Yodify Product Library
Instantly add the Emergency Luminaire for Fluorescent Lamps for Central Battery Units EXLUX Series 6006 and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Emergency Luminaire for Fluorescent Lamps for Central Battery Units EXLUX Series 6006

Brand: R. STAHL AG

6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R.STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. 

An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
Features
  • Can be used in Ex Zones 1, 2, 21 and 22
  • Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • With address module for luminaire control and monitoring
  • Version with 2 lamps: 36 W and 58 W

1 - 11 of 11 Part Numbers
227680
227680
R. STAHL Linear Luminaire for Fluorescent Lamps for GRP Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/9.3-21
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 5 conductors 2.5 mm2

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 18 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Linear luminaire For fluorescent lamps For GRP central battery systems
  • Product Type - 6006/522-9510-11511
  • Title Product Variant Technical Data - 6006/522-9514-11511 luminai. zone1 2x18W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66/IP67
  • Design size - 2
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 700.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid, stranded
  • Version - Standard
  • Weight - 5.300 kg
  • Width - 184.000 mm
227871
227871
R. STAHL Linear Luminaire for Fluorescent Lamps for GRP Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/243-21
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 5 conductors 2.5 mm2

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Linear luminaire For fluorescent lamps For GRP central battery systems
  • Product Type - 6006/542-9510-11511
  • Title Product Variant Technical Data - 6006/542-9510-11511 luminai. zone1 2x36W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Lamp wattage - 36 W
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66/IP67
  • Design size - 4
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 1310.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid, stranded
  • Version - Standard
  • Weight - 7.690 kg
  • Width - 184.000 mm
227872
227872
R. STAHL Linear Luminaire for Fluorescent Lamps for GRP Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/963-21
  • Drilled holes - 3 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 5 conductors 2.5 mm2

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Linear luminaire For fluorescent lamps For GRP central battery systems
  • Product Type - 6006/562-9510-11511
  • Title Product Variant Technical Data - 6006/562-9510-11511 luminai. zone1 2x58W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Lamp wattage - 58 W
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66
  • Design size - 6
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 1610.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid, stranded
  • Version - Standard
  • Weight - 8.840 kg
  • Width - 184.000 mm
241217
241217
R. STAHL Linear Luminaire for Fluorescent Lamps for GRP Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/9.3-21
  • Drilled holes - 3 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - 2x SS430 stainless steel
  • Through wiring - with 5 conductors 2.5 mm2

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Linear luminaire For fluorescent lamps For GRP central battery systems
  • Product Type - 6006/522-9510-11522
  • Title Product Variant Technical Data - 6006/522-9514-11522 light. adress. 2x18W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Lamp wattage - 18 W
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66/IP67
  • Design size - 2
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 700.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid, stranded
  • Version - Standard
  • Weight - 5.500 kg
  • Width - 184.000 mm
253156
253156
R. STAHL Linear Luminaire for Fluorescent Lamps for GRP Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Ballast - 2x6042/963-21
  • Drilled holes - 4 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 5 conductors 2.5 mm2

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - ATEX (PTB), IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Linear luminaire For fluorescent lamps For GRP central battery systems
  • Product Type - 6006/562-9510-31531
  • Title Product Variant Technical Data - 6006/562-9510-31531 LumZ1 2x58W 2Circuit
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Lamp wattage - 58 W
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66
  • Design size - 6
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 1610.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid, stranded
  • Version - Standard
  • Weight - 8.840 kg
  • Width - 184.000 mm
258740
258740
R. STAHL Linear Luminaire for Fluorescent Lamps for GRP Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/243-21
  • Drilled holes - 4 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Threaded plate - 2x Plastic
  • Through wiring - with 5 conductors 2.5 mm2

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033
  • Languages of the documentation - English, German
  • Note: Through wiring - max. 3x16 A

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Linear luminaire For fluorescent lamps For GRP central battery systems
  • Product Type - 6006/542-9510-11531
  • Title Product Variant Technical Data - 6006/542-9510-11531 luminai. zone1 2x36W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Lamp wattage - 36 W
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection IP (IEC 60598) - IP66/IP67
  • Design size - 4
  • Enclosure colour - light grey (RAL 7035)
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Impact strength (IK code) - IK10 (IEC 62262)
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 1310.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Silicone
  • Type of connection cable - Finely stranded, solid, stranded
  • Version - Standard
  • Weight - 7.690 kg
  • Width - 184.000 mm
263221
263221
R. STAHL Luminaire for Fluorescent Lamps for Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +55 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/9.3-21
  • Drilled holes - 4 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - Stainless steel
  • Through wiring - with 5 conductors

