Brand: R. STAHL AG

9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. 

They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
Features
  • Compact, loop-powered one- and two- channel Ex i output isolating repeater
  • Suitable for fire and gas detectors
  • Can be used up to SIL 3 (IEC 61508)

1 - 12 of 12 Part Numbers
160238
160238
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 1
  • Open-circuit voltage U a - 15,70 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/11-11-00s
  • Title Product Variant Technical Data - 9167/11-11-00s isolating repeaterw/o aux
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.161 kg

Mounting / Installation

  • Connection type - Screw terminal
  • Mounting position - horizontal vertical
  • Mounting type - DIN rail (NS35/15, NS35/7.5)

Output

  • LFD relay - No
  • Load resistance R L max. - 360.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 60.0 mA
  • Max. permissible external capacitance C o for IIB - 2.950 μF
  • Max. permissible external capacitance C o for IIC - 0.478 μF
  • Max. permissible external inductance L o for IIB - 40.000 mH
  • Max. permissible external inductance L o for IIC - 10.000 mH
  • Max. Power P o - 233.000 mW
  • Max. Voltage U o - 15.70 V
  • Safety-related maximum voltage - 253 V
160239
160239
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 1
  • Open-circuit voltage U a - 15,70 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/11-11-00k
  • Title Product Variant Technical Data - 9167/11-11-00k isolating repeater w/oaux
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.161 kg

Mounting / Installation

  • Connection type - Spring clamp terminal
  • Mounting position - horizontal vertical
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Load resistance R L max. - 360.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 60.0 mA
  • Max. permissible external capacitance C o for IIB - 2.950 μF
  • Max. permissible external capacitance C o for IIC - 0.478 μF
  • Max. permissible external inductance L o for IIB - 40.000 mH
  • Max. permissible external inductance L o for IIC - 10.000 mH
  • Max. Power P o - 233.000 mW
  • Max. Voltage U o - 15.70 V
  • Safety-related maximum voltage - 253 V
160241
160241
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 2
  • Open-circuit voltage U a - 15,70 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/21-11-00s
  • Title Product Variant Technical Data - 9167/21-11-00s isolating repeater w/oaux
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.182 kg

Mounting / Installation

  • Connection type - Screw terminal
  • Mounting position - horizontal vertical
  • Mounting type - DIN rail (NS35/15, NS35/7.5)

Output

  • LFD relay - No
  • Load resistance R L max. - 360.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 60.0 mA
  • Max. permissible external capacitance C o for IIB - 2.950 μF
  • Max. permissible external capacitance C o for IIC - 0.478 μF
  • Max. permissible external inductance L o for IIB - 40.000 mH
  • Max. permissible external inductance L o for IIC - 10.000 mH
  • Max. Power P o - 233.000 mW
  • Max. Voltage U o - 15.70 V
  • Safety-related maximum voltage - 253 V
160242
160242
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 2
  • Open-circuit voltage U a - 15,70 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/21-11-00k
  • Title Product Variant Technical Data - 9167/21-11-00k isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.182 kg

Mounting / Installation

  • Connection type - Spring clamp terminal
  • Mounting position - horizontal vertical
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Load resistance R L max. - 360.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 60.0 mA
  • Max. permissible external capacitance C o for IIB - 2.950 μF
  • Max. permissible external capacitance C o for IIC - 0.478 μF
  • Max. permissible external inductance L o for IIB - 40.000 mH
  • Max. permissible external inductance L o for IIC - 10.000 mH
  • Max. Power P o - 233.000 mW
  • Max. Voltage U o - 15.70 V
  • Safety-related maximum voltage - 253 V
160244
160244
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 1
  • Open-circuit voltage U a - 25,00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/13-11-00s
  • Title Product Variant Technical Data - 9167/13-11-00s isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.161 kg

Mounting / Installation

  • Connection type - Screw terminal
  • Mounting position - horizontal vertical
  • Mounting type - DIN rail (NS35/15, NS35/7.5)

