Yodify Product Library
Instantly add the HD2106 Conductivity-Thermometer and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
HD2106 Conductivity-Thermometer
Brand: Delta OHM S.R.L.HD2106.1 and HD2106.2 are portable instruments with LCD display.
They measure conductivity, liquid resistivity, total dissolved solids (TDS), and salinity using combined 4-ring and 2-ring conductivity/ temperature probes.
Temperature only is measured by Pt100 or Pt1000 immersion, penetration, contact or air probes.
The probe calibration can be performed automatically in one or more than one of the 147 μS/cm , 1413 μS/cm , 12880 μS/cm or 111800 μS/cm conductivity calibration solutions.
The temperature probes are equipped with an automatic recognition module and factory calibration data are stored inside.
The HD2106.2 is a datalogger.
It memorizes up to 36,000 conductivity and temperature samples which can be transferred from the instrument connected to a PC via the RS232C and USB 2.0 serial ports.
The storing interval, printing, and baud rate can be configured using the menu.
Both models are fitted with an RS232C serial port and can transfer to a PC the acquired measurements or to a portable printer in real time.
The Max, Min and Avg function calculates the maximum, minimum or average values.
Other functions include: the relative measurement REL, the AutoHOLD function, and the automatic turning off which can also be excluded.
The instruments have IP66 protection degree.
Specifications
Brand
Measured Quantities
- χ, Ω, TDS, NaCl, °C, °F
Conductivity Measuring Range Kcell=0.01
- 0.0000…1.999 μS/cm
- Resolution: 0.001 μS/cm
Conductivity Measuring Range Kcell=0.1
- 0.00…19.99 μS/cm
- Resolution: 0.01 μS/cm
Conductivity Measuring Range Kcell=1
- 0.0…199.9 μS/cm, Resolution 0.1 μS/cm
- 200…1999 μS/cm1, Resolution μS/cm
- 2.00…19.99 mS/cm, Resolution 0.01 mS/cm
- 20.0…199.9 mS/cm, Resolution 0.1 mS/cm
Conductivity Measuring Range Kcell=10
- 200…1999 mS/cm
- Resolution: 1 mS/cm
Accuracy (Conductivity)
- ± 0.5 % ± 1digit
Resistivity Measuring Range Kcell=0.01
- till 1 GΩ∙cm
Resistivity Measuring Range Kcell=0.1
- till 100 MΩ∙cm
Resistivity Measuring Range Kcell=1
- 5.0…199.9 Ω∙cm, Resolution 0.1 Ω∙cm
- 200…999 Ω∙cm, Resolution 1 Ω∙cm
- 1.00 k…19.99 kΩ∙cm, Resolution 0.01 kΩ∙cm
- 20.0 k…99.9 kΩ∙cm, Resolution 0.1 kΩ∙cm
- 100 k…999 kΩ∙cm, Resolution 1 kΩ∙cm
- 1…10 MΩ∙cm, Resolution 1 MΩ∙cm
Resistivity Measuring Range Kcell=10
- 0.5…5.0 Ω∙cm, Resolution 0.1 Ω∙cm
Accuracy (Resistivity)
- ± 0.5 % ± 1digit
Dissolved Solids Measuring Range Kcell=0.01
- 0.000…19.999 mg/L
- Resolution: 0.005 mg/l
Dissolved Solids Measuring Range Kcell=0.1
- 0.00…19.99 mg/L 0.05 mg/L
- Resolution: 0.05 mg/l
Dissolved Solids Measuring Range Kcell=10
- 100…999 g/l
- Resolution: 1 g/l
Accuracy (Total Dissolved Solids)
- ± 0.5 % ± 1digit
Salinity Measurement Range
- 0.000…1.999 g/L, Resolution 1 mg/L
- 2.00…19.99 g/l, Resolution 10 mg/l
- 20.0…199.9 g/l, Resolution 0.1 g/l
20.0…199.9 g/l0.1 g/l
- ± 0.5 % ± 1digit
Pt100 Measuring Range
- Pt100 measuring range
Resolution
- 0.1° C
Accuracy
- ± 0.25° C
Drift After 1 Year
- 0.1° C/year
Temperature Compensation Automatic/Manual
- 0…100° C with αT selectable from 0.00 to 4.00 %/ °C
Reference Temperature
- 20° C o 25° C
χ / TDS Conversion Factor
- 0.4…0.8
Preset Cell Constant Values: (cm-1)
- K=0.01 K=0.1 - K=0.7 - K=1 - K=10
Standard Solutions Automatically Detected at 25° C
- 147 µS/cm
- 1413 µS/cm
- 12880 µS/cm
- 111800 µS/cm
Batteries
- Four 1.5 V type AA batteries
Autonomy
- 200 hours with 1800 mAh alkaline batteries
Power Absorbed with Instrument Off
- 20 μA
Mains (SWD10)
- Output mains adapter 12 Vdc / 1A
Security of Memorized Data
- Unlimited, independent of battery charge conditions
model HD 2106.2 Type
- 2000 pages containing 18 samples each
Quantity
- 36000 pairs of measurements [χ-°C], [Ω-°C], [TDS-°C] or [Sal-°C]
Selectable Storage Interval
- 1, 5, 10, 15, 30 s
- 1, 2, 5, 10, 15, 20, 30 min
- 1 hour
Serial Interface RS-232C Type
- RS-232C electrically isolated
Baud Rate
- can be set from 1200 to 38400 baud
Data bit
- 8
Parity
- None
Stop bit
- 1
Flow Control
- Xon/Xoff
Serial Cable Length
- Maximum 15 m
Print Interval
- 1, 5, 10, 15, 30 s
- 1, 2, 5, 10, 15, 20, 30 min
- 1 hour
USB Interface - Model HD 2106.2 Type
- 1.1 - 2.0 electrically isolated
Temperature Input
- 8-Pole Male DIN 45326 Connector
Conductivity Input
- 8-Pole Male DIN 45326 Connector
Serial Interface and USB
- 8-Pole MiniUSB type B
Mains Adapter
- 2-Pole Connector (positive at centre)
Date and Time
- in real time
Time Accuracy
- 1 min/month max error
Working Temperature
- -5…50° C
Storage Temperature
- -25…65° C
Working Relative Humidity
- 0…90 % RH without condensation
Protection Degree
- IP66
Dimensions (Length x Width x Height)
- 185 x 90 x 40 mm
Weight
- 470 g (complete with batteries)
Material
- ABS, rubber
Display
- 2 x 4-1/2 digits plus symbols Visible area: 52 x 42 mm