Yodify Product Library
Instantly add the Sockets 16 A Series 8570/21 and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Sockets 16 A Series 8570/21
Brand: R. STAHL AGR. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A.
The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position.
Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily.
The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
Features- Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
- Optional Ex e or Ex i auxiliary contacts for control and signaling purposes, further optional equipment
- With AC-3 motor switching capacity according to IEC/EN 60947-3
1 - 9 of 9 Part Numbers
150608
Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Entries - 2 x NPS 3/4"
- Plate with threaded holes - 2 x NPSM 3/4"
- Screw connections - Can be ordered as accessories
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 480.00 V
- Rated operational voltage AC - 0.00 - 480.00 V
- Rated operational voltage AC 2 - 0.00 - 277.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8570/21-507
- Title Product Variant Technical Data - 8570/21-507 WA 480Y/277 V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - red
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 6.00 mm²
- Connection terminals solid max. - 6,00 mm2
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide
- Height - 181.000 mm
- Length - 248.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Type of connection cable - Finely stranded, solid
- Weight - 0.500 kg
- Width - 115.000 mm
150612
Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Entries - 2 x NPS 3/4"
- Plate with threaded holes - 2 x NPSM 3/4"
- Screw connections - Can be ordered as accessories
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 20.000 A
- Rated operational current - 0.000 - 20.000 A
- Rated operational voltage AC - 0.00 - 208.00 V
- Rated operational voltage AC - 208.00 V
- Rated operational voltage AC 2 - 0.00 - 120.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8570/21-509
- Title Product Variant Technical Data - 8570/21-509 WA 208Y/120 V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 9
- Colour code - blue
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 6,00 mm2
- Connection terminals solid max. - 6.00 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide
- Height - 181.000 mm
- Length - 248.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Type of connection cable - Finely stranded, solid
- Weight - 0.500 kg
- Width - 115.000 mm
150615
Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Entries - 2 x NPS 3/4"
- Plate with threaded holes - 2 x NPSM 3/4"
- Screw connections - Can be ordered as accessories
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - Yes
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 0.00 - 600.00 V
- Rated operational voltage AC - 600.00 V
- Rated operational voltage AC 2 - 0.00 - 347.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8570/21-505
- Title Product Variant Technical Data - 8570/21-505 WA 600Y/347 V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 5
- Colour code - black
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 6.00 mm²
- Connection terminals solid max. - 6,00 mm2
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 5 P (3 P + N + PE)
- Enclosure material - Polyamide
- Height - 181.000 mm
- Length - 248.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Type of connection cable - Finely stranded, solid
- Weight - 0.500 kg
- Width - 115.000 mm
150619
Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Entries - 2 x NPS 3/4"
- Plate with threaded holes - 2 x NPSM 3/4"
- Screw connections - Can be ordered as accessories
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 0.00 - 480.00 V
- Rated operational voltage AC - 480.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8570/21-407
- Title Product Variant Technical Data - 8570/21-407 WA 480V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - red
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 6,00 mm2
- Connection terminals solid max. - 6.00 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide
- Height - 181.000 mm
- Length - 248.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Type of connection cable - Finely stranded, solid
- Weight - 0.500 kg
- Width - 115.000 mm
150623
Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Entries - 2 x NPS 3/4"
- Plate with threaded holes - 2 x NPSM 3/4"
- Screw connections - Can be ordered as accessories
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 0.00 - 250.00 V
- Rated operational voltage AC - 250.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8570/21-409
- Title Product Variant Technical Data - 8570/21-409 WA 250V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 9
- Colour code - blue
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 6.00 mm²
- Connection terminals solid max. - 6,00 mm2
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide
- Height - 181.000 mm
- Length - 248.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Type of connection cable - Finely stranded, solid
- Weight - 0.500 kg
- Width - 115.000 mm
150626
Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Entries - 2 x NPS 3/4"
