Yodify Product Library
Instantly add the Isolating Repeater Loop Powered Series 9167 and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
Isolating Repeater Loop Powered Series 9167
Brand: R. STAHL AG9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example.
They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
Features- Compact, loop-powered one- and two- channel Ex i output isolating repeater
- Suitable for fire and gas detectors
- Can be used up to SIL 3 (IEC 61508)
1 - 12 of 12 Part Numbers
160238
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 1
- Open-circuit voltage U a - 15,70 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/11-11-00s
- Title Product Variant Technical Data - 9167/11-11-00s isolating repeaterw/o aux
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.161 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - No
- Load resistance R L max. - 360.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 60.0 mA
- Max. permissible external capacitance C o for IIB - 2.950 μF
- Max. permissible external capacitance C o for IIC - 0.478 μF
- Max. permissible external inductance L o for IIB - 40.000 mH
- Max. permissible external inductance L o for IIC - 10.000 mH
- Max. Power P o - 233.000 mW
- Max. Voltage U o - 15.70 V
- Safety-related maximum voltage - 253 V
160239
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 1
- Open-circuit voltage U a - 15,70 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/11-11-00k
- Title Product Variant Technical Data - 9167/11-11-00k isolating repeater w/oaux
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.161 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Load resistance R L max. - 360.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 60.0 mA
- Max. permissible external capacitance C o for IIB - 2.950 μF
- Max. permissible external capacitance C o for IIC - 0.478 μF
- Max. permissible external inductance L o for IIB - 40.000 mH
- Max. permissible external inductance L o for IIC - 10.000 mH
- Max. Power P o - 233.000 mW
- Max. Voltage U o - 15.70 V
- Safety-related maximum voltage - 253 V
160241
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 2
- Open-circuit voltage U a - 15,70 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/21-11-00s
- Title Product Variant Technical Data - 9167/21-11-00s isolating repeater w/oaux
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.182 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - No
- Load resistance R L max. - 360.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 60.0 mA
- Max. permissible external capacitance C o for IIB - 2.950 μF
- Max. permissible external capacitance C o for IIC - 0.478 μF
- Max. permissible external inductance L o for IIB - 40.000 mH
- Max. permissible external inductance L o for IIC - 10.000 mH
- Max. Power P o - 233.000 mW
- Max. Voltage U o - 15.70 V
- Safety-related maximum voltage - 253 V
160242
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 2
- Open-circuit voltage U a - 15,70 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/21-11-00k
- Title Product Variant Technical Data - 9167/21-11-00k isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.182 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Load resistance R L max. - 360.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 60.0 mA
- Max. permissible external capacitance C o for IIB - 2.950 μF
- Max. permissible external capacitance C o for IIC - 0.478 μF
- Max. permissible external inductance L o for IIB - 40.000 mH
- Max. permissible external inductance L o for IIC - 10.000 mH
- Max. Power P o - 233.000 mW
- Max. Voltage U o - 15.70 V
- Safety-related maximum voltage - 253 V
160244
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 1
- Open-circuit voltage U a - 25,00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/13-11-00s
- Title Product Variant Technical Data - 9167/13-11-00s isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.161 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - No
- Load resistance R L max. - 800.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 99.0 mA
- Max. permissible external capacitance C o for IIB - 0.840 μF
- Max. permissible external capacitance C o for IIC - 0.110 μF
- Max. permissible external inductance L o for IIB - 11.000 mH
- Max. permissible external inductance L o for IIC - 2.500 mH
- Max. Power P o - 613.000 mW
- Max. Voltage U o - 25.00 V
- Safety-related maximum voltage - 253 V
160245
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 1
- Open-circuit voltage U a - 25,00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/13-11-00k
- Title Product Variant Technical Data - 9167/13-11-00k isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.161 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Load resistance R L max. - 800.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 99.0 mA
- Max. permissible external capacitance C o for IIB - 0.840 μF
- Max. permissible external capacitance C o for IIC - 0.110 μF
- Max. permissible external inductance L o for IIB - 11.000 mH
- Max. permissible external inductance L o for IIC - 2.500 mH
- Max. Power P o - 613.000 mW
- Max. Voltage U o - 25.00 V
- Safety-related maximum voltage - 253 V
160247
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 2
- Open-circuit voltage U a - 25,00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/23-11-00s
- Title Product Variant Technical Data - 9167/23-11-00s isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.182 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - No
- Load resistance R L max. - 800.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 99.0 mA
- Max. permissible external capacitance C o for IIB - 0.840 μF
- Max. permissible external capacitance C o for IIC - 0.110 μF
- Max. permissible external inductance L o for IIB - 11.000 mH
