Yodify Product Library
Instantly add the 8035-Digital Flow Transmitter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
8035-Digital Flow Transmitter
Brand: Burkert Fluid Control SystemsThe flow transmitter is specially designed for use in neutral, slightly aggressive, solid free liquids. The transmitter is made up of a compact fitting with paddle wheel (S030) and an electronic module (SE35) quickly and easily connected together by a Quarter-Turn.
The Burkert designed fitting system ensures simple installation of the sensors into all pipes from DN06 to DN65.
The device is available in different models:
- Flow transmitter with standard output signal
- Battery powered
- Compact version for DN06 to DN65
- Displays both flow rate and volume (with two totalizers)
- Automatic calibration: Teach-In
- Simulation: All output signals provided without the need for real flow
1 - 8 of 8 Part Numbers
423 921
- Model - Indicator, 2 Totalizers
- Supply Voltage - 4 x 1.5 Vdc AA Batteries
- Output - No Output
- Relay - No Relays
- Agreement - No Agreement
- Electrical Connection - Without Electrical Connection
423 922
- Model - Standard Output Signal Transmitter, 2 Totalizers
- Supply Voltage - 115/230 Vac
- Output - 4-20 mA (2-Wires) + Pulse
- Relay - No Relays
- Agreement - No Agreement
- Electrical Connection - 2 Cable Glands
423 924
- Model - Standard Output Signal Transmitter, 2 Totalizers
- Supply Voltage - 115/230 Vac
- Output - 4-20 mA (3-Wires) + Pulse
- Relay - 2 Relays
- Agreement - No Agreement
- Electrical Connection - 2 Cable Glands
444 005
- Model - Standard Output Signal Transmitter, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (2-Wires) + Pulse
- Relay - No Relays
- Agreement - No Agreement
- Electrical Connection - EN 175301-803
444 006
- Model - Standard Output Signal Transmitter, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (2-Wires) + Pulse
- Relay - No Relays
- Agreement - No Agreement
- Electrical Connection - 2 Cable Glands
444 007
- Model - Standard Output Signal Transmitter, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (3-Wires) + Pulse
- Relay - 2 Relays
- Agreement - No Agreement
- Electrical Connection - 2 Cable Glands
553 432
- Model - Standard Output Signal Transmitter, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (2-Wires) + Pulse
- Relay - No Relays
- Agreement - UL (C, US) Recognized
- Electrical Connection - 2 Cable Glands
553 433
- Model - Standard Output Signal Transmitter, 2 Totalizers
- Supply Voltage - 12-36 Vdc
- Output - 4-20 mA (3-Wires) + Pulse
- Relay - 2 Relays
- Agreement - UL (C, US) Recognized
- Electrical Connection - 2 Cable Glands
1 - 8 of 8 Part Numbers
Specifications
Accuracy
- 4-20 mA Output Uncertainty: ± 1 %
Ambient Temperature Range
- Operation & Storage: 0° to 50° C (32° to 122° F) (115/230 Vac Version)
- Operation & Storage: 0° to 55° C (32° to 131° F) (Batteries Version)
- Operation & Storage: 0° to 60° C (32° to 140° F) (12-36 Vdc)
- UL Recognized: 0° to 40° C (32° to 104° F)
Approvals & Certifications
- Safety: EN 61010-1
- CE
- EMC: EN 61000-6-2, EN 61000-6-3
- PED 2006/95/CE
- UL (C,US): UL 61010-1 + CAN/CSA C22.2 No. 61010-1
Bearing Material
- Ceramics
Consumption
- Current (Transmitter with Relays): ≤ 70 mA at 12 Vdc
- Current (Transmitter without Relay): ≤ 25 mA at 12 Vdc
Cover Material
- Polycarbonate (PC)
Current
- Fuse 125 mA - Max.
