Yodify Product Library
Instantly add the 4500 Shear Beam Load Cell and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
4500 Shear Beam Load Cell
Brand: Sensy - Sensors & Synergy S.A.Load cell for silo weighing combining a sturdy design with an easy installation.
Features- Stainless steel
- Protection IP 67
- Cost effective solution
- Sturdy design
- Easy to install
- Mounting kits available with following properties:
- Stabilization without tension rods
- Anti-liftoff device
- Compensation of thermal dilatations and default of parallelism
- Option:
- ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
1 - 4 of 4 Part Numbers
4500-2T-0.1
- Load Cell Capacity: 2 t
- Construction: Stainless Steel
- Breaking Load: 300%
- Maximum Operating Load: 150%
- Accuracy Class: 0.1%
- Cable Length: 6m
- Output Signal (Sensitivity): 2m V/V
- Protection: IP67
- Included Options:
- K-Cable PVC 6X0.14, PVC 6 cond., 1 braid
4500-FORC000026
- Dimensions according to drawing 635381
- Capacity 20,000lb
- Breaking Load 300 %
- Maximum operating load 150 %
- Accuracy class 0.25
- Cable length 3 m
- Protection IP67 M
- Output signal (sensitivity) 10.6 mA
- Included options:
- EX-C6-4/20 2F GD
- ATEX-4-20mA output, Exi, 2 wires gas + dust
- II 1GD Ex ia IIC T6 Ga Ex ia IIIC T80°C Da
- M -CERTIF CHARPY LT
- Charpy V-Notch test 32J@ -20°C
4500-FORC000051
CABLE-4500FORC51
1 - 4 of 4 Part Numbers
Specifications
Accuracy
- 0.1 % of Full Scale
Applications
- Hoppers
- Reactors
- Silos
- Tanks
- Vibrating Mixers
Approvals & Certifications
- ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
- CE
Cable Length
- 20 to 66 feet (6 to 20 metres)
Capacity
- 0.5 to 50 T
Enclosure, Body Material
- Stainless Steel
Environmental Protection
- IP67
Excitation Voltage
- 10 Vdc
Insulation Resistance
- > 5,000 megaohms
Linearity
- Error: < ± 0.1 % of Full Scale
Load
- > 300 % of Full Scale - Breaking Load
- 50 % of Full Scale - Permissible Dynamic Loading
Load Limit
- 150 % of Full Scale
Repeatability
- Error: < ± 0.03 % of Full Scale
Resistance
- Input & Output: 352 ± 2 ohms
Sensitivity
- < ± 0.3 %
Service Temperature
- -30° to 70° C (-22° to 158° F)
Static Lateral Force
- 100 % of Full Scale
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Temperature Coefficient
- < ± 0.035 % of Full Scale/10° C (18° F)
- < ± 0.05 % of Full Scale/10° C (18° F)
Zero Balance
- ± 0.02 mV/V