- Plate with threaded holes - 2 x NPSM 3/4"
- Screw connections - Can be ordered as accessories
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 600.00 V
- Rated operational voltage AC - 0.00 - 600.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8570/21-405
- Title Product Variant Technical Data - 8570/21-405 WA 600V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 5
- Colour code - black
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 6.00 mm²
- Connection terminals solid max. - 6,00 mm2
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 4 P (3 P + PE)
- Enclosure material - Polyamide
- Height - 181.000 mm
- Length - 248.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Type of connection cable - Finely stranded, solid
- Weight - 0.500 kg
- Width - 115.000 mm
150634
Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Entries - 1 x NPT 3/4"
- Plate with threaded holes - 1 x NPSM 3/4"
- Screw connections - Can be ordered as accessories
- Stopping plug - 1 x M25
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 20.000 A
- Rated operational current - 0.000 - 20.000 A
- Rated operational voltage AC - 480.00 V
- Rated operational voltage AC - 0.00 - 480.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8570/21-307
- Title Product Variant Technical Data - 8570/21-307 WA 480V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 7
- Colour code - red
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 6,00 mm2
- Connection terminals solid max. - 6.00 mm²
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 3 P (2 P + PE)
- Enclosure material - Polyamide
- Height - 168.000 mm
- Length - 232.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Type of connection cable - Finely stranded, solid
- Weight - 0.500 kg
- Width - 105.000 mm
150638
Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide
Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment
With AC-3 motor switching capacity according to IEC/EN 60947-3
Ambient Conditions
- Ambient temperature - -30 °C ... +55 °C
- Ambient temperature °F - -58 - 131 °F
- Ambient temperature max. - +55 °C
- Ambient temperature min. - -30 °C
Components
- Entries - 1 x NPT 3/4"
- Plate with threaded holes - 1 x NPSM 3/4"
- Screw connections - Can be ordered as accessories
- Stopping plug - 1 x M25
- Stopping plug material - Polyamide, black
Electrical Data
- Auxiliary contacts available - No
- Frequency range - 50 - 60 Hz
- N-pole present - No
- Optional auxiliary contacts - Yes
- PE-pole present - Yes
- Rated operational current - 0.000 - 20.000 A
- Rated operational current - 20.000 A
- Rated operational voltage AC - 0.00 - 125.00 V
- Rated operational voltage AC - 125.00 V
- Type of voltage - Low voltage
Explosion Protection
- Ambient temperature °C - -30 - 55 °C
- Application range (zones) - 1, 2, 21, 22
- ATEX dust certificate - PTB 03 ATEX 1227
- ATEX gas certificate - PTB 03 ATEX 1227
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), IECEx (PTB), USA (FM)
- Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
- Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
- Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
- Gas explosion protection IECEx - Ex db eb IIC T6 Gb
- IECEX dust certificate - IECEx PTB 05.0023
- IECEX gas certificate - IECEx PTB 05.0023
- Languages of the documentation - English
- NEC 500 zones - Class I, Div. 2,
- NEC 505 gas Ex-type - AEx
- NEC 505 zones - Class I, Zone 1 & 2,
General
- Functional Description - R. STAHL Series 8570/21 SolConeX sockets for Zone 1/21 in a 3-,4- and 5-pole version have full AC-3 switching capacity up to 16 A. The high degree of protection IP66 guarantees the highest level of protection against the penetration of dust and/or water in any application position. Self-cleaning lamellar contacts provide optimum contact and the plugs can be inserted and removed in the zero position quickly and easily. The load disconnect switch, with mechanical locking device and a handle that can be locked in the 0 or I position, is an additional safety feature.
- Highlights - Degree of protection IP66, extreme temperature range of –50 to +55 °C, usable worldwide Optional Ex e or Ex i auxiliary contacts for control and signalling purposes, further optional equipment With AC-3 motor switching capacity according to IEC/EN 60947-3
- Product Description - Switch socket
- Product Type - 8570/21-304
- Title Product Variant Technical Data - 8570/21-304 WA 125V, 50/60Hz
Mechanical Data
- Coding (clock hour position) - 4
- Colour code - yellow
- Connection terminals finely-stranded max. - 4.00 mm²
- Connection terminals finely-stranded max. - 4,00 mm2
- Connection terminals min. - 1.50 mm²
- Connection terminals solid max. - 6.00 mm²
- Connection terminals solid max. - 6,00 mm2
- Connection terminals USA max. - 12 AWG
- Connection terminals USA min. - 16 AWG
- Degree of protection (IP) - IP66
- Detailed number of poles - 3 P (2 P + PE)
- Enclosure material - Polyamide
- Height - 168.000 mm
- Length - 232.000 mm
- Lockable in - in 0- and I-position
- Series - SolConeX
- Type of connection cable - Finely stranded, solid
- Weight - 0.500 kg
- Width - 105.000 mm
1 - 9 of 9 Part Numbers