GeniSys® 7580 240V Oil Burner Control

Brand: R.W. Beckett Corporation

The Beckett GeniSys® 7580 Oil Burner Control is a 240 VAC primary safety control for Commercial / Industrial pressure washer and other industrial applications.

The GeniSys® 7580 is used with the GeniSys® CAD Cell Flame Detector Kit 7006U to control the oil burner’s motor, igniter, and optional solenoid valve.

The control operates the burner with interrupted ignition with a 15 second lockout time.

With the GeniSys® Contractor Tool 52082, the control can be programmed with pre-purge and post-purge timings. For diagnostics, the GeniSys® 7580 stores the last 15 cycles.
Features
  • Epoxy potted for moisture resistance
  • Compatible with most operating controls
  • Customizable pre-time and post-time
  • Three status lights for system monitoring and diagnostics
  • Welded relay protection with redundant motor relays
  • Limited reset and limited recycle
  • Sleek, modern design
  • Technician pump prime mode
  • 18 month warranty
  • Communication ports for the GeniSys® Contractor Tool

1 - 7 of 7 Part Numbers
7580A0000U
7580A0000U
GeniSys® 7580 240V Oil Burner Control
  • Lockout Time: 15 seconds
7580B0500U
7580B0500U
GeniSys® 7580 240V Oil Burner Control
  • Lockout Time: 15 seconds
7580B1500U
7580B1500U
GeniSys® 7580 240V Oil Burner Control
  • Lockout Time: 15 seconds
  • Valve-On Delay Time: 15 seconds
7580P054MU
7580P054MU
GeniSys® 7580 240V Oil Burner Control
  • Lockout Time: 15 seconds
  • Valve-On Delay Time: 15 seconds
  • Motor-Off Delay Time: 4 minutes
7580P1515U
7580P1515U
GeniSys® 7580 240V Oil Burner Control
  • Lockout Time: 15 seconds
  • Valve-On Delay Time: 15 seconds
  • Motor-Off Delay Time: 15 seconds
7580P152MU
7580P152MU
GeniSys® 7580 240V Oil Burner Control
  • Lockout Time: 15 seconds
  • Valve-On Delay Time: 15 seconds
  • Motor-Off Delay Time: 2 minutes
7580P452MU
7580P452MU
GeniSys® 7580 240V Oil Burner Control
  • Lockout Time: 15 seconds
1 - 7 of 7 Part Numbers

Specifications

Input

  • Voltage: 208 - 240 VAC
  • Current: 100 mA plus burner motor, igniter, and valve loads

Output Voltage

  • Motor: 208/240 Vac, 5 full load amps (FLA*), 30 locked rotor amps (LRA)
  • Note: Reduce motor FLA rating by igniter current
  • Igniter: 208/240 Vac, 3 A @ 0.7 PF min
  • Solenoid Valve: 208/240 Vac, 1 A @ 0.7 PF min

Application Ratings

  • Oil Burner Input: less than 20gph

Environmental Ratings

  • Storage & Operating Ambient Temperature: -40°F to +150°F (-40°C to +65°C)
  • Moisture: 5 to 95%