TH Analog SIL 2 Capable Magnetostrictive Linear Position Sensor
Brand: Temposonics an Amphenol CompanyThe TH sensor is extremely robust and ideal for continuous operation under harsh industrial conditions.
T-Series sensors are ATEX, IECEx, CEC and NEC certified for use in Class I, II, III Division 1, Division 2 and Zone 0/1, Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas and meet the requirements for SIL 2.
The T-Series is offered in a ϕ 10 mm (ϕ 0.39") rod in lengths from 25 to 1,500 mm (1 to 60"). The sensor rod is capable of withstanding high pressures such as those found in hydraulic cylinders.
Furthermore the sensor is also suitable for petrochemical plants and caustic environments. The sensor head contains the active signal conditioning and a complete integrated electronics interface.
Specifications
Approvals & Certifications
- ISO 9001 (DQS)
- ATEX Ex db Eb IIC T4 Ga/Gb, Ex Tb IIIC T130° C Ga/Db Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 85° C (Version E), Ex db IIC T4 Ga/Gb Ex Tb IIIC T130° C Ga/Db Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 85° C (Version D, G)
- CEC - Version E (Non-Incendive, Non-Sparking), Version G (Explosion-proof, Flameproof)
- EMC Electromagnetic Emission IEC, EN 61326-1 (Class B), Immunity IEC, EN 61326-2-3 (Class B)
- IEC Ex db Eb IIC T4 Ga/Gb, Ex Tb IIIC T130° C Ga/Db Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 85° C (Version E), Ex db IIC T4 Ga/Gb Ex Tb IIIC T130° C Ga/Db Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 85° C (Version D, G)
- NEC - Version E (Non-Incendive, Non-Sparking), Version G (Explosion-proof, Flameproof)
Consumption
- Current Consumption: 100 mA Typical
Electrical Connectors
- T-Series Terminal Connection
Electrical Protection
- Overvoltage Protection: up to 36 Vdc
- Polarity Protection: up to -30 Vdc
Enclosure, Body Material
- Sensor Electronics: AISI 303 Stainless Steel 1.4305
- Sensor Electronics: AISI 316L Stainless Steel, 1.4404
Environmental Protection
- Ingress Protection Version N: IP68
- Ingress Protection Version N: IP69K
- Ingress Protection Version N: NEMA 4X Depending on Cable Gland
- IP66
- IP67
Flange Type
- Threaded Flange with Flat-Face (M18 x 1.5-6 G) (3/4”-16 UNF-3A)
- Threaded Flange with Raised-Face (M18 x 1.5-6 G) (3/4”-16 UNF-3A)
Humidity
- 90 % Relative Humidity, Non-Condensing
Hysteresis
- < 4 µm
Length
- Stroke Length: 1 to 60” (25 to 1,500 mm)
Linearity
- < ± 0.01 % of Full Scale (Min. ± 50 µm)
Load
- 0 to 500 ohms
Materials of Construction
- Sensor Rod: AISI 304L Stainless Steel 1.4306
- Sensor Rod: AISI 316L Stainless Steel, 1.4404
Metric Connection
- M16 x 1.5-6H Female - Version E, N
- M18 x 1.5-6 G Female
- M20 x 1.5-6H Female
Mounting Position
- Any Orientation
NPT Connection
- 1/2”-14 Female NPT
Operating Pressure
- psi: 5,076 (kPa: 35,000, bar: 350) Static
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Operating Voltages
- 24 Vdc (-15 / 20 %)
Output
- 0-20 mA
- 20-0 mA
- 20-4 mA
- 4-20 mA
Repeatability
- < ± 0.001 % of Full Scale (Min. ± 2.5 µm)
Resolution
- 0.0015 % (Min. 1 µm)
- 16-bit
Shock
- 100 G (Single Shock) IEC 60068-2-27
Temperature Coefficient
- < 30 ppm / K Typical
UNF/UNC Connection
- 3/4”-16 UNF Female-3A
Vibration
- 15 G (10 to 2,000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)
Voltage
- Dielectric Strength: 700 Vdc (DC Ground to Machine Ground)