Yodify Product Library
Instantly add the Fibre Optics Fieldbus Isolating Repeater 9186/.5 and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Fibre Optics Fieldbus Isolating Repeater 9186/.5
Brand: R. STAHL AGThe 9186 series FO fieldbus isolating repeater transmits PROFIBUS DP and Modbus RTU signals over distances of up to 2 km as part of redundant fibre optic network structures.
Standard plug connectors can be connected to the inherently safe optical interfaces (Ex op is). The diagnostic functions detect critical signal conditions early and report them to the control room.
Features- For redundant FO network structures (PROFIBUS DP, Modbus RTU) in Zone 2 hazardous areas
- "Ex op is" interface make for easy installation and maintenance
- Diagnostic function for early error detection and signaling
1 - 2 of 2 Part Numbers
160624
For redundant FO network structures (PROFIBUS DP, Modbus RTU) in Zone 2 hazardous areas
"Ex op is" interface make for easy installation and maintenance
Diagnostic function for early error detection and signalling
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +85 °C
- Storage temperature max. - +85 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 130.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 3.00 W
- Voltage range residual ripple - ≤ 3,6 VSS
Components
- Safe interface area - RS-485
Electrical Data
- Connection electrical interfaces - Sub-D socket X1, 9-pole
- Connection optical interface - ST®, BFOC/2.5 socket
- Electrical interface data rate - 9.6 kbps - 1.5 Mbps
- Electrical interface version - RS 485
- Fault control - Power supply failure: Fault-contact is open Transmission level is good: LED green and yellow "FO signal", fault-contact is closed Transmission level reduced (-1,5 dBm): LED yellow "FO ERR", fault-contact is open Fibre breakage or transmission level is too low (-3 dBm): LED red "FO ERR", fault-contact is open
- Field side of interfaces - Ex opis, Fibre optics
- Interface data rate field side - 9,6 kbit/s - 1,5 Mbit/s
- Network structure - end of line, line, point-to-point, point-to-point redundant
- Protocols - HART, Modbus, PROFIBUS DP, ServiceBus R.STAHL (IS1)
- Protocols optical interface - protocol transparent for RS-485 interface
- Redundancy optical interface - automatic switching in case of line fault
- Transmission distance optical Interface - ≤ 2000 m
- Wavelength optical interface - 850 nm
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 07 ATEX 068 X
- ATEX gas certificate - BVS 07 ATEX 068 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada / USA (UL), EAC (STV), IECEx (BVS), India (PESO)
- Dust explosion protection ATEX - II (1) D [Ex op is Da] IIIC
- Dust explosion protection EAC - [Ex op ia Da] IIIC
- Dust explosion protection IECEx - [Ex op is Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 2
- Ex interface zone - 2, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [op is T6 Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [op is T6 Ga] IIC T4 Gb X
- Gas explosion protection IECEx - Ex nA nC [op is T6 Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 13.0107 X
- IECEX gas certificate - IECEx BVS 13.0107 X
- Installation - Zone 2 and in the safe area
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - ABS, CCS, ClassNK, DNVGL
General
- Description - Isolating repeater for installation in Zone 2 / Div. 2 For fieldbus via fibre optic intrinsically safe cables ex op is into Zone 1 / Div. 1 Optical ring possible Extensive diagnostic function and fault-contact Suitable for Profibus DP up to 1.5 MBit/s Further versions and information see data sheet of Series 9186 optical fieldbus-isolating repeater
- Functional Description - The 9186 series FO fieldbus isolating repeater transmits PROFIBUS DP and Modbus RTU signals over distances of up to 2 km as part of redundant fibre optic network structures. Standard plug connectors can be connected to the inherently safe optical interfaces (Ex op is). The diagnostic functions detect critical signal conditions early and report them to the control room.
