The monitor measures particulates in the sample stream on a continuous basis by passing the process fluid through a proprietary photo optical measuring cell developed by Rivertrace.

Using a combination of optical recognition algorithms and light intensity it is possible to differentiate between Oil particles, Gas/Air Bubbles and Solid particulates in the range 1-500 microns. Flow and particulate characteristics can be visualised live via the 7” display.

Oil concentration, pressure, temperature and oil alarm status are displayed on an HD touchscreen. Oil concentrations, alarms and fault log are stored within the system to comply with the reporting requirements of IMO resolution MEPC.107(49) and can be downloaded onto a pc via LAN or USB for further analysis.

The SMART PFM 107 offers a choice of auto cleaning methods to ensure the accuracy is maintained at all times. The cleaning is fully automatic and operates whenever it senses contamination of the optical windows.
Features
  • Oil type independent
  • Solid discrimination to MEPC.107(49)
  • Uses Microscopy to measure oil content
  • Automatic cleaning of the optical cell
  • 7″ full colour touch screen.
  • Camera display to view contaminants within the sample.

Specifications

Oil Concentration Range

  • 0 - 40 ppm

Oil Concentration Accuracy

  • ± 1 ppm

Oil Alarm 1 Operating Point

  • 15 ppm standard - (1-15 ppm adjustable)

Oil Alarm 2 Operating Point

  • 15 ppm Standard - (1-40 ppm adjustable)

Oil Alarm 1 Operating Delay

  • 1 - 2 seconds

Oil Alarm 2 Operating Delay

  • 5 - 70 seconds

Alarm Contact Rating

  • 5 Amps at 230 Vac

Alarm Relay Mode

  • De-energised in alarm state

Output Signal

  • 4-20 mA

Network Communication

  • Ethernet (RJ45)
  • Wi-Fi optional with additional hardware

IMO Data Transfer

  • USB 2 Memory stick

Ambient Temperature

  • 0° C to 55° C

Sample Temperature

  • 1° C to 60° C

Sample Flowrate

  • 0.5 to 2 l/min

Sample Pressure

  • 0.5 - 6 bars

Clean Water Requirements

  • Required

Auto Clean Pressure

  • Compressed air at 4 - 6 bar

Weight

  • 29.5 kg (65 lbs)

Standard Dimensions (mm)

  • Height: 528 mm (20.8”)
  • Width: 600 mm (23.6”)
  • Depth: 280 mm (11”)

Supply Voltage

  • 100-240 Vac

Supply Variation

  • ± 10 % of nominal voltage

Supply Frequency

  • 50/60 Hz

Power Consumption

  • 50 VA normal, 100 VA peak

Degree of Ingress Protection

  • IP65

Approvals

  • MED & MEPC.107 (49)

Display

  • 7″ LCD Display Screen

  • Drill Rig Slop Tanks
  • Oily Water Separator Discharge
  • Regulatory Compliance