Yodify Product Library
Instantly add the OLCT 10N Fixed Gas Detection and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

OLCT 10N Fixed Gas Detection

Brand: Oldham

The OLCT 10N is a digital gas detector designed for detection of the most common gases in commercial and light industrial applications. 

Intended for use in combination with the MX 43, the OLCT 10N provides a fast and accurate response. Up to 32 detectors can be connected on the same digital line or distributed on 8 lines. 

All transmitter information is received by the controller in less than 1 second. 

Non-intrusive operator interface requires only a simple magnetic wand and allows one man calibration without opening the enclosure, and calibration information, such as span reserve, is stored in the MX43. 

The OLCT 10N is IP65 and ATEX 3 GD certified, for use in ATEX 2 and 22 zones, and is water- and dustproof.
Features
  • Detection of combustible gases, toxic gases or oxygen
  • Digital technology
  • Non-intrusive calibration
  • Cost savings on wiring installation

Specifications

Brand

Approvals & Certifications

  • CE
  • EMC EN 50270
  • Ex II 3 GD, Ex NA NC IIC T4 Gc for Explosimetric Versions, Ex NA IIC T4 Gc for Others (Except CO₂ Versions), Ex Tc IIIC T135° C Dc, -20° C< Ta< 55° C
  • IECEx 11.0029X Ex NA NC IIC T4 Gc for Explosimetric Versions, Ex NA IIC T4 Gc for Others (Except CO₂ Versions), Ex Tc IIIC T135° C Dc, -20° C< Ta< 55° C
  • INERIS 11-ATEX-3023X Ex NA NC IIC T4 Gc for Explosimetric Versions, Ex NA IIC T4 Gc for Others (Except CO₂ Versions), Ex Tc IIIC T135° C Dc, -20° C< Ta< 55° C

Cable Entry

  • Cable Inlet: 2 x M16

Calibration

  • Non-Intrusive

Communication

  • Output: Proprietary Protocol
  • Output: RS-485 Modbus

Consumption

  • Catalytic Sensor: 50 mA in Normal Operation at 24 Vdc
  • CO₂ Infrared Sensor: 20 mA in Normal Operation at 24 Vdc
  • Electrochemical Sensor: 2.5 mA in Normal Operation at 24 Vdc

Diameter

  • Cable Inlet (Outer Diameter): 0.157 to 0.315” (4 to 8 mm)

Electrical Connectors

  • Up to 32 Detectors at 1,000 metres with a (18 AWG) 0.9 mm² Core Size Cable

Environmental Protection

  • IP65

Materials of Construction

  • ABS, UV & Shocks Resistant

Measuring Range

  • 0 to 10 ppm at [-20° to 50° C (-4° to 122° F) for NO₂]
  • 0 to 100 ppm at [-20° to 50° C (-4° to 122° F) for H₂S, NO] & [-20° to 40° C (-4° to 104° F) for NH₃]
  • 0 to 100 % Lower Explosive Limit (LEL) at [-20° to 55° C (-4° to 131° F) for CH₄, C₃H₈, C₄H₁₀, H₂]
  • 0 to 100 % Volume at [-40° to 50° C (-40° to 122° F) for CO₂]
  • 0 to 30 ppm at [-20° to 50° (-4° to 122° F) for H₂S, NO₂]
  • 0 to 300 ppm at [-20° to 50° C (-4° to 122° F) for CO, NO]
  • 0 to 300 ppm at [-20° to 50° C (-4° to 122° F) for CO] & [-20° to 40° C (-4° to 104° F) for NH₃]
  • 0 to 5 % Volume at [-40° to 50° C (-40° to 122° F) for CO₂]
  • 0 to 5,000 ppm at [-40° to 50° C (-40° to 122° F) for CO₂]
  • O₂: 0 to 30 % Volume at [-20° to 50° C (-4° to 122° F) for > 2-Years] & [-40° to 50° C (-40° to 122° F) for 5-Years]

Power Supply

  • 12-30 Vcc

Sensor, Probe Type

  • Sensor: Catalytic
  • Sensor: Electrochemical
  • Sensor: Infrared