- Highlights - For redundant FO network structures (PROFIBUS DP, Modbus RTU) in Zone 1 hazardous areas "Ex op is" interface make for easy installation and maintenance diagnostic function for early error detection and signalling
- Product Description - FO fieldbus ISpac
- Product Type - 9186/15-12-11
- Product Variant - Optical fieldbus isolating repeater, Zone 2 / Div. 2
- Title Product Variant Technical Data - 9186/15-12-11 Fibre optic isolating repe
- WebCode - 9186B
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Grid dimension - 35.20 mm
- Weight - 0.244 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Switching capacity fault message contact - max. 60 V DC;42 V AC;0,46 A
160625
For redundant FO network structures (PROFIBUS DP, Modbus RTU) in Zone 2 hazardous areas
"Ex op is" interface make for easy installation and maintenance
Diagnostic function for early error detection and signalling
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95%
- Storage temperature - -40 °C ... +85 °C
- Storage temperature max. - +85 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - 24 V DC
- Auxiliary power voltage range - 18 - 31,2 V
- Nominal current - 130.00 mA
- Nominal voltage - 24 V DC
- Polarity reversal protection - yes
- Power consumption - 3.00 W
- Voltage range residual ripple - ≤ 3,6 VSS
Components
- Safe interface area - RS-485
Electrical Data
- Connection electrical interfaces - Sub-D socket X1, 9-pole
- Connection optical interface - ST®, BFOC/2.5 socket
- Electrical interface data rate - 9.6 kbps - 1.5 Mbps
- Electrical interface version - RS 485
- Fault control - Power supply failure: Fault-contact is open Transmission level is good: LED green and yellow "FO signal", fault-contact is closed Transmission level reduced (-1,5 dBm): LED yellow "FO ERR", fault-contact is open Fibre breakage or transmission level is too low (-3 dBm): LED red "FO ERR", fault-contact is open
- Field side of interfaces - Ex opis, Fibre optics
- Interface data rate field side - 9,6 kbit/s - 1,5 Mbit/s
- Network structure - end of line, point-to-point redundant, ring
- Protocols - PROFIBUS DP
- Protocols optical interface - protocol transparent for RS-485 interface
- Transmission distance optical Interface - ≤ 2000 m
- Wavelength optical interface - 850 nm
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - BVS 07 ATEX 068 X
- ATEX gas certificate - BVS 07 ATEX 068 X
- Certificate EAC - TS RU S-DE.GB04.B.00353
- Certificates - ATEX (BVS), Brazil (ULB), Canada / USA (UL), EAC (STV), IECEx (BVS), India (PESO)
- Dust explosion protection ATEX - II (1) D [Ex op is Da] IIIC
- Dust explosion protection EAC - [Ex op ia Da] IIIC
- Dust explosion protection IECEx - [Ex op is Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 2
- Ex interface zone - 2, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA nC [op is T6 Ga] IIC T4 Gc
- Gas explosion protection EAC - 2 Ex nA nC [op is T6 Ga] IIC T4 Gb X
- Gas explosion protection IECEx - Ex nA nC [op is T6 Ga] IIC T4 Gc
- IECEX dust certificate - IECEx BVS 13.0107 X
- IECEX gas certificate - IECEx BVS 13.0107 X
- Installation - Zone 2 and in the safe area
- Installation in Division NEC 500 - (Class I, II, III) 2
- Ship approval - ABS, CCS, ClassNK, DNVGL
General
- Description - Isolating repeater for installation in Zone 2 / Div. 2 For fieldbus via fibre optic intrinsically safe cables „ex op is“ into Zone 1 / Div. 1 Point-to-point or line structure Extensive diagnostic function and fault-contact Suitable for Profibus DP up to 1.5 MBit/s Further versions and information see data sheet of Series 9186 optical fieldbus-isolating repeater
- Functional Description - The 9186 series FO fieldbus isolating repeater transmits PROFIBUS DP and Modbus RTU signals over distances of up to 2 km as part of redundant fibre optic network structures. Standard plug connectors can be connected to the inherently safe optical interfaces (Ex op is). The diagnostic functions detect critical signal conditions early and report them to the control room.
- Highlights - For redundant FO network structures (PROFIBUS DP, Modbus RTU) in Zone 1 hazardous areas "Ex op is" interface make for easy installation and maintenance diagnostic function for early error detection and signalling
- Product Description - FO fieldbus ISpac
- Product Type - 9186/25-12-11
- Product Variant - Optical fieldbus isolating repeater, Zone 2 / Div. 2
- Title Product Variant Technical Data - 9186/25-12-11 Fibre optic isolating repe
- WebCode - 9186B
Mechanical Data
- Connection cross-section - 0.2-2.5 mm² flexible 0.2-2.5 mm² rigid 0.25-2.5 mm² flexible core end sleeve
- Grid dimension - 35.20 mm
- Weight - 0.244 kg
Mounting / Installation
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - Yes
- Switching capacity fault message contact - max. 60 V DC;42 V AC;0,46 A
1 - 2 of 2 Part Numbers