FTPA2000-HP360 FT-NIR Process Analyzer
Brand: ABB GroupThe FTPA2000-HP360 system includes an integrated Ex-certified analyzer cabinet designed for field shelter installation, temperature controlled FT-IR analyzer internal sample system with flow cell(s), full connectivity to DCS via MODBUS or OPC connected via Ethernet to a remote PC data-controller.
The FTPA2000-HP360 series analyzers are designed to provide hydrocarbon quality measurements on a wide range of process liquid and vapour steams including naphtha, gasoline, diesel, kerosene, reformate, C4 / LPG streams and similar applications.
The analyzer internal sample flow cell system provides precise sample temperature control and allows stream quality measurements to be made with excellent repeatability.
Features- Integrated Ex certified analyzer in IP65 enclosure designed for field shelter installation.
- Suitable for light hydrocarbon liquid process streams (up to middle distillate, LGO, Kero) and process vapour streams.
- Full DCS connectivity via ModBUS RTU and OPC
- Calibration and Validation procedures to ASTM D6122 / E1655
- All aspects of system operation, such as sampling system control, referencing, sample analysis, data communication, and data archiving, are controlled by ABB’s FTSW100 Process Software
- Certified for hazardous locations:
- Class 1 Division 2, T3 temperature rating,
- ATEX Category II 2G(EEx pemd [ib] IIC T4 or T3, for hazardous area operation
- NIR optics covering the 3800 to 12,000 cm-1 range,
- Single cell, single fluid switching kit included, upgrade to dual-cell with fully independent process sample inputs available
- Multi-stream and multi-property analyses of refinery hydrocarbon streams with fast response (less than 1 minute per stream)
Specifications
Brand
Certifications & Approvals
- ATEX
Environmental Protection
- IP65
Spectral Range
- 3800 to 12,000 cm-1
Resolution
- 1 to 64 cm-1, in steps of 2x
- Best resolution: 0.7 cm-1 (Unapodized)
Wavenumber Reproducibility
- ± 0.04 cm-1
Wavenumber Repeatability
- ± 0.001 cm-1
Signal-to-RMS-Noise Ratio
- Typically 30,000: 1 for open beam, 1-min scan time, 4 cm-1 resolution
- Naphtha conversion applications – CCR / ISOM
- Naphtha steam-cracker feed for naphtha cracking furnace real-tine optimization
- Gasoline final product quality analysis for blending optimization