-08-134-210 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
217765
Type-tested standard components
For outputs up to 4 kW/400 W
Corrosion-resistant enclosure material
Combined device results in minimised wiring expenditure
Ambient Conditions
- Ambient temperature - -20 °C ... +40 °C
- Ambient temperature max. - +40 °C
- Ambient temperature min. - -20 °C
Electrical Data
- Auxiliary contacts - 4 (4 NO)
- Main contacts - 3-pole (3 NOs)
- Rated actuating voltage - 48 V DC
- Switching capacity - 4 kW / 400 V
Explosion Protection
- Application range (zones) - 1, 2
- ATEX firedamp certificate - DMT 00 ATEX E 073 U
- ATEX gas certificate - DMT 00 ATEX E 073 U
- Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
- Firedamp protection ATEX - I M2 Ex de I
- Firedamp protection IECEx - Ex de I
- Gas explosion protection ATEX - II 2 G Ex de IIC
- Gas explosion protection IECEx - Ex de IIC
- IECEx firedamp certificate - IECEx BVS 07.0029U
- IECEX gas certificate - IECEx BVS 07.0029U
General
- Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 4 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
- Highlights - Type-tested standard components For outputs up to 4 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
- Product Description - Reversing starter combination
- Product Type - 8510/132-08-134-230
- Title Product Variant Technical Data - 8510/132-08-134-230 Reversing contactor
- WebCode - 8510H
Mechanical Data
- Connection terminals finely-stranded max. - 6.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
- Connection terminals of auxiliary contact min. - 0.75 mm²
- Connection terminals of auxiliary contact solid max. - 2.50 mm²
- Connection terminals solid max. - 10.00 mm²
- Degree of protection (IP) - IP20
- Depth - 168.000 mm
- Enclosure material - Epoxy resin
- Height - 130.000 mm
- Type of connection cable - Finely stranded, solid
- Weight - 2.600 kg
- Width - 115.000 mm
1 - 10 of 10 Part Numbers