3051CFP Integral Orifice Flowmeter
Brand: RosemountDesigned with an integral orifice primary element for easy installation, the Rosemount 3051CFP Integral Orifice Flow Meter is an industry-leading flow measurement solution.
This flow meter utilizes a self-centering integral orifice plate that is provided in a meter run and engineered to facilitate highly accurate flow measurement in small line sizes: 0.5 to 1.5 in. or 15 to 40 mm.
This flow meter is also leak-tested and calibrated to reduce leak points and increase process control.
Features- Complete Flow Assemblies are Leak-tested and Calibrated to Reduce Leak Points Up to 70% and Simplify Installation
- Primary Element Integrated in a Meter Run for Ease of Installation
- Orifice Plate Suitable for Small Line Sizes 0.5 to 1.5 in / 15 to 40 mm for Flow Measurement Accuracy and Repeatability
- 10-year Stability and 8:1 Flow Turndown / 150:1 Rangedown Produce Reliable Measurements and Application Flexibility
- Local Operator Interface Offers Easy-to-Use Menus and Built-in Configuration Buttons for Streamlined Commissioning
- Power Advisory Diagnostics Detect Electrical Loop Integrity Issues for Reduced Downtime
- SIL 2/3 Certified to IEC 61508: Via 3rd Party, and Prior - Use Certificate of FMEDA Data for Safety Installations
Specifications
Brand
Approvals & Certifications
- SIL 2/3 Certified to IEC 61508
Communication
- 4-20 mA HART, WirelessHART, 1-5 V Low Power HART
- FOUNDATION Fieldbus
- PROFIBUS
Measuring Range
- Up to inches WC: 1,000 (kPa: 248, bar: 2.48) Differential
NACE & NIST
- NACE
Size
- Line Size: 0.5” to 1.5” (15 to 40 mm)
Turndown
- Rangedown: up to 150: 1 (8: 1 Flow Turndown)
Wetted Materials
- 316L Stainless Steel
Documentation
Data Sheets
Product Manuals
Certificates & Approvals
- Declaration of Conformity: Rosemount 3051 Pressure Products pdf 155 KB
- Declaration of Conformity: Rosemount Annubar, ProBar, Mass ProBar, ProPlate, Mass ProPlate, 405, 1195, 1495, 1496, 1497 pdf 454 KB
- FMEDA Report: Rosemount 3051 Pressure Transmitter pdf 999 KB
- Product Certificate: Enhanced Rosemount 3051 pdf 424 KB
- Product Certificate: IEC 61508 Functional Safety Assessment for Rosemount 3051 Pressure Transmitter pdf 472 KB
- Product Certificate: Primary Elements pdf 253 KB