IPAQ C202 Hazardous Temperature Transmitter

Brand: Inor

IPAQ C202 is a digital, easy-to-use temperature transmitter developed specifically for measurements with Pt100 sensors.

Its robust design and high quality gives excellent performance and accuracy also under harsh conditions.

The IPAQ C202 is also available with ATEX and IECEx certificates making it suitable for a wide range of applications.

With the new runtime counter function you can easily supervise the elapsed operational time between calibrations.

1 - 5 of 5 Part Numbers
70ADA00015
70ADA00015
  • Model - Rail Mounting Kit
70ADA00017
70ADA00017
  • Model - Head Mounting Kit
70C2020010
70C2020010
  • Model - IPAQ C202
70C202X010
70C202X010
  • Model - IPAQ C202X (Ex-Approved Version)
70CFGUS001
70CFGUS001
  • Model - PC Configuration Kit (USB-Connection)
1 - 5 of 5 Part Numbers

Specifications

Brand

Accuracy

  • ± 0.1 K, Max.
  • ± 0.1 % of Span - Basic Accuracy
  • ± 0.1°C (± 0.2°F)
  • ± 0.25 % of Span / 25°C - Temperature Influence
  • ± 0.28 % of Span / 50°F - Temperature Influence

Approvals & Certifications

  • ATEX IECEx Ex ia IIC T6 to T4 Ga
  • ATEX II 1 G Ex ia IIC T6 to T4 Ga
  • CE
  • EMC Directive: 2014/30/EU
  • EN 61326-1
  • EN 61326-2-3
  • IEC 60068-2-31, 60068-2-6, 60068-2-27
  • IEC 60751
  • NAMUR

Burn-Out

  • Downscale (≤ 3.6 mA) - Sensor Break & Sensor Short Circuit Monitoring
  • Upscale (≥ 21.0 mA) - Sensor Break & Sensor Short Circuit Monitoring

Current

  • ≤ 0.5 mA - Sensor

Electrical Connectors

  • 16 AWG (1.5 mm²) - Max.

Enclosure, Body Material

  • ABS
  • Polyamide (PA)
  • Polycarbonate

Environmental Protection

  • IP00
  • IP65

Humidity

  • 0 to 98 % Relative Humidity, Non-Condensing

Input

  • Pt100 RTD

Mounting

  • DIN Rail Mounting

Operating Temperature

  • -40°C to 85°C (-40°F to 185°F)

Output

  • 4 - 20 mA - Temperature Linear Output

Output Function

  • NAMUR Output

Output Load

  • 727 ohms at 24 Vdc - Ex Version
  • 818 ohms at 24 Vdc - Standard Version

Power Requirement

  • 6-32 VDC - Standard Version
  • 8-30 VDC - Ex Version

Sensor, Probe Connection

  • 3-Wire

Shock

  • According to IEC 60068-2-27, Test Ea

Span - Minimum

  • 20°C (68°F)

Span & Zero Adjustments

  • ± 10 % of Span for Span < 100°C/180°F - Sensor Error Compensation

Stability

  • ± 0.1 % of Span Per Year - Long-term

Storage Temperature

  • -40°C to 85°C (-40°F to 185°F)

Temperature Range

  • -200°C to 850°C (-328°F to 1,562°F)

Vibration

  • 10 G, 10 to 2000 Hz
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more