Brand: Fireye, IncThe Fireye® NXF4000 is an advanced burner management controller with internal flame safeguard, designed to operate burners firing liquid or gaseous fuels.
NXF4000 supports up to 4 servos per profile plus 2 VFD channels, touchscreen interface, 15 configurable user input, valve proving, thermal shock protection, etc.
Add-on options include oxygen trim, plant master for centralized control and communication gateway to support most BMS/PLC/SCADA needs.
Features- Increased Efficiency
- Reduce fuel consumption
- Reduce emissions & Greenhouse gases
- Reduce downtime & maintenance
1 - 2 of 2 Part Numbers
1 - 2 of 2 Part Numbers
Specifications
Brand
Ambient Temperature Range
- 0° to 60° C (32° to 140° F)
Approvals & Certifications
- FM
- UL (C,US)
Consumption
- Power Consumption: Approximately 15 VA (with Display Attached & No Accessories)
Load
- Display: 6 VA
- FX04: 5 VA
- FX20: 15 VA
- FX50: 20 VA
- O₂ Probe: 12 VA Typical
Supply Voltage
- 120/230 Vac, 50/60 Hz
Documentation
Data Sheets
Application Diagrams
Certificates
Manuals
- Fireye FX Series - Modbus Controlled Actuator/Servo Installation and Operating Instructions, NEX-3001 pdf 2.5 MB
- FXIATS-140 Ambient Air Temperature Transmitter, FXIATS-1 pdf 244 KB
- Nexus PPC4000/NXF4000 Modbus Communications, MOD-4001 pdf 74 KB
- NXCESO2 Oxygen Probe, NXCESO2-1001 pdf 723 KB
- NXCESUV, NXCESIR, NXCESDC Plug-In Amplifier Card, NXCESAMP-1001 pdf 160 KB
- NXF-4100 - NXF4000 and PPC4000 Fuel-Air Ratio Controllers (English) pdf 12.0 MB
- Type2 Oxygen probe system for NEXUS NXF4000 and PPC4000, FXCESO2-1001 pdf 709 KB
Presentations
- NXF4000 Setup and Commissioning pdf 22.0 MB
- PR-00-2-0100-0-003 - Burner Control Basics pdf 1.7 MB
- PR-00-2-0100-010 - Connecting a VFD to a Nexus pdf 2.7 MB
- PR-00-2-0200-0-011-A - Verifying the Integrity of the Gas Train pdf 3.1 MB
- PR-00-2-0500-0-008 - Introduction to NXF4000 pdf 4.1 MB
- PR-00-2-1000-0-006 - Methods of Flame Detection pdf 2.5 MB
- Programming Inputs and Outputs on an NXF4000 or PPC4000 pdf 4.7 MB
Product Overview
Product Specifications
Service Guide
- ACS550 Wiring and Parameters for Nexus Controls (Non-Bypass) pdf 701 KB
- ACS580 Wiring and Parameters for Nexus Controls (Non-Bypass) pdf 456 KB
- Connecting Externally Proven Devices to NXF4000 pdf 220 KB
- Connecting Two Modbus Masters to an NXF4000 or PPC4000 pdf 373 KB
- Fireye Local/Remote Firing Rate Adapter for the NXF4000 and PPC4000 pdf 553 KB
- First-out Annunciation with the NXF4000 pdf 276 KB
- NXTSD4xx Touchscreen Installation Guide, NXTSD-4001 pdf 500 KB
- NXTSD4xx Touchscreen Operators Guide, NXTSD-4002 pdf 4.0 MB
- Using a Common Header Sensor for Two-Boiler Sequencing pdf 222 KB
- Using a Symmetrical Timer to Alternate Lead with Two-Boiler Sequencing pdf 214 KB
- Using External End Switches with an NXF4000 pdf 317 KB
- Using Hot Standby on Steam Boilers pdf 396 KB
Technical Instructions
- 129-190 Cooling Fan Replacement Kit, 133-763 pdf 85 KB
- 133-789 - 60-3004 Terminal Block Kit NXF4000 PPC-4000 (English) pdf 23 KB
- 35-381-2 O2 Probe Mounting Flange, 133-750 pdf 185 KB
- Cable for NXD410 User Interface, 133-745 pdf 72 KB
- Field Wireable Connector for use with FX04-1, FX20-1, FX50-1 Servos, 133-747 pdf 77 KB
- Low Fire Hold Release to Modulate Stack Temperature 4000 Series pdf 130 KB
- Replacement cartridge for NXCESO2 Probe, 133-751 pdf 123 KB
- S7999B - D NXD410TS Cutout Dimensions pdf 76 KB
- S7999B - D NXD410TS Cutout Template Actual Size pdf 32 KB
- Servo Connector Kit for FX04, FX20, FX50, 133-755 pdf 213 KB
- Special instructions for using Nexus NXTSD407 & NXTSD413 Displays, 133-765 pdf 346 KB