HydroACT Analyzer with DuraTrac 4 Sensor

Brand: Chemtrac

Optimize coagulation with the latest generation Streaming Current Monitor from Chemtrac. The DuraTrac 4 Streaming Current Sensor is combined with the HydroACT Analyzer to deliver state-of-the-art charge measurement capabilities for water treatment plants.

Modbus RTU, Modbus TCP, or analog outputs, allow for direct communication with SCADA systems. And the PID control option provides for direct chemical feed pump control to maintain optimum coagulant or polymer dosages.

The DT4 has a unique Signal Health Detection feature for performance troubleshooting, and the sensor probe can be rebuilt without being replaced.

In addition to streaming current, the HydroACT can also monitor pH, UV254 organics, and Turbidity (NTU), to provide a complete coagulation monitoring and control system.
Features
  • Includes analyzer, DuraTrac 4 sensor, 1 analog output, and 25 feet of interconnect cable 
  • 0.2 to 10 gpm sample flow capability 
  • Quick-replacement, user serviceable parts
  • Easy push button zero offset 
  • Advanced signal health diagnostics 
  • Optional:
    • Expandable sensor inputs and I/O 
    • Up to 1000 feet of interconnect cable
    • Chemical feed control outputs 
    • Data logging with MicroSD download
    • Modbus or PROFIBUS communications 
    • Color display 
    • Remote (internet) access 
  • Capability of incorporating multiple measurements that are key to coagulation, such as pH, TSS/NTU, and UV254 organics
  • Multiple chemical feed control options with overfeed protection, start delay, setpoint ramping, and other advanced features 
  • State of the art features like signal health diagnostics and pH compensation provides improved

Specifications

Brand

Range

Sample Flow Rate

  • 1 to 40 L/min

Repeatability

  • Better than 2 % from (10 to 250 µS)
  • Better than 3 % from (250 to 500 µS)
  • Better than 5 % from (500 to 1,000 µS)

Maximum Operating Pressure

  • 20 psi

Operating Temperature

  • 34° to 120° F (1° to 49° C)

Probe Type

  • Quick-Replacement Cartridge With Replaceable Sleeve

Sample Connection

  • 1” FNPT

Enclosure/Body Material

  • Fiberglass Reinforced

Environmental Protection

  • NEMA 4X

Power Requirement

  • 110 Vac, 1 A, 60 Hz
  • 220 Vac, 1 A, 50 Hz Optional

Materials Contacting Sample

  • Delrin, Viton, Stainless Steel

  • Water Treatment
  • Wastewater Treatment
  • Papermaking 