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 240.00 V
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage DC - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Luminaire For fluorescent lamps For central battery systems
  • Product Type - 6006/542-9510-11542
  • Title Product Variant Technical Data - 6006/542-9510-11542 luminai. zone1 2x36W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Lamp wattage - 36 W
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 1310.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Polyurethane
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 7.700 kg
  • Width - 184.000 mm
263222
263222
R. STAHL Luminaire for Fluorescent Lamps for Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +50 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +50 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/9.3-21
  • Drilled holes - 4 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Through wiring - with 5 conductors

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Lamp wattage - 58 W
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage AC - 240.00 V
  • Rated operational voltage DC - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 50 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Luminaire For fluorescent lamps For central battery systems
  • Product Type - 6006/562-9510-11531
  • Title Product Variant Technical Data - 6006/562-9510-11531 luminai. zone1 2x58W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 1610.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Polyurethane
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 8.900 kg
  • Width - 184.000 mm
263223
263223
R. STAHL Luminaire for Fluorescent Lamps for Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
263224
263224
R. STAHL Luminaire for Fluorescent Lamps for Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +55 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/9.3-21
  • Drilled holes - 4 x M25
  • Material of screw connections - Polyamide, black
  • Screw connections - 2 x M25 Ø 7 – 17 mm
  • Stopping plug - 2 x M25 x 1.5
  • Stopping plug material - Polyamide, black
  • Through wiring - with 5 conductors

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage AC - 240.00 V
  • Rated operational voltage DC - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - IECEx (PTB), Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Luminaire For fluorescent lamps For central battery systems
  • Product Type - 6006/522-9510-11531
  • Title Product Variant Technical Data - 6006/522-9510-11531 luminai. zone1 2x18W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Lamp wattage - 18 W
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 700.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Polyurethane
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 5.500 kg
  • Width - 184.000 mm
263225
263225
R. STAHL Luminaire for Fluorescent Lamps for Central Battery Systems
Can be used in Ex Zones 1, 2, 21 and 22

Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened

Ambient Conditions

  • Ambient temperature - -20 °C ... +55 °C
  • Ambient temperature °F - -999 - -999 °F
  • Ambient temperature max. - +55 °C
  • Ambient temperature min. - -20 °C

Components

  • Address module - Stahl address module
  • Ballast - 6042/9.3-21
  • Drilled holes - 4 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - Can be ordered as accessories
  • Threaded plate - Stainless steel
  • Through wiring - with 5 conductors

Electrical Data

  • Ex version - Yes
  • Frequency range - 50 - 60 Hz
  • Rated operational voltage AC - 240.00 V
  • Rated operational voltage AC - 220.00 - 240.00 V
  • Rated operational voltage DC - 240.00 V
  • Rated operational voltage DC - 220.00 - 240.00 V

Explosion Protection

  • Ambient temperature °C - -20 - 55 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 13 ATEX 2005
  • ATEX gas certificate - PTB 13 ATEX 2005
  • Certificates - Polen (CNBOP)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC T85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex de IIC T4 Gb
  • Gas explosion protection IECEx - Ex de IIC T4 Gb
  • IECEX dust certificate - IECEx PTB13.0033
  • IECEX gas certificate - IECEx PTB13.0033

General

  • Functional Description - 6006 series EXLUX linear emergency luminaires are connected to a central battery unit of R. STAHL. They can be used as emergency lighting and for lighting escape routes and emergency exits. In the event of a power failure, they switch from two lamps to one. An address module allows the luminaires to be controlled and monitored. These luminaires are robust and lightweight, and offer a variety of installation options.
  • Highlights - Can be used in Ex Zones 1, 2, 21 and 22 Central lock for opening and closing plastic enclosure, featuring safety switch that disconnects power supply at all poles when plastic enclosure opened
  • Product Description - Luminaire For fluorescent lamps For central battery systems
  • Product Type - 6006/522-9510-11542
  • Title Product Variant Technical Data - 6006/522-9510-11542 luminai. zone1 2x18W
  • WebCode - 6006A

Lighting Data

  • Lamp - G13 lamp base
  • Lamp wattage - 18 W
  • Number of Lamps - 2

Mechanical Data

  • Connection terminals finely-stranded max. - 4.00 mm²
  • Connection terminals solid max. - 4.00 mm²
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Height - 125.000 mm
  • Installed terminal strip - PE + N + L1 + L2 + L3
  • Length - 700.000 mm
  • Material translucent cover - Polycarbonate
  • Protection class - I (with inner PE connection)
  • Sealing material - Polyurethane
  • Type of connection cable - Finely stranded, solid
  • Version - Standard
  • Weight - 5.500 kg
  • Width - 184.000 mm
1 - 11 of 11 Part Numbers