Yodify Product Library
Instantly add the SCK Gas Sampling for Cement Kiln and Calciner Gas Exit and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
SCK Gas Sampling for Cement Kiln and Calciner Gas Exit
Brand: ABB GroupThe SCK is a sampling system for dry gas sampling at rotary kiln exit and calciner gas exit. The SCK sampling system is suitable for applications in rough environmental conditions and for outdoor installations thanks to a complete protection cover.
The development of the SCK is based on ABB's experience gained from its successful predecessors, of which more than 500 systems have been supplied worldwide.
The SCK sampling system is preferably combined with ABB's ACX gas analyzer system for effective monitoring and control of the primary and secondary combustion.
SCK can also be ordered separately to replace and modernize just a sampling system. It will be delivered completely preassembled to the installation site.
Features- Complete sampling system comprising of only three preassembled modules
- Pneumatically driven probe retractor with dust cover and automatic oven flap
- Unique selection of two process proven probes: Probe H and Probe 60S
- Automatic cyclic cleaning of probe and filter
- Cable drag chain for bundled cables and tubes
- Control unit with touch panel featuring comprehensive operation, diagnosis and maintenance capacities
- Sophisticated tools for complete remote operation and remote diagnosis available
- Ethernet and Profibus networking, USB interface for data collection and remote support.
- Easy system setup due to reduced cabling and mounting parts
Specifications
Brand
Material of Construction
- Sheet Steel
Color
- Light Gray (RAL 7035)
Environmental Protection
- IP54
Mounting
- Wall Mounting
Power Supply
- 3-Phase, 230/400 Vac, ± 10 %, 50/60 Hz
- 3-Phase, 3 x 208 Vac, ± 10 %, 60 Hz including transformer
- UPS: 230 Vac or 120 Vac, ± 10 %, 50 to 60 Hz
Power Consumption
- Maximum 6 kVA
Air Consumption
- Approximately 3 m³/h (1.7 cfm) Standard
Ambient Temperature
- 5° to 45° C (41° to 113° F), -20° to 45° C (-4° to 113° F) with anti-freeze agent in the Cooling water
- Compressed Air tank (Option): -10° to 50° C (-14° to 122° F)
Storage / Transport Temperature
- 5° to 55° C (41° to 131° F), -20° to 55° C (-4° to 131° F) after draining and drying all Parts in Contact with Cooling water or condensate
Humidity
- ≤ 75 % Relative Humidity Annual Average
Process Gas Pressure
- ± 3 kPa (0.435 psi)
Process Gas Temperature
- Maximum 1,300° C (2,372° F)
Dust Load
- Maximum 2,000 g/m³ (874 grain/ft³)