Model XLU11 Low Profile Load Cell
Brand: TecsisModel XLU11 tension and compression load cell features high accuracy in a small package with a low profile design for easy integration into new or existing applications.
This load cell delivers 0.1% linearity and ±0.05% repeatability over ranges from 10 to 1,000 lbs.
Standard full scale output is 2 mV/V, with inline amplification also available.
Features- High accuracy
- Low profile
- Tension/compression
1 - 11 of 11 Part Numbers
XLU11-0010
- Capacity - 10 lbs
XLU11-001K
- Capacity - 1,000 lbs
XLU11-0025
- Capacity - 25 lbs
XLU11-0050
- Capacity - 50 lbs
XLU11-0075
- Capacity - 75 lbs
XLU11-0100
- Capacity - 100 lbs
XLU11-0150
- Capacity - 150 lbs
XLU11-0200
- Capacity - 200 lbs
XLU11-0300
- Capacity - 300 lbs
XLU11-0500
- Capacity - 500 lbs
XLU11-0750
- Capacity - 750 lbs
1 - 11 of 11 Part Numbers
Specifications
Brand
Approvals & Certifications
- Calibration
- ISO 9001: 2015 Certified
Compensated Temperature
- 15° to 71° C (60° to 160° F)
Electrical Connectors
- 10 ft of 4-Conductor Cable
- Binder Series 709
Enclosure, Body Material
- Aluminum
- Stainless Steel
Excitation Voltage
- 10 Vdc
Hysteresis
- 0.1 % of FSO
Linearity
- 0.1 % of FSO
Load
- Safe Overload: 150 % of Capacity
Measuring Range
- 0 to 1,000 lb
Operating Temperature
- -53° to 93° C (-65° to 200° F)
Output
- 2 mV/V
Repeatability
- 0.05 % of FSO
Resistance
- Bridge Resistance: 350 ohms
Span & Zero Effect
- Span Effect: ± 0.005 % of Reading/°F
- Zero Effect: ± 0.005 % of FSO/°F
Zero Balance
- 1 % of FSO