Yodify Product Library
Add the NR10 DIN Rail Multifunction Power Meter to your store or catalog
Book Your Demo and See How
or create your store
NR10 DIN Rail Multifunction Power Meter
Brand: LUMEL S.A.NR10 is a 100A, single phase energy meter with bi-directional energy measurement ideal for Solar PV metering.
With a Modbus communication port, the unit allows for remote monitoring and can measure a wide variety of parameters.
The blue back-lighted LCD screen for perfect reading makes this device suitable for industrial, residential, and utility applications.
Features- Measures kWh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, and more
- Bi-directional measurement IMP & EXP
- Two pulse outputs
- Din Rail mounted
- 100A direct connected
- Class 1.0 accuracy
- 36mm width 2 modual
Specifications
Brand
Measured Parameters
- The unit can monitor and display the following parameters of a single phase two wire (1p2w) system.
Voltage and Current
- Phase to neutral voltages 176 to 276 Vac
- Imin-Iref (max.) 0.5-10(100 A)
Power Factor and Frequency and Maximum Demand
- Frequency in Hz
- Power 0 to 3600 MW
- Reactive power 0 to 3600 MVAr
- Volt-amps 0 to 3600 MVA
- Maximum demanded power since last Demand reset Power factor
Imported/Exported Active Energy
- 0 to 99999.99 kWh
Imported/Exported Reactive Energy
- 0 to 99999.99 kVArh
Total Active Energy
- 0 to 99999.99 kWh
Total Reactive Energy
- 0 to 99999.99 kVArh
Nominal Voltage Input
- (Ph+N) 176 to 276 V
Maximum Continuous Voltage
- 120 % of nominal
Nominal Input Current
- 0.5-10(100)A
Maximum Continuous Current
- 120 % of nominal
Nominal Input Current Burden
- 0.5 VA
Measured Input Frequency
- 50/60 Hz(± 10 %)
Voltage
- 0·5 % of Range Max.
Current
- 0·5 % of nominal
Accuracy Frequency
- 0·2 % of mid-frequency
Power Factor
- 1 % of unity (0.01)
Active Power (W)
- ± 1 % of Range Max.
Reactive Power (VAr)
- ± 1 % of Range Max.
Apparent Power (VA)
- ± 1 % of Range Max.
Active Energy (Wh)
- Class 1 IEC 62053-21
Reactive Energy (VARh)
- ± 1 % of Range Max.
Interfaces
- RS-485 communication channel that can be programmed for Modbus RTU protocol
- Relay output indicating real-time measured energy.(configurable)
Rate can be set to generate 1 pulse per
- 0.001 = 1 Wh/VArh (default)
- 0.01 = 10 Wh/VArh
- 0.1 = 100 Wh/VArh
- 1 = 1 kWh/kVArh
Pulse Width
- 200/100/60 ms.
Baud Rate
- 1200
- 2400
- 4800
- 9600
Parity
- none (default)
- odd
- even
Stop bits
- 1 or 2
RS-485 Network Address
- 3-Digit number, 1 to 247
Ambient Temperature
- 23° C ± 1° C
Input Waveform
- 50/60 Hz ± 2 %
Auxiliary Supply Voltage
- Nominal ± 1 %
Auxiliary Supply Frequency
- Nominal ± 1 %
Auxiliary Supply Waveform (if AC)
- Sinusoidal (distortion factor < 0·05)
Magnetic Field of External Origin
- Terrestrial flux
Operating Temperature
- -25° to +55° C
Storage Temperature
- -40° to +70° C
Relative Humidity
- 0 to 95 %, non-condensing
Altitude
- Up to 3000 m
Warm up Time
- 1 minute
Vibration
- 10 Hz to 50 Hz, IEC 60068-2-6, 2 g
Shock
- 30 g in 3 planes
DIN Rail Dimensions
- mm x mm (WxH) per DIN 43880
Mounting
- DIN rail (DIN 43880)
Sealing
- IP51 indoor
Material
- Self-extinguishing UL 94 V-0Energy Measurements