Yodify Product Library
Instantly add the NUFLO MC-III Panel Mount Flow Analyzer and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
NUFLO MC-III Panel Mount Flow Analyzer
Brand: CameronCameron’s NuFlo MC-III Panel Mount Flow Analyzer offers state-of-the art liquid and gas measurement with data logging and Modbus communications in an easy-to-use totalizer with a standard 1/4-DIN mount.
With the capacity to record up to 384 daily flow logs, 768 hourly logs and 345 event logs, the MC-III is a powerful addition to any flow measurement operation.
Specifications
Brand
Display
- Eight-digit display of total
- Six-digit display of rate (11-segment characters for easy-to-read prompts)
- Character height - 0.300”
- Adjustable contrast and update period
User-Selectable Units of Measurement
- Total: bbl, gal, liters, cubic meters, cubic feet, standard cubic feet, user-defined units (and all units x 1000)
- Rate: Any of the above total volume units per day, hour, minute or second
Power Supply Options
- 3.6 VDC lithium battery pack: Two-year typical life (main or backup power supply); Transport is subject to hazardous goods restrictions
- External power supply (6 to 30 VDC) with internal battery backup
- Loop-powered (4 to 20 mA output) with internal battery backup
Temperature Range
- -40°F to 158°F (-40°C to 70°C)
- LCD Contrast is reduced below -4°F (-20°C)
Mounting
- Standard ¼-DIN (3.62” x 3.62”)
Turbine Meter Input
- Configurable Sensitivity Adjustment
- Frequency Range: 0 to 3500 Hz
Remote Reset Input
- Optically Isolated
- Supply Range: 3.0 to 30 VDC
Pulse Input
- Optically Isolated
- Supply Range: 3.0 to 30 VDC
Analog Output
- Loop Power: 8.0 to 30 VDC
- Zero and full-scale engineering values configurable from front panel
- Accuracy: 0.1% of FS at 77°F (25°C), 50 PPM/°C Temperature Drift
- 16-bit Resolution
- 4 to 20 mA, Loop-Powered (Two-Wire)
RS-485 Communications
- Baud rates: 300, 600, 1200, 2400, 4800,9600, 19200, 38400, 57600 and up to 115.2K
Volumetric Pulse Output
- Solid-State Relay
- Output Rating: 60 mA max at 30 VDC
- Configurable pulse duration and scale factor
Amp and Square Output
- Open-drain transistor output of turbine meter input signal
- Output rating: 50 mA at 30 VDC (analog output and amp and square outputs cannot be used simultaneously)
Communications/Archive Retrieval
- RTU mode Modbus
- Enron Modbus
- 16-bit slave address supported
- Data printouts in tabular or chart formats
- Data export to spreadsheet (.xls and .csv formats)