- Max. permissible external inductance L o for IIC - 2.500 mH
- Max. Power P o - 613.000 mW
- Max. Voltage U o - 25.00 V
- Safety-related maximum voltage - 253 V
160248
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 2
- Open-circuit voltage U a - 25,00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/23-11-00k
- Title Product Variant Technical Data - 9167/23-11-00k isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.182 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Load resistance R L max. - 800.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 99.0 mA
- Max. permissible external capacitance C o for IIB - 0.840 μF
- Max. permissible external capacitance C o for IIC - 0.110 μF
- Max. permissible external inductance L o for IIB - 11.000 mH
- Max. permissible external inductance L o for IIC - 2.500 mH
- Max. Power P o - 613.000 mW
- Max. Voltage U o - 25.00 V
- Safety-related maximum voltage - 253 V
160250
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 1
- Open-circuit voltage U a - 18,80 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/14-11-00s
- Title Product Variant Technical Data - 9167/14-11-00s isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.161 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - No
- Load resistance R L max. - 590.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 107.0 mA
- Max. permissible external capacitance C o for IIB - 1.620 μF
- Max. permissible external capacitance C o for IIC - 0.266 μF
- Max. permissible external inductance L o for IIB - 12.000 mH
- Max. permissible external inductance L o for IIC - 3.000 mH
- Max. Power P o - 503.000 mW
- Max. Voltage U o - 18.80 V
- Safety-related maximum voltage - 253 V
160251
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 1
- Open-circuit voltage U a - 18,80 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/14-11-00k
- Title Product Variant Technical Data - 9167/14-11-00k isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.161 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Load resistance R L max. - 590.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 107.0 mA
- Max. permissible external capacitance C o for IIB - 1.620 μF
- Max. permissible external capacitance C o for IIC - 0.266 μF
- Max. permissible external inductance L o for IIB - 12.000 mH
- Max. permissible external inductance L o for IIC - 3.000 mH
- Max. Power P o - 503.000 mW
- Max. Voltage U o - 18.80 V
- Safety-related maximum voltage - 253 V
160253
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 2
- Open-circuit voltage U a - 18,80 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/24-11-00s
- Title Product Variant Technical Data - 9167/24-11-00s isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.182 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - horizontal vertical
- Mounting type - DIN rail (NS35/15, NS35/7.5)
Output
- LFD relay - No
- Load resistance R L max. - 590.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 107.0 mA
- Max. permissible external capacitance C o for IIB - 1.620 μF
- Max. permissible external capacitance C o for IIC - 0.266 μF
- Max. permissible external inductance L o for IIB - 12.000 mH
- Max. permissible external inductance L o for IIC - 3.000 mH
- Max. Power P o - 503.000 mW
- Max. Voltage U o - 18.80 V
- Safety-related maximum voltage - 253 V
160254
Compact, loop-powered one- and two- channel Ex i output isolating repeater
suitable for fire and gas detectors
can be used up to SIL 3 (IEC 61508)
Ambient Conditions
- Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
- Ambient temperature max. - +70 °C
- Ambient temperature max. note - Single device
- Ambient temperature max. note 2 - Group assembly
- Ambient temperature max.2 - +60 °C
- Ambient temperature min. - -20 °C
- Ambient temperature min. 2 - -20 °C
- Ambient temperature min. note - Single device
- Ambient temperature min. note 2 - Group assembly
- Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Nominal voltage - Loop-powered
- Polarity reversal protection - yes
Electrical Data
- Number of channels - 2
- Open-circuit voltage U a - 18,80 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 04 ATEX E 082 X
- ATEX gas certificate - BVS 04 ATEX E 082 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 11.0089 X
- IECEX gas certificate - IECEx BVS 11.0089 X
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - CCS, DNVGL
General
- Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
- Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
- Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
- Product Type - 9167/24-11-00k
- Title Product Variant Technical Data - 9167/24-11-00k isolating repeater w/o au
- WebCode - 9167A
Input
- Input - 0/4 ... 20 mA with HART
- Input functional range - 0 - 40 mA
- input signal - 0/4 ... 20 mA with HART
- short-circuit current - ≤ 60 mA
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 17.60 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.182 kg
Mounting / Installation
- Connection type - Spring clamp terminal
- Mounting position - horizontal vertical
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Load resistance R L max. - 590.00 Ω
- Output - 0/4 ... 20 mA with HART
- Output functional range - 0.0 - 40.0 mA
- output signal - 0/4 ... 20 mA with HART
- Settling time 10 … 90 % - ≤ 1 ms
- Temperature influence error limits - ≤ 0.1% / 10 K
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. Current I o - 107.0 mA
- Max. permissible external capacitance C o for IIB - 1.620 μF
- Max. permissible external capacitance C o for IIC - 0.266 μF
- Max. permissible external inductance L o for IIB - 12.000 mH
- Max. permissible external inductance L o for IIC - 3.000 mH
- Max. Power P o - 503.000 mW
- Max. Voltage U o - 18.80 V
- Safety-related maximum voltage - 253 V
1 - 12 of 12 Part Numbers