Brand: R. STAHL AG

R. STAHL's 8146/5-V27 series molded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. 

The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. 

They cannot be retrofitted.
Features
  • Electric line and system protection for Ex e and Ex d motors
  • Robust enclosure made from glass fibre-reinforced polyester resin
  • Optional: Under voltage release, shunt trip, ammeter, auxiliary contact

1 - 12 of 75 Part Numbers
147203
147203
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 2 x M32 Ø 9 - 21 mm
  • Stopping plug - 1 x M25

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 16.00 - 20.00 A
  • Current-setting range max. - 20.00 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 16.00 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - without
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-301-135-00-3
  • Title Product Variant Technical Data - 8146/5-V27-301-135-00-3 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Type of stopping plug - 8290
  • Weight - 4.200 kg
147204
147204
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 2 x M32 Ø 9 - 21 mm
  • Stopping plug - 1 x M25

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 20.00 - 22.50 A
  • Current-setting range max. - 22.50 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 20.00 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 - 690.00 V
  • Release - without
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-301-145-00-3
  • Title Product Variant Technical Data - 8146/5-V27-301-145-00-3 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Type of stopping plug - 8290
  • Weight - 4.200 kg
249152
249152
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.10 - 0.16 A
  • Current-setting range max. - 0.16 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.10 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 400.00 V
  • Switching capacity - 12,40 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T6 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-108-015-10-2
  • Title Product Variant Technical Data - 8146/5-V27-108-015-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.610 kg
249155
249155
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
249156
249156
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.16 - 0.25 A
  • Current-setting range max. - 0.25 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.16 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 500.00 V
  • Switching capacity - 16,00 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T80 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T80 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T6 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-110-025-10-2
  • Title Product Variant Technical Data - 8146/5-V27-110-025-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.630 kg
249157
249157
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.25 - 0.40 A
  • Current-setting range max. - 0.40 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.25 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 230.00 V
  • Switching capacity - 7,00 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-107-035-10-2
  • Title Product Variant Technical Data - 8146/5-V27-107-035-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.630 kg
249158
249158
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.25 - 0.40 A
  • Current-setting range max. - 0.40 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.25 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 400.00 V
  • Switching capacity - 12,40 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-108-035-10-2
  • Title Product Variant Technical Data - 8146/5-V27-108-035-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.630 kg
249160
249160
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.40 - 0.63 A
  • Current-setting range max. - 0.63 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.40 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 230.00 V
  • Switching capacity - 7,00 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-107-045-10-2
  • Title Product Variant Technical Data - 8146/5-V27-107-045-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.630 kg
249161
249161
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.40 - 0.63 A
  • Current-setting range max. - 0.63 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.40 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 V
  • Rated operational voltage AC - 690.00 - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 400.00 V
  • Switching capacity - 12,40 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-108-045-10-2
  • Title Product Variant Technical Data - 8146/5-V27-108-045-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.630 kg
249162
249162
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.40 - 0.63 A
  • Current-setting range max. - 0.63 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.40 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 500.00 V
  • Switching capacity - 16,00 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-110-045-10-2
  • Title Product Variant Technical Data - 8146/5-V27-110-045-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.630 kg
249163
249163
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.63 - 1.00 A
  • Current-setting range max. - 1.00 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.63 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 230.00 V
  • Switching capacity - 7,00 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-107-055-10-2
  • Title Product Variant Technical Data - 8146/5-V27-107-055-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.630 kg
249164
249164
R. STAHL Moulded Case Circuit Breaker for the Motor Protection
Electric line and system protection for Ex e and Ex d motors

Robust enclosure made from glass fibre-reinforced polyester resin

Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact

Ambient Conditions

  • Ambient temperature - -20°C ... +40°C
  • Ambient temperature max. - +40°C
  • Ambient temperature min. - -20°C

Components

  • Entry type - Standard 8161, moulded material
  • Screw connections - 3 x M25 Ø 7 – 17 mm

Electrical Data

  • Ammeter present - No
  • Auxiliary contacts - without
  • Current-setting range - 0.63 - 1.00 A
  • Current-setting range max. - 1.00 A
  • Frequency range - 50 - 60 Hz
  • Min. current-setting range - 0.63 A
  • No. of poles - 3
  • Rated operational voltage AC - 690.00 - 690.00 V
  • Release - Undervoltage release
  • Release voltage AC - 400.00 V
  • Switching capacity - 12,40 kW
  • Switching capacity AC-3 230 V - 7 kW
  • Switching capacity AC-3 400 V - 12.4 kW
  • Switching capacity AC-3 500 V - 16 kW
  • Switching capacity AC-3 690 V - 22 kW

Explosion Protection

  • Ambient temperature °C - -20 - 40 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - PTB 01 ATEX 1024
  • ATEX gas certificate - PTB 01 ATEX 1024
  • Certificate EAC - TS RU S-DE.AA71.B.00139
  • Certificates - ATEX (PTB), Canada (FM), China (NEPSI), EAC (LPE), IECEx (PTB)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC T95 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T80 °C ... T130 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC T95 °C Db
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T5 Gb
  • Gas explosion protection EAC - 1 Ex e * IIA ... IIC T6 ... T3 Gb X
  • Gas explosion protection IECEx - Ex db eb IIC T5 Gb
  • IECEX dust certificate - IECEx PTB 06.0090
  • IECEX gas certificate - IECEx PTB 06.0090

General

  • Functional Description - R. STAHL's 8146/5-V27 series moulded case circuit breakers for motor protection protect Ex e and Ex d motors and their associated electric lines and systems. The standard variants feature an adjustable, phase-sensitive thermal overcurrent release or electromagnetic tripping mechanism, which has to be specified during the ordering process. They cannot be retrofitted.
  • Highlights - Electric line and system protection for Ex e and Ex d motors Robust enclosure made from glass fibre-reinforced polyester resin Optional: Undervoltage release, shunt trip, ammeter, auxiliary contact
  • Product Description - Moulded case circuit breaker for The motor protection
  • Product Type - 8146/5-V27-108-055-10-2
  • Title Product Variant Technical Data - 8146/5-V27-108-055-10-2 Circ. breaker
  • WebCode - 8146N

Mechanical Data

  • Colour of handle - Black
  • Colour of protective collar - Black
  • Degree of protection (IP) - IP66
  • Enclosure material - Polyester resin, Glass fibre reinforced
  • Labelling rotary actuator - 0 - I
  • Lockable in - 3x in 0
  • Seal - Silicone, foamed
  • Type of screw connection - 8161
  • Weight - 2.630 kg
1 - 12 of 75 Part Numbers