Brand: PR Electronics

  • PROFIBUS PA ver. 3.0
  • FOUNDATION Fieldbus ver. ITK 4.6
  • Automatic switch between protocols
  • Basic or LAS capability with F.F.
  • 1- or 2-channel version
Features
  • Bus transmitter with both PROFIBUS PA and FOUNDATION Fieldbus communication. A unique switch function ensures automatic shift between the two protocols.
  • Set-up for PROFIBUS PA can be done via Siemens Simatic® PDM®, ABB Melody / Harmony and Metso DNA software and for FOUNDATION Fieldbus via Emerson DeltaV, Yokogawa CS 1000 / CS 3000, ABB Melody / Harmony and Honeywell Experion software.
  • Built-in simulation mode function.
  • Polarity-independent bus connection.
  • 24 bit A/D converter ensures high resolution.
  • PROFIBUS PA function blocks: 2 analog.
  • FOUNDATION Fieldbus function blocks: 2 analog and 1 PID.
  • FOUNDATION Fieldbus capability: Basic or LAS.

1 - 2 of 2 Part Numbers
6350A2A
6350A2A
  • Galvanic Isolation - 1500 Vac
  • Channels - Single
6350A2B
6350A2B
  • Galvanic Isolation - 1500 Vac
  • Channels - Double
1 - 2 of 2 Part Numbers

Specifications

Accuracy

  • ± 0.05 %

Approvals & Certifications

  • ATEX 2014/34/EU KEMA 03-ATEX-1013 X
  • CSA 1418937
  • EAC TR CU 020/2011
  • EMC 2014/30/EU
  • FM 3015609
  • IECEx dEK 14.0071X

Calibration

  • 20° to 28° C (68° to 82° F)

Environmental Protection

  • IP20

Humidity

  • < 95 % Relative Humidity, Non-Condensing

Load

  • ≤ (Vsupply-8) / 0.023 ohms

Output

  • FOUNDATION Fieldbus & PROFIBUS PA

Response Time

  • 1 to 60 seconds Programmable

RTD Type

  • Cu10 to 1000
  • Linch R
  • Ni25 to 1000
  • Potentiometer
  • Pt25 to 1000

Supply Voltage

  • 9.0-32 Vdc

Temperature Range

  • -40° to 85° C (-40° to 185° F)

  • Linearized temperature measurement with RTD or TC sensor.
  • Difference, average or redundancy temperature measurement with RTD or TC sensor.
  • Converts analog mA signals into digital values on the bus communication.
  • Linear resistance, potentiometer and bipolar mV measurement.