7600 Flow-Through pH Sensor

Brand: ABB Group

The pH / redox (ORP) sensing system 7600 is the result of over fifty years experience of continuous on-line pH measurement. 

Flow-through and immersion versions are available. 

Both types can be supplied in glass-coupled polypropylene. 

A stainless steel version is available as a flow system that caters predominantly for low-conductivity and high-temperature applications.
Features
  • Designed specifically for power and potable water industry applications
    • where pH and REDOX (ORP) measurements are critical
  • Optical stainless steel flowcell
    • essential for high purity water applications
  • Economical option for applications where the conductivity is above 20 μS/cm
    • utilizing a polypropylene flowcell
  • Flowing reference junction option
    • provides a very stable junction potential in high purity water or high suspended solids applications
  • Replaceable reference junction
    • simple to replace for reliable, low-cost maintenance
  • Separate detachable-lead electrodes
    • provides versatility and low-cost electrode replacement
  • Low resistance electrode option
    • for fast response in low temperature applications

1 - 12 of 90 Part Numbers
7651/000
7651/000
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - No Sensor
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - No Cable
7651/001
7651/001
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - 1720-000 All Purpose Glass Electrode, 1730-000 Standard Reference Electrode, 1750-000 Pt100 Temperature Compensator. Recommended for General-Purpose Applications
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - No Cable
7651/002
7651/002
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - 1722-000 Low Resistance Glass Electrode, 1730-000 Standard Reference Electrode, 1750-000 Pt100 Temperature Compensator. Recommended for Low Temperature Applications < 10° C (50° F)
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - No Cable
7651/010
7651/010
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - No Sensor
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 3 m (10 ft)
7651/011
7651/011
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - 1720-000 All Purpose Glass Electrode, 1730-000 Standard Reference Electrode, 1750-000 Pt100 Temperature Compensator. Recommended for General-Purpose Applications
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 3 m (10 ft)
7651/012
7651/012
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - 1722-000 Low Resistance Glass Electrode, 1730-000 Standard Reference Electrode, 1750-000 Pt100 Temperature Compensator. Recommended for Low Temperature Applications < 10° C (50° F)
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 3 m (10 ft)
7651/020
7651/020
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - No Sensor
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 5 m (16 ft)
7651/021
7651/021
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - 1720-000 All Purpose Glass Electrode, 1730-000 Standard Reference Electrode, 1750-000 Pt100 Temperature Compensator. Recommended for General-Purpose Applications
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 5 m (16 ft)
7651/022
7651/022
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - 1722-000 Low Resistance Glass Electrode, 1730-000 Standard Reference Electrode, 1750-000 Pt100 Temperature Compensator. Recommended for Low Temperature Applications < 10° C (50° F)
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 5 m (16 ft)
7651/030
7651/030
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - No Sensor
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 10 m (32 ft)
7651/031
7651/031
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - 1720-000 All Purpose Glass Electrode, 1730-000 Standard Reference Electrode, 1750-000 Pt100 Temperature Compensator. Recommended for General-Purpose Applications
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 10 m (32 ft)
7651/032
7651/032
  • System Type & Material - Polypropylene Systems
  • Connection Cable Length & Type - With Automatic Temperature Compensation for pH
  • Sensor Type - 1722-000 Low Resistance Glass Electrode, 1730-000 Standard Reference Electrode, 1750-000 Pt100 Temperature Compensator. Recommended for Low Temperature Applications < 10° C (50° F)
  • Model - Flow System with 1/2 In. & 1 In. Process Connections
  • Cable Length - 10 m (32 ft)
1 - 12 of 90 Part Numbers

Specifications

Brand

Enclosure / Body Material

  • Body: Glass-Reinforced Polypropylene

Material of Construction

  • Flowcell:  Stainless Steel

pH Range

  • 0 t 14

Operating Temperature

  • -5° to 100° C (23° to 212 F)

Maximum Operating Pressure

  • 10.6 bar (150 lbf/in²) at 25° C (77° F)

Process Conenction

  • 1” Female BSPP with 1/2” Female BSPT Adaptors
  • 3/8” Female NPT

Mounting

  • Wall Mounting
  • Panel Mounting