Output

  • LFD relay - No
  • Load resistance R L max. - 800.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 99.0 mA
  • Max. permissible external capacitance C o for IIB - 0.840 μF
  • Max. permissible external capacitance C o for IIC - 0.110 μF
  • Max. permissible external inductance L o for IIB - 11.000 mH
  • Max. permissible external inductance L o for IIC - 2.500 mH
  • Max. Power P o - 613.000 mW
  • Max. Voltage U o - 25.00 V
  • Safety-related maximum voltage - 253 V
160245
160245
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 1
  • Open-circuit voltage U a - 25,00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/13-11-00k
  • Title Product Variant Technical Data - 9167/13-11-00k isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.161 kg

Mounting / Installation

  • Connection type - Spring clamp terminal
  • Mounting position - horizontal vertical
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Load resistance R L max. - 800.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 99.0 mA
  • Max. permissible external capacitance C o for IIB - 0.840 μF
  • Max. permissible external capacitance C o for IIC - 0.110 μF
  • Max. permissible external inductance L o for IIB - 11.000 mH
  • Max. permissible external inductance L o for IIC - 2.500 mH
  • Max. Power P o - 613.000 mW
  • Max. Voltage U o - 25.00 V
  • Safety-related maximum voltage - 253 V
160247
160247
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 2
  • Open-circuit voltage U a - 25,00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/23-11-00s
  • Title Product Variant Technical Data - 9167/23-11-00s isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.182 kg

Mounting / Installation

  • Connection type - Screw terminal
  • Mounting position - horizontal vertical
  • Mounting type - DIN rail (NS35/15, NS35/7.5)

Output

  • LFD relay - No
  • Load resistance R L max. - 800.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 99.0 mA
  • Max. permissible external capacitance C o for IIB - 0.840 μF
  • Max. permissible external capacitance C o for IIC - 0.110 μF
  • Max. permissible external inductance L o for IIB - 11.000 mH
  • Max. permissible external inductance L o for IIC - 2.500 mH
  • Max. Power P o - 613.000 mW
  • Max. Voltage U o - 25.00 V
  • Safety-related maximum voltage - 253 V
160248
160248
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 2
  • Open-circuit voltage U a - 25,00 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/23-11-00k
  • Title Product Variant Technical Data - 9167/23-11-00k isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.182 kg

Mounting / Installation

  • Connection type - Spring clamp terminal
  • Mounting position - horizontal vertical
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Load resistance R L max. - 800.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 99.0 mA
  • Max. permissible external capacitance C o for IIB - 0.840 μF
  • Max. permissible external capacitance C o for IIC - 0.110 μF
  • Max. permissible external inductance L o for IIB - 11.000 mH
  • Max. permissible external inductance L o for IIC - 2.500 mH
  • Max. Power P o - 613.000 mW
  • Max. Voltage U o - 25.00 V
  • Safety-related maximum voltage - 253 V
160250
160250
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 1
  • Open-circuit voltage U a - 18,80 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/14-11-00s
  • Title Product Variant Technical Data - 9167/14-11-00s isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.161 kg

Mounting / Installation

  • Connection type - Screw terminal
  • Mounting position - horizontal vertical
  • Mounting type - DIN rail (NS35/15, NS35/7.5)

Output

  • LFD relay - No
  • Load resistance R L max. - 590.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 107.0 mA
  • Max. permissible external capacitance C o for IIB - 1.620 μF
  • Max. permissible external capacitance C o for IIC - 0.266 μF
  • Max. permissible external inductance L o for IIB - 12.000 mH
  • Max. permissible external inductance L o for IIC - 3.000 mH
  • Max. Power P o - 503.000 mW
  • Max. Voltage U o - 18.80 V
  • Safety-related maximum voltage - 253 V
160251
160251
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 1
  • Open-circuit voltage U a - 18,80 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/14-11-00k
  • Title Product Variant Technical Data - 9167/14-11-00k isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.161 kg

