Brand: R. STAHL AGR. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
Features- Ammeters in various versions, for Ex e enclosures
- Quicker comparison of measured values using externally adjustable red pointers on the device
- Selection of different current measuring ranges
1 - 8 of 8 Part Numbers
262936
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 1 / 2 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 1 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 1.000 - 1.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8405/6-1-2
- Title Product Variant Technical Data - 8405/6-1-2 Ammeter direct display
- WebCode - 8405B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 48.000 mm
- Enclosure material - Polycarbonate
- Height - 51.500 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.120 kg
- Width - 48.000 mm
262937
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 4 / 8 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 4 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 4.000 - 4.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8405/6-4-2
- Title Product Variant Technical Data - 8405/6-4-2 Ammeter direct display
- WebCode - 8405B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 48.000 mm
- Enclosure material - Polycarbonate
- Height - 51.500 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.120 kg
- Width - 48.000 mm
262938
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 10 / 20 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 10 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 10.000 - 10.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb mb IIC Gb
- Gas explosion protection IECEx - Ex eb mb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8405/6-10-2
- Title Product Variant Technical Data - 8405/6-10-2 Ammeter direct display
- WebCode - 8405B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 48.000 mm
- Enclosure material - Polycarbonate
- Height - 51.500 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.120 kg
- Width - 48.000 mm
262939
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 15 / 30 A
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 15 A
- Measuring range min. - 0 A
- Overload capacity - 30 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 15.000 - 15.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb mb IIC Gb
- Gas explosion protection IECEx - Ex eb mb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges
- Product Description - Moving iron ammeter direct measuring
- Product Type - 8405/6-15-2
- Title Product Variant Technical Data - 8405/6-15-2 Ammeter direct display
- WebCode - 8405B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 4.00 mm²
- Degree of protection (IP) - IP54
- Depth - 48.000 mm
- Enclosure material - Polycarbonate
- Height - 51.500 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.120 kg
- Width - 48.000 mm
262940
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 1 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 1.000 - 1.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges
- Product Description - Moving iron ammeter For transducer
- Product Type - 8405/6-1T-2
- Title Product Variant Technical Data - 8405/6-1T-2 Converter Ammeter Ue=2
- WebCode - 8405B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 48.000 mm
- Enclosure material - Polycarbonate
- Height - 51.500 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.120 kg
- Width - 48.000 mm
262941
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 1 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 1.000 - 1.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges
- Product Description - Moving iron ammeter For transducer
- Product Type - 8405/6-1T-5
- Title Product Variant Technical Data - 8405/6-1T-5 Converter Ammeter Ue=5
- WebCode - 8405B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 48.000 mm
- Enclosure material - Polycarbonate
- Height - 51.500 mm
- Overload scale - 5x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.120 kg
- Width - 48.000 mm
262942
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 5 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 5.000 - 5.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges
- Product Description - Moving iron ammeter For transducer
- Product Type - 8405/6-5T-2
- Title Product Variant Technical Data - 8405/6-5T-2 Converter Ammeter Ue=2
- WebCode - 8405B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 48.000 mm
- Enclosure material - Polycarbonate
- Height - 51.500 mm
- Overload scale - 2x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.120 kg
- Width - 48.000 mm
262943
Ammeters in various versions, for Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Frequency - 0/100 Hz
- Measuring range max. - 5 A
- Measuring range min. - 0 A
- Overload capacity - 50 x IN 1 sec
- Power dissipation - 0.670 VA
- Rated operational current AC - 5.000 - 5.000 A
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 17 ATEX 192 U
- Gas explosion protection ATEX - II 2 G Ex eb IIC Gb
- Gas explosion protection IECEx - Ex eb IIC Gb
- IECEX gas certificate - IECEx SIQ 17.0003U
General
- Functional Description - R. STAHL Series 8405 ammeters are installed in Ex e type of protection enclosures. They provide measured values for circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges
- Product Description - Moving iron ammeter For transducer
- Product Type - 8405/6-5T-5
- Title Product Variant Technical Data - 8405/6-5T-5 Converter Ammeter Ue=5
- WebCode - 8405B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 6.00 mm²
- Connection cross-section solid max. - 10.00 mm²
- Connection cross-section solid min. - 2.50 mm²
- Degree of protection (IP) - IP54
- Depth - 48.000 mm
- Enclosure material - Polycarbonate
- Height - 51.500 mm
- Overload scale - 5x
- Silicone-free - No
- Terminal degree of protection (IP) - IP20
- Weight - 0.120 kg
- Width - 48.000 mm
1 - 8 of 8 Part Numbers