Yodify Product Library
Instantly add the Ex UPS Series 8265 and 50,000+ more product series to yourĀ store or catalogĀ Ā 
Book Your Demo and See How
or create your store

Ex UPS Series 8265

Brand: R. STAHL AG

Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. 

The measurements for battery capacity and the battery function tests provide even greater reliability.
Features
  • Ex UPS guard battery monitoring in accordance with IEC/EN60079 et seq.
  • Adjustable buffer time
  • Battery function test
  • Potential-free signal outputs
  • Maximum efficiency
  • Increased for reliable triggering of the load fuse

1 - 12 of 19 Part Numbers
258190
258190
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 10 Ah
  • Buffer time max. - 10 min
  • Conduction current - 1.5 A
  • Input voltage - 24 V DC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 50.00 - 200.00 W
  • Rated operational current - 2.100 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/55-622-113
  • Title Product Variant Technical Data - 8265/55-622-113 UPS 24/24V 200 W 10 Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1247.000 mm
  • Weight - 65.000 kg
  • Width - 348.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258201
258201
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 25 Ah
  • Buffer time max. - 60 min
  • Conduction current - 1.5 A
  • Input voltage - 24 V DC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 50.00 - 200.00 W
  • Rated operational current - 2.100 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/55-623-113
  • Title Product Variant Technical Data - 8265/55-623-113 UPS 24/24V 200 W 25 Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1590.000 mm
  • Weight - 84.000 kg
  • Width - 348.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258202
258202
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 40 Ah
  • Buffer time max. - 120 min
  • Conduction current - 1.5 A
  • Input voltage - 24 V DC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 50.00 - 200.00 W
  • Rated operational current - 2.100 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/55-624-113
  • Title Product Variant Technical Data - 8265/55-624-113 UPS 24/24V 200 W 40 Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1590.000 mm
  • Weight - 96.000 kg
  • Width - 348.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258203
258203
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 60 Ah
  • Buffer time max. - 180 min
  • Conduction current - 1.5 A
  • Input voltage - 24 V DC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 50.00 - 200.00 W
  • Rated operational current - 2.100 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/55-625-113
  • Title Product Variant Technical Data - 8265/55-625-113 UPS 24/24V 200 W 60 Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1590.000 mm
  • Weight - 108.000 kg
  • Width - 348.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258204
258204
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 10 Ah
  • Buffer time max. - 10 min
  • Conduction current - 1.5 A
  • Input voltage - 24 V DC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 250.00 - 300.00 W
  • Rated operational current - 10.500 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO), Korea (KGS)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/56-632-113
  • Title Product Variant Technical Data - 8265/56-632-113 UPS 24/24V 300W 10Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1247.000 mm
  • Weight - 65.000 kg
  • Width - 410.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258205
258205
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 25 Ah
  • Buffer time max. - 30 min
  • Conduction current - 1.5 A
  • Input voltage - 24 V DC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 250.00 - 300.00 W
  • Rated operational current - 10.500 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO), Korea (KGS)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/56-633-113
  • Title Product Variant Technical Data - 8265/56-633-113 UPS 24/24V 300W 25Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1590.000 mm
  • Weight - 84.000 kg
  • Width - 410.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258206
258206
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 40 Ah
  • Buffer time max. - 60 min
  • Conduction current - 1.5 A
  • Input voltage - 24 V DC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 250.00 - 300.00 W
  • Rated operational current - 10.500 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO), Korea (KGS)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/56-634-113
  • Title Product Variant Technical Data - 8265/56-634-113 UPS 24/24V 300W 40Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1590.000 mm
  • Weight - 96.000 kg
  • Width - 410.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258207
258207
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 60 Ah
  • Buffer time max. - 120 min
  • Conduction current - 1.5 A
  • Input voltage - 24 V DC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 250.00 - 300.00 W
  • Rated operational current - 10.500 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO), Korea (KGS)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/56-635-113
  • Title Product Variant Technical Data - 8265/56-635-113 UPS 24/24V 300W 60Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1590.000 mm
  • Weight - 108.000 kg
  • Width - 410.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258208
258208
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 10 Ah
  • Buffer time max. - 10 min
  • Conduction current - 1.5 A
  • Input voltage - 100 - 264 V AC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 50.00 - 200.00 W
  • Rated operational current - 2.100 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/55-622-213
  • Title Product Variant Technical Data - 8265/55-622-213 UPS 264/24V 200 W 10 Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1247.000 mm
  • Weight - 76.000 kg
  • Width - 348.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258209
258209
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 25 Ah
  • Buffer time max. - 60 min
  • Conduction current - 1.5 A
  • Input voltage - 100 - 264 V AC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 50.00 - 200.00 W
  • Rated operational current - 2.100 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/55-623-213
  • Title Product Variant Technical Data - 8265/55-623-213 UPS 264/24V 200 W 25 Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1590.000 mm
  • Weight - 95.000 kg
  • Width - 348.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
258210
258210
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse
258211
258211
R. STAHL Ex UPS Standard
Ex UPS guard battery monitoring in accordance withIEC/EN60079 et seq.

Adjustable buffer time

Battery function test

Potential-free signal outputs

Maximum efficiency

Increased for reliable triggering of the load fuse

Ambient Conditions

  • Ambient temperature charging - 0 °C ... +40 °C
  • Ambient temperature discharging - -20 °C ... +40 °C

Electrical Data

  • Battery capacity - 60 Ah
  • Buffer time max. - 180 min
  • Conduction current - 1.5 A
  • Input voltage - 100 - 264 V AC
  • Output voltage for UPS mode - 21,6 ... 27,6 V DC
  • Power - 50.00 - 200.00 W
  • Rated operational current - 2.100 A
  • UPS time - 1 s … 6 h ∞ (via DIP switch)

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX gas certificate - KEMA 04 ATEX 2237 X
  • Certificate ATEX Gas 2 - PTB 06 ATEX 1077
  • Certificates - ATEX (PTB), IECEx (PTB), India (PESO)
  • Gas explosion protection ATEX - II 2 G Ex db eb IIC T6 Gb
  • Gas explosion protection ATEX 2 - II 2 G Ex eb Gb

General

  • Functional Description - Systems and data are put at risk from even brief power failures or large fluctuations in voltage. R. STAHL Series 8265 UPS systems offer compact and flexible protection since their stable output voltage ensures maximum availability via an adjustable UPS time. The measurements for battery capacity and the battery function tests provide even greater reliability.
  • Highlights - Ex UPS guard battery monitoring in accordance with IEC/EN 60079 et seq. Adjustable buffer time Battery function test Potential-free signal outputs Maximum efficiency Increased for reliable triggering of the load fuse
  • Product Description - Ex UPS standard
  • Product Type - 8265/55-625-213
  • Title Product Variant Technical Data - 8265/55-625-213 UPS 264/24V 200 W 60 Ah
  • WebCode - 8265B

Mechanical Data

  • Degree of protection (IP) - IP23
  • Degree of protection note - (IP23 for the battery enclosure)
  • Enclosure material - Polyester resin, Glass fibre reinforced Aluminium, copper-free
  • Height - 1590.000 mm
  • Weight - 119.000 kg
  • Width - 348.000 mm

Output

  • Output voltage - 24 V DC

Safety Data

  • Min. ambient temperature, charging - 0 °C
1 - 12 of 19 Part Numbers

Documentation

Instantly populate your store or catalogĀ 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more