Brand: Calex Electronics Limited

Extremely small measured spot size. 

Applications include measuring individual electronic component temperatures on a circuit board, and plastic welding where the seam is very narrow.
Features
  • Temperature ranges from 0° to 500° C
  • Response time as fast as 10 Milliseconds
  • Continuous LED sighting shows the position and size of the measured spot while readings are being taken
  • Multilingual touch screen interface (optional)
  • Measured spot as small as 0.7 mm

1 - 12 of 18 Part Numbers
PCU-XSA0.7-10M-10V
PCU-XSA0.7-10M-10V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 10 metres
  • Output - 0-10 Vdc
PCU-XSA0.7-10M-1V
PCU-XSA0.7-10M-1V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 10 metres
  • Output - 0-1 Vdc
PCU-XSA0.7-10M-5V
PCU-XSA0.7-10M-5V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 10 metres
  • Output - 0-5 Vdc
PCU-XSA0.7-2M-10V
PCU-XSA0.7-2M-10V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 2 metres
  • Output - 0-10 Vdc
PCU-XSA0.7-2M-1V
PCU-XSA0.7-2M-1V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 2 metres
  • Output - 0-1 Vdc
PCU-XSA0.7-2M-5V
PCU-XSA0.7-2M-5V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 2 metres
  • Output - 0-5 Vdc
PCU-XSA0.7-5M-10V
PCU-XSA0.7-5M-10V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 5 metres
  • Output - 0-10 Vdc
PCU-XSA0.7-5M-1V
PCU-XSA0.7-5M-1V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 5 metres
  • Output - 0-1 Vdc
PCU-XSA0.7-5M-5V
PCU-XSA0.7-5M-5V
  • Field of View - 0.7 mm Measured Spot Diameter at 40 mm Distance
  • Cable Length - 5 metres
  • Output - 0-5 Vdc
PCU-XSB1.0-10M-10V
PCU-XSB1.0-10M-10V
  • Field of View - 1 mm Measured Spot Diameter at 100 mm Distance
  • Cable Length - 10 metres
  • Output - 0-10 Vdc
PCU-XSB1.0-10M-1V
PCU-XSB1.0-10M-1V
  • Field of View - 1 mm Measured Spot Diameter at 100 mm Distance
  • Cable Length - 10 metres
  • Output - 0-1 Vdc
PCU-XSB1.0-10M-5V
PCU-XSB1.0-10M-5V
  • Field of View - 1 mm Measured Spot Diameter at 100 mm Distance
  • Cable Length - 10 metres
  • Output - 0-5 Vdc
1 - 12 of 18 Part Numbers

Specifications

Accuracy

  • ± 3° C (± 5.4° F) or 1 %, whichever is greater - XSA Model
  • ± 5° C (± 9° F) - XSB Model

Alarm

  • 1 Open Drain Alarm Output, Rated 27 Vdc, 0.2 A

Ambient Temperature Range

  • 0° to 50° C (32° to 122° F) - Operating Ambient Temperature

Applications

  • Measure the Temperature of Extremely Small Areas at 0° to 500° C

Cable Length

  • 16.40 feet (5 metres)
  • 32.81 feet (10 metres)
  • 6.56 feet (2 metres)

Communication

  • Data Logging: Interval 1 second to 1 Day
  • Modbus RTU, Non-Isolated
  • RS-232C

Display

  • 2.83” (72 mm) Resistive Touch TFT
  • 320 x 240 Pixels
  • Backlit

Environmental Protection

  • IP67

Humidity

  • 30 to 85 % Relative Humidity, Non-Condensing

Output

  • 0-1 Vdc
  • 0-10 Vdc
  • 0-20 mA
  • 0-5 Vdc
  • 4-20 mA

Output Format

  • Alarm Output
  • Analog Output

Repeatability

  • ± 1° C (± 1.8° F) - XSA Model
  • ± 2° C (± 3.6° F) - XSB Model

Resolution

  • 0.5° C Above 50° C (122° F) - XSA Model
  • 1.5° C Above 100° C (212° F) - XSB Model
  • 1° C Below 50° C (122° F) - XSA Model
  • 3° C Below 100° C (212° F) - XSB Model

Response Time

  • 10 milliseconds - XSA Model
  • 50 milliseconds - XSB Model

Storage Temperature

  • -15° to 70° C (5° to 158° F)

Supply Voltage

  • 5-27 Vdc, 100 mA - Max.

Temperature Range

  • 0° to 500° C (32° to 932° F)