Yodify Product Library
Add the NXF4000 Advanced Burner Management System Controller to your store or catalog
Book Your Demo and See How
or create your store
NXF4000 Advanced Burner Management System Controller
Brand: Fireye, IncThe Fireye® NXF4000 is an advanced burner management controller with internal flame safeguard, designed to operate burners firing liquid or gaseous fuels.
NXF4000 supports up to 4 servos per profile plus 2 VFD channels, touchscreen interface, 15 configurable user input, valve proving, thermal shock protection, etc.
Add-on options include oxygen trim, plant master for centralized control and communication gateway to support most BMS/PLC/SCADA needs.
Features- Increased Efficiency
- Reduce fuel consumption
- Reduce emissions & Greenhouse gases
- Reduce downtime & maintenance
1 - 2 of 2 Part Numbers
1 - 2 of 2 Part Numbers
Specifications
Brand
Ambient Temperature Range
- 0° to 60° C (32° to 140° F)
Approvals & Certifications
- FM
- UL (C,US)
Consumption
- Power Consumption: Approximately 15 VA (with Display Attached & No Accessories)
Load
- Display: 6 VA
- FX04: 5 VA
- FX20: 15 VA
- FX50: 20 VA
- O₂ Probe: 12 VA Typical
Supply Voltage
- 120/230 Vac, 50/60 Hz
Documentation
Data Sheets
Application Diagrams
Certificates
Manuals
- Fireye FX Series - Modbus Controlled Actuator/Servo Installation and Operating Instructions, NEX-3001 pdf 2.5 MB
- FXIATS-140 Ambient Air Temperature Transmitter, FXIATS-1 pdf 244 KB
- Nexus PPC4000/NXF4000 Modbus Communications, MOD-4001 pdf 74 KB
- NXCESO2 Oxygen Probe, NXCESO2-1001 pdf 723 KB
- NXCESUV, NXCESIR, NXCESDC Plug-In Amplifier Card, NXCESAMP-1001 pdf 160 KB
- NXF-4100 - NXF4000 and PPC4000 Fuel-Air Ratio Controllers (English) pdf 12.0 MB
- Type2 Oxygen probe system for NEXUS NXF4000 and PPC4000, FXCESO2-1001 pdf 709 KB
Presentations
- NXF4000 Setup and Commissioning pdf 22.0 MB
- PR-00-2-0100-0-003 - Burner Control Basics pdf 1.7 MB
- PR-00-2-0100-010 - Connecting a VFD to a Nexus pdf 2.7 MB
- PR-00-2-0200-0-011-A - Verifying the Integrity of the Gas Train pdf 3.1 MB
- PR-00-2-0500-0-008 - Introduction to NXF4000 pdf 4.1 MB
- PR-00-2-1000-0-006 - Methods of Flame Detection pdf 2.5 MB
- Programming Inputs and Outputs on an NXF4000 or PPC4000 pdf 4.7 MB
Product Overview
Product Specifications
Service Guide
- ACS550 Wiring and Parameters for Nexus Controls (Non-Bypass) pdf 701 KB
- ACS580 Wiring and Parameters for Nexus Controls (Non-Bypass) pdf 456 KB
- Connecting Externally Proven Devices to NXF4000 pdf 220 KB
- Connecting Two Modbus Masters to an NXF4000 or PPC4000 pdf 373 KB
- Fireye Local/Remote Firing Rate Adapter for the NXF4000 and PPC4000 pdf 553 KB
- First-out Annunciation with the NXF4000 pdf 276 KB
- NXTSD4xx Touchscreen Installation Guide, NXTSD-4001 pdf 500 KB
- NXTSD4xx Touchscreen Operators Guide, NXTSD-4002 pdf 4.0 MB
- Using a Common Header Sensor for Two-Boiler Sequencing pdf 222 KB
- Using a Symmetrical Timer to Alternate Lead with Two-Boiler Sequencing pdf 214 KB
- Using External End Switches with an NXF4000 pdf 317 KB
- Using Hot Standby on Steam Boilers pdf 396 KB
Technical Instructions
- 129-190 Cooling Fan Replacement Kit, 133-763 pdf 85 KB
- 133-789 - 60-3004 Terminal Block Kit NXF4000 PPC-4000 (English) pdf 23 KB
- 35-381-2 O2 Probe Mounting Flange, 133-750 pdf 185 KB
- Cable for NXD410 User Interface, 133-745 pdf 72 KB
- Field Wireable Connector for use with FX04-1, FX20-1, FX50-1 Servos, 133-747 pdf 77 KB
- Low Fire Hold Release to Modulate Stack Temperature 4000 Series pdf 130 KB
- Replacement cartridge for NXCESO2 Probe, 133-751 pdf 123 KB
- S7999B - D NXD410TS Cutout Dimensions pdf 76 KB
- S7999B - D NXD410TS Cutout Template Actual Size pdf 32 KB
- Servo Connector Kit for FX04, FX20, FX50, 133-755 pdf 213 KB
- Special instructions for using Nexus NXTSD407 & NXTSD413 Displays, 133-765 pdf 346 KB