876 Series Barometric Pressure Transducer

Brand: Gems Sensors, Inc

The 876 Series features an extremely accurate and stable ceramic sensor to deliver a great value in environmental pressure measurement.

Gems glass-fused ceramic capacitive sensing capsule offers inherent thermal stability and low hysteresis in a proven, simple design. 

A custom ASIC used in the 876 Series achieves long-term stability and high accuracy, and its low power requirements (as low as 5 Vdc) allow the sensor to operate in remote battery or solar powered applications.

An integrated mounting bracket and 1/8" tube pressure connection ease installation.
Features
  • Instant Warm-Up
  • Barometric Pressure: 600 to 1100 or 800 to 1100 hPa/mb
  • Low Power Consumption (for Battery or Solar Power)

Specifications

Accuracy

  • ± 0.25 % of Full Scale

Applications

  • Automotive Emissions Test Equipment
  • Barometric Pressure Compensation for Internal Combustion Engine Performance
  • Cleanroom barometric Pressure Compensation
  • Environmental Monitoring System
  • Weather & Environmental Data
  • Weather Measurement System

Approvals & Certifications

  • CE

Cable Length

  • 2 to 10 ft (0.6 to 3 m)

Compensated Temperature

  • 0° to 55° C (30° to 130° F)

Constant Acceleration

  • 10 G

Electrical Connectors

  • 2 ft Multiconductor Cable

Enclosure, Body Material

  • Stainless Steel with Mounting Bracket

Excitation Voltage

  • 5-24 Vdc

NPT Connection

  • 1/8" NPT

Operating Temperature

  • -18° to 79° C (0° to 175° F)

Output

  • 0.1-5.1 Vdc (3-Wire)
  • 0.5 - 4.5 Vdc, 3 - wire

Pressure Cycles

  • Fatigue Life > 1 Million Cycles

Pressure Range

  • bar: 0 to 1.379
  • kPa: 0 to 137.9
  • psia: 0 to 20

Proof Pressure

  • psia: 20 (kPa: 137.9, bar: 1.37)
  • psia: 30 (kPa: 206.8, bar: 2.1) for 20 psia Range

Shock

  • 50 G (Operating, 1/2 Sine 10 mg)

Span & Zero Effect

  • Thermal: 1 % of Full Scale

Storage Temperature

  • -55° to 121° C (-65° to 250° F)

Supply Voltage

  • 4.9-26 Vdc

Thermal Drift

  • Long Term Drift: 0.25 % of Full Scale/6 Months

Tolerance

  • Span Tolerance: ± 50 mV
  • Zero Tolerance: ± 25 mV

Tube Connection

  • 1/8" Tube Fitting

Vibration

  • 2 G from 5 to 400 Hz

Wetted Materials

  • Alumina Ceramics
  • Elastomer
  • Gold
  • Stainless Steel

  • Environmental Monitoring Systems
  • Weather Measurement Systems
  • Weather and Environmental Data Logging
  • Barometric Pressure Compensation for Internal Combustion Engine Performance
  • Cleanroom Barometric Pressure Compensation
  • Automotive Emissions Test Equipment

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more