RCD Blocks - DDA200 Series
Brand: ABB GroupThe DDA Residual Current Blocks DDA200 facilitates the customers to assemble the product with S200 MCBs in order to combine the protection against indirect contacts, offered by a standard RCCBs, with the protection against short circuit and overloads.
This flexibility is an added advantage for the ones who desire to maintain the stock level at a minimum, providing a solution for wide range of applications with a handful of RCD blocks.
DDA block are mechanically manufactured to prevent an ill coupling between the block and the breaker: in fact, the rating of the block should always be greater or equal than the rating of the MCB.
The side plastic clamp permits a quicker assembly of the block on the MCBs, then a button preserves it from possible disconnections.
Features- Complete protection against all kinds of leakage currents (AC, A, B, A-APR types available)
- Rated currents from 25A up to 63 A in DDA200 and up to 100A with DDA800. The 125A are available as factory fitted RCBO s
- Sensitivities in 30mA, 100mA, 300mA, 500mA and 1A
- Selective devices
1 - 12 of 22 Part Numbers
DDA202 B APR-/
- Number of Poles - 2
DDA202 B APR-/0.3
- Number of Poles - 2
- Rated Residual Current - 300 mA
DDA202 B APR-25/0.03
- Number of Poles - 2
- Rated Residual Current - 30 mA
- Rated Current - 25 A
DDA202 B APR-25/0.3
- Number of Poles - 2
- Rated Residual Current - 300 mA
- Rated Current - 25 A
DDA202 B APR-40/0.03
- Number of Poles - 2
- Rated Residual Current - 30 mA
- Rated Current - 40 A
DDA202 B APR-63/
- Number of Poles - 2
- Rated Current - 63 A
DDA202 B APR-63/0.03
- Number of Poles - 2
- Rated Residual Current - 30 mA
- Rated Current - 63 A
DDA202 B APR-63/0.3
- Number of Poles - 2
- Rated Residual Current - 300 mA
- Rated Current - 63 A
DDA203 B APR-/
- Number of Poles - 3
DDA203 B APR-/0.03
- Number of Poles - 3
- Rated Residual Current - 30 mA
DDA203 B APR-/0.3
- Number of Poles - 3
- Rated Residual Current - 300 mA
DDA203 B APR-63/
- Number of Poles - 3
- Rated Current - 63 A
1 - 12 of 22 Part Numbers
Specifications
Brand
Number of Poles
- 2
- 3
- 4
Rated Current
- 25 A
- 40 A
- 63A
Rated Sensitivity
- 30 mA
- 300 mA
- 500 mA
Ambient Temperature
- -25° C to 55° C
Storage Temperature
- -40° C to 70° C
Electrical Life
- 10,000 Cycles
Protection Degree
- Housing: IP4X
- Terminals: IP2X