Yodify Product Library
Instantly add the Grounding Monitoring Device Series 8150 and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Grounding Monitoring Device Series 8150

Brand: R. STAHL AG

The ground monitoring device ensures that tank containers, drums, road tankers, rail cars, IBCs and helicopters are correctly electrostatically grounded during the loading of flammable liquids. 

The device provides a conductive connection to the ground and monitors in parallel the quality of the electrostatic grounding. 

This guarantees that the electrostatic charge remains at a safe level and that no explosion hazard is generated by uncontrolled energy discharge.
Features
  • Monitored electrostatic earthing of tank containers, barrels, road tankers, rail cars, and IBCs during loading
  • Continuous monitoring of correct grounding
  • Robust design
  • Weather-protected stainless steal enclosure (IP66)
  • Potential-free change-over contact for signaling to the process control system and external control devices
  • Insulated point of suspension
  • For use up to SIL 2 (IEC 61508)

1 - 1 of 1 Part Numbers
256498
256498
R. STAHL Grounding Monitoring Device Single-Channel
Monitored electrostatic earthing of tank containers, barrels, road tankers, rail cars, and IBCs during loading

Continuous monitoring of correct grounding

Robust design

Weather-protected stainless steal enclosure (IP66)

Potential-free change-over contact for signalling to the process control system and external control devices

Insulated point of suspension

For use up to SIL 2 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +55 °C
  • Ambient temperature max. - +55 °C
  • Ambient temperature min. - -20 °C
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C

Auxiliary power

  • Nominal current - 27.00 mA
  • Nominal voltage range AC - 96 - 253 V
  • Power consumption - 3.00 W

Electrical Data

  • Frequency range - 48 - 62 Hz
  • Number of channels - 1

Explosion Protection

  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 09 ATEX 1109
  • ATEX gas certificate - PTB 09 ATEX 1109
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Brazil (ULB), EAC (LPE), IECEx (PTB), India (PESO), SIL (exida), Taiwan (ITRI)
  • Dust explosion protection ATEX - II 2 D Ex tb [ia Da] IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C...T130 °C Db X
  • Dust explosion protection IECEx - Ex tb [ia Da] IIIC T80 °C Db
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 2(1) G Ex d e [ia Ga] IIC T4 Gb
  • Gas explosion protection EAC - 1 Ex e . IIA...IIC T6...T3 Gb X
  • Gas explosion protection IECEx - Ex d e [ia Ga] IIC T4 Gb
  • IECEX dust certificate - IECEx PTB 09.0049
  • IECEX gas certificate - IECEx PTB 09.0049

General

  • Application - Tank containers, barrels, IBCs, Road tankers, tank wagons
  • Functional Description - The ground monitoring device ensures that tank containers, drums, road tankers, rail cars, IBCs and helicopters are correctly electrostatically grounded during the loading of flammable liquids. The device provides a conductive connection to the ground and monitors in parallel the quality of the electrostatic grounding. This guarantees that the electrostatic charge remains at a safe level and that no explosion hazard is generated by uncontrolled energy discharge.
  • Highlights - Monitored electrostatic earthing of tank containers, barrels, road tankers, rail cars, and IBCs during loading Continuous monitoring of correct grounding Robust design Weather-protected stainless steal enclosure (IP66) Potential-free change-over contact for signalling to the process control system and external control devices Insulated point of suspension For use up to SIL 2 (IEC 61508)
  • Product Description - Grounding monitoring device Single-channel
  • Product Type - 8150/5-V75
  • Title Product Variant Technical Data - 8150/5-V75 Grounding monitoring device
  • WebCode - 8150G

Mechanical Data

  • Cable diameter range of cable glands - 4.0 - 13.0 mm
  • Degree of protection (IP) - IP66
  • Depth - 107.000 mm
  • Enclosure material - 1.4404 stainless steel
  • Height - 177.000 mm
  • Weight - 6.580 kg
  • Width - 436.000 mm

Output

  • Application - Tank containers, barrels, IBCs
  • Limit contact (per channel) - Change-over contact
  • Output max. load AC - 250 V / 4 A
  • Output max. load DC - 250 V / 2 A
  • Output min. load - 12 V / 100 µA
1 - 1 of 1 Part Numbers