Diameter
- Pipe: 1/4 to 2-1/2” (DN06 to DN 65)
Display
- 15 x 60 mm, 8-Digit LCD, Alphanumeric, 15-Segments, 9 mm High
Electrical Connectors
- 50 metres, Max.
- Battery Version: Cable Glands M20 x 1.5
- Battery Version: Cable Plug EN 175301-803
- Shielded Cable with 1.5 mm², Max.
Enclosure, Body Material
- Polycarbonate (PC)
Environmental Protection
- IP65
Gland Material
- Polyamide (PA)
Humidity
- ≤ 80 % Relative Humidity, Non-Condensing
- UL Recognized: Max.
Indication
- LED
Linearity
- ± 0.5 % of Full Scale
Loop Impedance
- 50 ohms at 12 Vdc, Max.
- 600 ohms at 24 Vdc, Max.
- 800 ohms with a 115/230 Vac, Max.
- 900 ohms at 30 Vdc, Max.
Materials of Construction
- Front Panel Foil: Polyester
- Lid: Polycarbonate (PC)
Measuring Error
- Measurement Deviation (Standard K-factor): ± 2.5 % of Reading
- Measurement Deviation (Teach-In): ± 1 % of Reading
Measuring Range
- 0.3 to 10 m/sec
Nut & Bolt Material
- Nut: Polycarbonate (PC)
Output
- Pulse: 2.5 Vdc at 100 mA
- Pulse: 5-36 Vdc
- Standard Signal Version (3-Wire with Relays, 2-Wire without Relay): 4-20 mA
Pipe Connection
- DN 15 Pipe
- DN 20 Pipe
- DN 25 Pipe
- DN 32 Pipe
- DN 40 Pipe
- DN 50 Pipe
- DN 65 Pipe
Plug Material
- Cable Plug: Polyamide (PA)
Power
- 3 VA
Power Supply
- Battery Indicator/Totalizer Version: 4 x 1.5 Vdc Non-Rechargeable Alkaline AA Batteries
- Standard Signal Version: 115/230 Vac at 50/60 Hz
- Standard Signal Version: 12-36 Vdc ± 10 %
Pressure Range
- bar: 0 to 16
- kPa: 0 to 1,600
- psi: 0 to 232.16
Process Temperature
- PP: 0° to 80° C (32° to 176° F)
- PVC: 0° to 50° C (32° to 122° F)
- PVDF, Brass or Stainless Steel: -15° to 100° C (5° to 212° F)
Relay Output
- 2 Relays
- 230 Vac / 3 A
- Resistive Load: 40 Vdc / 3 A
- UL Recognized: 30 Vac
- UL Recognized: 42 V Peam, Max.
- UL Recognized: 60 Vdc, Max.
Repeatability
- ± 0.4 % of Reading
Reverse Polarity Protection
- Yes
Screw Material
- Stainless Steel
Seat / Seal Material
- Seal: EPDM
- Seal: FKM
Shock
- EN 60068-2-27
Supply Voltage
- 27 Vdc Regulated
Tri-Clamp Connection
- DN 15 Tri-Clamp
- DN 20 Tri-Clamp
- DN 25 Tri-Clamp
- DN 32 Tri-Clamp
- DN 40 Tri-Clamp
- DN 50 Tri-Clamp
- DN 65 Tri-Clamp
Vibration
- EN 60068-2-6
Viscosity
- 300 cSt, Max.
Welded Connection
- DN 15 Weld End
- DN 20 Weld End
- DN 25 Weld End
- DN 32 Weld End
- DN 40 Weld End
- DN 50 Weld End
- DN 65 Weld End
Wetted Materials
- Axis: Ceramics
- Fitting, Sensor Armature, Paddle-wheel: PVDF
- Fitting, Sensor Armature: 316L Stainless Steel, 1.4404
- Fitting, Sensor Armature: Brass
- Fitting, Sensor Armature: Polypropylene (PP)
- Fitting, Sensor Armature: PVC