IFC 050 Signal Converter for Electromagnetic Flowmeter
Brand: KrohneThe electromagnetic signal converter IFC 050 is a perfect choice for measuring volumetric flow in various kinds of applications in the water industry but also in the food and beverage business.
The signal converter can be combined with the flow sensors OPTIFLUX 1000, 2000, 4000, 6000 and the WATERFLUX 3000.
The output represents measured values for flow, mass and conductivity.
Features- An active pulse output for a simple system, like driving an electro-mechanical counter
- RS485 Modbus communication with a data processing system
- Extra insulation of the electronic device and housing for high performance in areas with extreme humidity and chances for flooding
- Cost-effective flow measurement for a wide range of process conditions and still a very acceptable degree of accuracy
Specifications
Brand
Accuracy
- Option: ± 0.25 % of the Measured Value ± 1.5 mm/sec, Max.
- Standard: ± 0.5 % of Measured Value ± 1 mm/sec, Max.
Applications
- Agriculture
- Air Conditioning Systems
- CIP- Systems
- Food & Beverage
- Heating Systems
- Irrigation Systems
- Steel Mills
- Ventilation Systems
- Water & Wastewater
- Water Distribution Network, Abstraction
Approvals & Certifications
- IEC 60068-2-3, IEC 61298-3, IEC 68-2-64
Approvals & Certifications
- CE - EU Directives
- NAMUR - NE 21, NE 43, NE 53
Cable Entry
- 1/2” PF
- Option: 1/2” NPT
- Standard: M20 x 1.5 (8 to 12 mm)
Cable Length
- Signal: 1,950 feet (600 metres) Depending on Electrical Conductivity & Flow Sensor
Cable Type
- Double-Shielded Cable - Transmission between the Flow Sensor & Signal Converter
Communication
- Baud Rate: 1,200, 2,400, 3,600, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bit/sec
- HART
- Master/Slave
- Modbus RTU
- RS-485
Conductivity
- Electrical Conductivity - Water: ≥ 20 µS/cm
- Electrical Conductivity: ≥ 5 µS/cm (All Media Except for Water)
Consumption
- Power: 15 VA
- Power: 5.6 W
Control Functions Characteristics
- Status & Control: ON/OFF
Diagnostics
- Empty Pipe Detection
- Measuring Device
- Stabilization
Display
- 128 x 64 Pixels
- 2.32” x 1.22” (59 x 31 mm) - Ambient Temperature Below -25° C / -13° F May Affect the Readability of the Display
- LCD Display, Backlit White
Enclosure Finish
- Polyester Topcoat
Enclosure, Body Material
- Aluminum
Environmental Protection
- IP66
- IP67
- NEMA 4
- NEMA 4X
Flow Rate
- 0.005 to 48,858 m³/hour
- 0.3 to 12 m/sec
Frequency
- Pulse Rate / Frequency: 0.01 to 10,000 Hz
Function
- Step - the Time Constant Corresponds to the Elapsed Time Until 67 % of the End Value Has Been Reached
Hysteresis
- 0.1%
Load Resistance
- Test Point: ≥ 250 ohms at HART
Media
- Conductive Fluids
- Liquids
Operating Pressure
- psi: 0 to 72.52 (kPa: 0 to 500, bar: 0 to 5)
Output
- ± 10 µA, ± 100 ppm/°C (Typically: ± 30 ppm/°C)
- With & without HART: 10-21.5 mA, Q=100 %
- With HART: 4-20 mA, Q=0 %
- Without HART: 0-20 mA, Q=0 %
Power Supply
- 100-230 Vac, 50/60 Hz (-15 % / +10 %) Tolerance
- 24 Vdc (± 30 %) Tolerance
- 240 Vac - (5 % is Included in the Tolerance Range)
Principle of Operation
- Faraday's Law of Induction
Repeatability
- ± 0.1 %
Storage Temperature
- -40° to 70° C (-40° to 158° F)
Wiring
- Insulated Wire: 2 x 0.5 mm² Cu / AWG 20