Mounting / Installation

  • Connection type - Spring clamp terminal
  • Mounting position - horizontal vertical
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Load resistance R L max. - 590.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 107.0 mA
  • Max. permissible external capacitance C o for IIB - 1.620 μF
  • Max. permissible external capacitance C o for IIC - 0.266 μF
  • Max. permissible external inductance L o for IIB - 12.000 mH
  • Max. permissible external inductance L o for IIC - 3.000 mH
  • Max. Power P o - 503.000 mW
  • Max. Voltage U o - 18.80 V
  • Safety-related maximum voltage - 253 V
160253
160253
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 2
  • Open-circuit voltage U a - 18,80 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/24-11-00s
  • Title Product Variant Technical Data - 9167/24-11-00s isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Connection cross-section - 0.2-2.5 mm² flexible 0.25-2.5 mm² flexible core end sleeve 0.2-2.5 mm² rigid
  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.182 kg

Mounting / Installation

  • Connection type - Screw terminal
  • Mounting position - horizontal vertical
  • Mounting type - DIN rail (NS35/15, NS35/7.5)

Output

  • LFD relay - No
  • Load resistance R L max. - 590.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 107.0 mA
  • Max. permissible external capacitance C o for IIB - 1.620 μF
  • Max. permissible external capacitance C o for IIC - 0.266 μF
  • Max. permissible external inductance L o for IIB - 12.000 mH
  • Max. permissible external inductance L o for IIC - 3.000 mH
  • Max. Power P o - 503.000 mW
  • Max. Voltage U o - 18.80 V
  • Safety-related maximum voltage - 253 V
160254
160254
R. STAHL Isolating Repeater without Auxiliary Power Ex I Field Circuit ISpac
Compact, loop-powered one- and two- channel Ex i output isolating repeater

suitable for fire and gas detectors

can be used up to SIL 3 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +60 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +60 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Nominal voltage - Loop-powered
  • Polarity reversal protection - yes

Electrical Data

  • Number of channels - 2
  • Open-circuit voltage U a - 18,80 V

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 04 ATEX E 082 X
  • ATEX gas certificate - BVS 04 ATEX E 082 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), Russia (Meteorological certificate), SIL (exida), USA (FM), USA (UL)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 11.0089 X
  • IECEX gas certificate - IECEx BVS 11.0089 X
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9167 series Ex i isolating repeaters operate without auxiliary power and can be used for the intrinsically safe operation of control valves, I/P transducers, analogue indicators and fire or gas detectors, for example. They have one or two channels and issue HART signals (0/4 to 20 mA) from the analogue output. They transmit superimposed HART communication signals in both directions.
  • Highlights - Compact, loop-powered one- and two- channel Ex i output isolating repeater suitable for fire and gas detectors can be used up to SIL 3 (IEC 61508)
  • Product Description - Isolating repeater Without auxiliary power Ex i field circuit ISpac
  • Product Type - 9167/24-11-00k
  • Title Product Variant Technical Data - 9167/24-11-00k isolating repeater w/o au
  • WebCode - 9167A

Input

  • Input - 0/4 ... 20 mA with HART
  • Input functional range - 0 - 40 mA
  • input signal - 0/4 ... 20 mA with HART
  • short-circuit current - ≤ 60 mA

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.182 kg

Mounting / Installation

  • Connection type - Spring clamp terminal
  • Mounting position - horizontal vertical
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Load resistance R L max. - 590.00 Ω
  • Output - 0/4 ... 20 mA with HART
  • Output functional range - 0.0 - 40.0 mA
  • output signal - 0/4 ... 20 mA with HART
  • Settling time 10 … 90 % - ≤ 1 ms
  • Temperature influence error limits - ≤ 0.1% / 10 K

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. Current I o - 107.0 mA
  • Max. permissible external capacitance C o for IIB - 1.620 μF
  • Max. permissible external capacitance C o for IIC - 0.266 μF
  • Max. permissible external inductance L o for IIB - 12.000 mH
  • Max. permissible external inductance L o for IIC - 3.000 mH
  • Max. Power P o - 503.000 mW
  • Max. Voltage U o - 18.80 V
  • Safety-related maximum voltage - 253 V