Brand: Yokogawa Electric CorporationDecades of Yokogawa's innovative measuring technology has resulted in a flexible data logger that offers both reliability and ease of use.
Features- Scalability
- Up to 420 channels per system
- Plug and lock modules
- Ease of Use
- Web-based configuration
- Live web-based data viewing
- Mobile Connectivity
- Bluetooth
- Mobile application
- Reliability
- Secure data storage
- High accuracy measurement
- Automatic backfill function (GA10 data logging software)
- Noise Tolerance
- Electromagnetic relay module
Specifications
Accuracy
- ± 0.5° C (± 0.9° F) [23° C (73.4° F) ± 2° C (± 3.6° F)] - Compensation Accuracy for Typical K, E, J, T, N, XK GOST
- ± 0.7° C (± 1.26° F) [0° to 50° C (32° to 122° F)] - Compensation Accuracy for Typical K, E, J, T, N, XK GOST
- ± 1.4 K [0° to 50° C (32° to 122° F)] - Compensation Accuracy for Typical KpvsAu7F
- ± 1.4° C (± 2.52° F) [0° to 50° C (32° to 122° F)] - Compensation Accuracy for Typical R, S, W, L, U, W97Re3-W75Re25, Platinel 2, NiNiMo, w/WRe26, N(AWG14)
- ± 1° C (± 1.8° F) [-20° to 60° C (-4° to 140° F)] - Compensation Accuracy for Typical K, E, J, T, N, XK GOST
- ± 2 K [-20° to 60° C (-4° to 140° F)] - Compensation Accuracy for Typical KpvsAu7Fe
- ± 2° C (± 3.6° F) [-20° to 60° C (-4° to 140° F)] - Compensation Accuracy for Typical R, S, W, L, U, W97Re3-W75Re25, Platinel 2, NiNiMo, w/WRe26, N(AWG14)
- 1 K [23° C (73.4° F) ± 2° C (± 3.6° F)] - Compensation Accuracy for Typical KpvsAu7Fe
Approvals & Certifications
- CE
- CSA
- GOST
- KC
- NRTL
- UL 61010-1, UL 61010-2-030 (CSA NRTL/C)
Channels
- 10
Communication
- Bluetooth
- DARWIN
- Ethernet - 10Base-T/100Base-TX Port
- EtherNet/IP
- Modbus RTU
- Modbus TCP/IP
- RS-422, RS-485
- Serial Communication Port
- SSL
- USB 2.0
Display
- 7-Segment LED
Electrical Connectors
- M3 Screw Terminal
Frequency
- 50/60 Hz ± 1 %
Humidity
- 55 ± 10 % Relative Humidity, 23 ± 2° C (73.4 ± 3.6° F) - General Operating Condition
Input
- ± 10 Vdc for Other Conditions - Allowable Input Voltage
- ± 60 Vdc for DC Voltage (2 V Range or Higher) / Standard Signal - Allowable Input Voltage
- 0.32 to 5.2 V to Standard Signal
- 0-20 mA DC
- 20 mA - DC Current
- 20 mV - DCV
- -200 mV to 50 V - DCV
- 24 mA 50/60 Hz, Peak Value Including the Signal Portion - Allowable Input Current
- 4-20 mA DC - Standard Current Signal
- 6 V (1-5 V) - DCV
Insulation Resistance
- 20 megaohms or Greater at 500 Vdc between Input Terminals & Internal Circuitry
Measurement Accuracy
- DCV: ± (0.01 % of Reading + 2 mV) - 6 V (1-5 V)
- DCV: ± (0.01 % of Reading + 5 μV) - 20 mV
- ± [0.02 % of Reading + 0.16° C (0.288° F)] - Pt100 (High Resolution)
- ± [0.02 % of Reading + 0.2° C (0.36° F)] - Pt100
- ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.10 % of Reading + 0.2° C (0.36° F)] - T Thermocouple
- ± 0.2° C (± 0.36° F), However, -200° to 0° C (-328° to 0° F): ± [0.15 % of Reading + 0.2° C (0.36° F)] - K Thermocouple [-200° to 500° C (-328° to 932° F)]
- ± 1.1° C (± 1.98° F) - R Thermocouple
Measuring Time
- 1.67 to 100 milliseconds - Integral Time
Mounting
- Clamp Terminal
- Desktop
- DIN Rail
- Wall Mounted
Operating Temperature
- -20° to 60° C (-4° to 140° F)
Output Noise
- Common Mode: 120 dB or more (Integral Time 16.67 milliseconds or more) - Noise Rejection Ratio
- Common Mode: 80 dB or more (Integral Time 1.67 milliseconds) - Noise Rejection Ratio
- Normal Mode: 40 dB or more (Integral Time 16.67 milliseconds or more) - Noise Rejection Ratio
- Normal Mode: 50/60 Hz No Rejection (Integral Time 1.67 milliseconds) - Noise Rejection Ratio
Resistance
- 1 Kiloohm or Less (ON) - Contact DI
- 10 megaohms or more for Thermocouple / DC Voltage (1 V Range or Lower) - Input Resistance
- 100 kiloohms or more (OFF) - Contact DI
- 2 kiloohms or Lower for Thermocouple/DC Voltage - Input External Resistance
- 250 ohms - Input Resistance
- Approximately 1 Megaohm for DC Voltage (2 V Range or Higher) / Standard Signal - Input Resistance
- Maximum
Resistance Effect
- ± 0.1° C (± 0.18° F) / 10 ohms (Lead Resistance between 3-Wires is Equal) for RTD Input - Effect of Wiring Resistance
- Signal Resistance Effect: ± 0.15 % / 1 Kiloohm or Lower for DC Voltage (2 V Range or Higher) / Standard Signal
- Signal Resistance Effect: ± 10 µV / 1 Kiloohm or Lower for Thermocouple / DC Voltage (1 V Range or Lower)
RTD Type
- Cu10
- Cu100
- Cu25
- Cu50
- Cu53
- JPt100
- Ni100
- Ni120
- Pt100
- Pt200
- Pt25
- Pt46
- Pt50
Sensor, Probe Type
- B Thermocouple
- E Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- RTD
- R Thermocouple
- S Thermocouple
- T Thermocouple
- U Thermocouple
- W Thermocouple
Supply Voltage
- 1,000 Vac, 1 Minute (Excluding B Terminal) between Analog Input Channels - Withstand Voltage
- 1,500 Vac, 1 Minute between Input Terminals & Internal Circuitry - Low Withstand Voltage Relay
- 180-264 Vac
- 3,000 Vac, 1 Minute between Input Terminals & Internal Circuitry - Withstand Voltage
- 30 Vac RMS (50/60 Hz) - Max.
- 400 Vac, 1 Minute between Analog Input Channels - Low Withstand Voltage Relay
- 60 Vdc - Max.
- 90-132 Vac
Temperature Effect
- ± (0.05 % of Reading + 0.05 % of Range) or Less Fluctuation Per 10° C (18° F) Change, when Integral Time is 16.67 milliseconds or Higher - Effects of Ambient Temperature
- ± (0.075 % of Reading + 0.05 % of Range) or Less Fluctuation Per 10° C (18° F) Change - Effects of Ambient Temperature
Temperature Range
- -200° to 850° C (-328° to 1,562° F) - RTD
- -270° to 2,320° C (-454° to 4,208° F) - Thermocouples
Update Time
- 30 minutes - Warmup Time