Yodify Product Library
Instantly add the Master-Touch Series 8600MP-8700MP Flow Meter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Master-Touch Series 8600MP-8700MP Flow Meter
Brand: Eldridge Products, Inc (EPI)MP Series flow meters are approved for use in hazardous locations.
Inline style thermal mass flow meters include a flow section that is usually specified to match the user’s flow conduit and is then plumbed directly into the process line.
This design has the sensing elements mounted directly in the flow section for exposure to the process gas.
Our inline style thermal mass flow meters are available in sizes from 1/4″ pipe through 4″ pipe or tube, and are provided with a variety of options such as MNPT ends, tube end fittings, butt weld ends, flanged end configurations, etc. as required.
Pipe sizes in excess of 4″ typically require insertion style thermal mass flow meters. Integral style thermal mass flow meters have all of the electrical components and connections located within one enclosure.
This enclosure may be rated for either hazardous environments (MP Series) or for ordinary, non-hazardous environments (MPNH Series), as necessary.
The enclosure is mounted directly to the inline flow section or to the insertion probe assembly at the point of measurement. The enclosure includes the all of the electrical connections as well as the linearizing electronics and the display/keypad assembly.
Specifications
Accuracy
- Accuracy (Including Linearity [Referenced: 21° C (70° F)]: ± (1 % of Reading + 0.5 % of Full Scale + GTC)
Approvals & Certifications
- ATEX (For use in Hazardous Area Locations, Ta = 0° C to 50° C, IP66, Ex d IIB + H₂ T4 Gb/Ex T IIIC T135° C Db or Ex d IIB + H₂ T3 Gb/Ex T IIIC T200° C Db or Ex d IIB + H₂ T2 Gb/Ex T IIIC T300° C Db, SIRA 12-ATEX-1302)
- CSA [C-US] (For use in Hazardous Area Locations, Class I, Div. 1, Groups B, C, D, Class II Groups E, F, G Class III: Enclosure Typical 4X, Class I Zone I, AEx d IIB + H₂ IP66, Ex d IIB + H₂ IP66, T2 or T3 or T4 as Marked, Ta = 0° C to 50° C)
- IECEx (For use in Hazardous Area Locations, T2 or T3 or T4 as Marked, Ta = 0° C to 50° C, Ex d IIB + H₂ T2 to T4 Gb IP66, Ex TD A21 IP66, T135° C to T300° C, IECEx CSA 11.0014)
- KOSHA (For use in Hazardous Area Locations, Class I Groups B, C, D, Class II Groups E, F, G Class III, Enclosure Typical 4X, Class I Zone I, AEx d IIB=H₂ IP66, Ex d IIB + H₂ T2 to T4 Gb IP66, Ex TD A21 IP66)
Communication
- Signal Interface: HART
- Signal Interface: PROFIBUS DP
- Signal Interface: RS-232
- Signal Interface: RS-485 Modbus RTU Embedded
Display
- LCD (Flow Rate, Flow Total, Gas Temperature)
Environmental Protection
- IP66
- Typical 4X
Flange Size - 3” (DN 80)
- Unrated
Flange Size - 4” (DN 100)
- Unrated
Input
- Input Power Requirement: 115 Vac at 50/60 Hz
- Input Power Requirement: 230 Vac at 50/60 Hz
- Input Power Requirement: 24 Vdc at 250 mA
Length
- 6 to 14” (152.4 to 355.6 mm)
NACE & NIST
- NIST
NPT Connection
- 1” NPT Male
- 1/2” NPT Male
- 1/4” NPT Male
- 1-1/2” NPT Male
- 1-1/4” NPT Male
- 2” NPT Male
- 2-1/2” NPT Male
- 3/4” NPT Male
- 3/8” NPT Male
Output
- Linear Signal Output: 0-5 Vdc (Flow & Temperature)
- Linear Signal Output: 4-20 mA (Flow & Temperature)
Power Requirement
- Flow Transmitter Power Requirement: 5 W, Max.
- RAM Back-Up: Lithium Battery
Pressure Rating
- psi: 500 (kPa: 3,447, bar: 34.47) - Max.
Repeatability
- ± 0.2 % of Full Scale
Response Time
- Sensor: 1 second to 63 % of Final Value
Sensor, Probe Material
- Sensor: 316 Stainless Steel Sheath
- Sensor: Hastelloy C Sheath
Sensor, Probe Type
- Sensor: RTD
Temperature Coefficient
- Gas Temperature Coefficient (GTC): 0.02 % of Full Scale/°C
Temperature Range
- Environmental: -40° to 60° C (-40° to 140° F)
- Gas: -40° to 200° C (-40° to 392° F)
- Standard Temperature & Pressure (STP): 21° C (70° F) & 29.92” Hg (Air .075 lbs/ft²)
Turndown
- 100:1 at 1,500 SFPM / 7.6 NMPS Min. Full Scale
Wetted Materials
- 316 Stainless Steel
- Hastelloy