Brand: AmphenolThe Amphenol Network Solutions 125GMT10/nrg125GMT10 and 125GMT15/nrg125GMT15 fuse panels are 125A dual-feed and provide 10/10 and 15/15 GMT fuse positions.
Our 125GMT/nrg125GMT panels feature ±12/±24/±48V operating voltages to serve both legacy and “next-gen” network applications.
Engineered into a standard 1RU footprint that support up to 20A GMT fuses in each position, providing ample capacity for distribution to a broad range of components.
The panel is available in standard terminal block outputs or connectorized outputs.
Features- Universal voltage (±12VDC, ±24VDC, and ±48VDC) enables standardization on a single part number for multiple voltages
- Up to 20A fuses for distribution to a variety of network elements
- UL and NEBS compliant to ensure industry-standard safety and functional requirements
- Form C relay contacts provide reliable alarm connections
- Integrated designation cardholder for simple circuit identification
- Fail alarm LEDs indicate fuse and power failures
- Clear, flame-retardant polycarbonate cover (94V-0) protects input and output power connections and wiring from damage
- Optional Individual Circuit Monitoring provides high accuracy, 100% passive monitoring
- Collect voltage and current for both feed and output circuit
- Collect temperature using optional nrgTEMP probes
Specifications
Brand
Voltage Range (Nominal Voltage)
- ± 12 Vdc, ± 24 Vdc and ± 48 Vdc
Maximum Input Load Rating
- Standard Versions: 125 A @ 65C per panel
- Connectorized Versions: 125A @ 55° C per panel (De-Rated to 100A @ 65° C)
Short Circuit withstand Rating
- 5000A
Nominal Power Loss at Full Load
- Less than 45 W per side @ 5,000W full load per side (125 A x 48 V), 125 A @ 65° C per panel
Percentage of Full Power Dissipation at Nominal Voltage
- Less than 0.5 %
Maximum Input Interrupt Device
- 125 % of panel rating (for 125A rated feeds)
Horizontal Input Terminal Studs (with Keps Nuts and flat Washers) for Dual-hole Compression lugs
- Two pairs of 1/4-20 studs on 5/8” centers per terminal [Max. lug width of .5” (12.7 mm)]. Torque bolts (using 7/16” or 12 mm socket) to 50 in/Lb (5.5 N•m), Max.
Input Wire Size
- #8 AWG to #1/0 AWG
Earth GND Terminal Bolts (with Spring Washers and flat Washers) for Dual-hole Compression lug
- Three sets of 1/4-20 threaded holes on 5/8” centers. [Max. lug width of .5” (12.7 mm)]. Torque bolts (using 7/16” or 12 mm socket) to 50 in/Lb (5.5 N•m), Max.
Ground Wire Size
- #6 AWG to #1 AWG
Output Fuse
- 20 A GMT Fuse
Output Load
- 14A continuous GMT fuse
Minimum Short Circuit Interrupt Rating
- 5000A
GMT Fuses
- Cooper Bussmann and Littelfuse
Alarm Relay Contacts
- 2A @ 30 Vdc, 0.6A @ 60 Vdc
Maximum Alarm Card Power Rating
- @ 12 V: 18 mA (0.22W) @ 24 V: 20 mA (0.48W), @ 48 V: 30 mA (1.44W)
Alarm Wire Size
- #24 AWG, typical (#26 to #20 AWG)
Terminals
- Wire wrap or mates with TE Connectivity 3-640428-3
Standard Versions
- Height: 1.75” (44 mm)
- Depth: 13.9” (353 mm)
- Width: 17” (432 mm) without brackets 19” and 23” brackets included with panel
Connectorized Versions
- Height: 1.75” (44 mm)
- Dephth: 13.8” (350 mm) without tie bar 16.5” (419 mm) with tie bar
- Width: 17” (432 mm) without brackets 19” and 23” brackets included with panel
- Tie bar not included with panel
- Cable-end connectors not included with panel
Sensor Accuracy
- -19.99 to +19.99 V: ± 0.3 V
- .20 to -60 V: ± 0.1 V
- +20 to +60 V: ± 0.1 V
Voltage Measurement Range
- -60 to +60 Vdc