Cable Glands Ex e & Ex d & Ex nR & Ex ta Series A2FRC
Brand: R. STAHL AGA2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmored cables and cables with wire-braid armoring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely.
The cable entries are designed to prevent cold flow.
Features- Ex d and Ex e cable entry for all unarmored cables and cables with wire-braid armoring in flexible conduits
- Sealing for the outer cable sheath provided by an explosion-protected displacement seal
- Worldwide certification in accordance with IECEx, ATEX and CSA
1 - 10 of 10 Part Numbers
243625
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-20S16-A2FRC
- Title Product Variant Technical Data - CMP-20s/16A2FRC gland NB M20
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 3.20 - 8.70 mm
- Clamping range max. - 8.70 mm
- Clamping range min. - 3.20 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20s/16
- Inner conduit thread - M20
- Inner sheath - 3.20 … 8.70 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 43.60 mm
- PVC-shroud - PVC04
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M20
- Thread standard - metric
- Weight - 0.110 kg
- Width across corners - 26.40 mm
- Width across flats - 24.00 mm
243626
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-20S-A2FRC
- Title Product Variant Technical Data - CMP-20sA2FRC gland NB M20
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 6.10 - 11.70 mm
- Clamping range max. - 11.70 mm
- Clamping range min. - 6.10 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20s
- Inner conduit thread - M20
- Inner sheath - 6.10 … 11.70 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 43.60 mm
- PVC-shroud - PVC04
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M20
- Thread standard - metric
- Weight - 0.110 kg
- Width across corners - 26.40 mm
- Width across flats - 24.00 mm
243627
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-20-A2FRC
- Title Product Variant Technical Data - CMP-20A2FRC gland NB M20
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 6.50 - 14.00 mm
- Clamping range max. - 14.00 mm
- Clamping range min. - 6.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20
- Inner conduit thread - M20
- Inner sheath - 6.50 … 14.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 42.40 mm
- PVC-shroud - PVC05
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M20
- Thread standard - metric
- Weight - 0.110 kg
- Width across corners - 29.70 mm
- Width across flats - 27.00 mm
243628
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-25-A2FRC
- Title Product Variant Technical Data - CMP-25A2FRC gland NB M25
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 11.10 - 20.00 mm
- Clamping range max. - 20.00 mm
- Clamping range min. - 11.10 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 25
- Inner conduit thread - M25
- Inner sheath - 11.10 … 20.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 50.40 mm
- PVC-shroud - PVC09
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M25
- Thread standard - metric
- Weight - 0.200 kg
- Width across corners - 39.60 mm
- Width across flats - 36.00 mm
243629
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-32-A2FRC
- Title Product Variant Technical Data - CMP-32A2FRC gland NB M32
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 17.00 - 26.30 mm
- Clamping range max. - 26.30 mm
- Clamping range min. - 17.00 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 32
- Inner conduit thread - M32
- Inner sheath - 17.00 … 26.30 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 50.70 mm
- PVC-shroud - PVC10
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M32
- Thread standard - metric
- Weight - 0.240 kg
- Width across corners - 45.10 mm
- Width across flats - 41.00 mm
243630
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-40-A2FRC
- Title Product Variant Technical Data - CMP-40A2FRC gland NB M40
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 23.50 - 32.20 mm
- Clamping range max. - 32.20 mm
- Clamping range min. - 23.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 40
- Inner conduit thread - M40
- Inner sheath - 23.50 … 32.20 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 51.40 mm
- PVC-shroud - PVC13
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M40
- Thread standard - metric
- Weight - 0.330 kg
- Width across corners - 55.00 mm
- Width across flats - 50.00 mm
243631
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-50S-A2FRC
- Title Product Variant Technical Data - CMP-50SA2FRC gland NB M50
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 31.00 - 38.20 mm
- Clamping range max. - 38.20 mm
- Clamping range min. - 31.00 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 50s
- Inner conduit thread - M50
- Inner sheath - 31.00 … 38.20 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 55.20 mm
- PVC-shroud - PVC15
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M50
- Thread standard - metric
- Weight - 0.430 kg
- Width across corners - 60.50 mm
- Width across flats - 55.00 mm
243632
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-50-A2FRC
- Title Product Variant Technical Data - CMP-50A2FRC gland NB M50
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 35.60 - 44.00 mm
- Clamping range max. - 44.00 mm
- Clamping range min. - 35.60 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 50
- Inner conduit thread - M50
- Inner sheath - 35.60 … 44.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 62.00 mm
- PVC-shroud - PVC18
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M50
- Thread standard - metric
- Weight - 0.440 kg
- Width across corners - 66.00 mm
- Width across flats - 60.00 mm
243633
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-63S-A2FRC
- Title Product Variant Technical Data - CMP-63SA2FRC gland NB M63
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 41.50 - 49.90 mm
- Clamping range max. - 49.90 mm
- Clamping range min. - 41.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 63s
- Inner conduit thread - M63
- Inner sheath - 41.50 … 49.90 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 58.40 mm
- PVC-shroud - PVC21
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M63
- Thread standard - metric
- Weight - 0.720 kg
- Width across corners - 77.60 mm
- Width across flats - 70.50 mm
243634
Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits
Sealing for the outer cable sheath provided by an explosion-protected displacement seal
Worldwide certification in accordance with IECEx, ATEX and CSA
Ambient Conditions
- Ambient temperature - -60 °C ... +130 °C
- Ambient temperature max. - +130 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 130 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1068 X
- ATEX firedamp certificate - SIRA 13 ATEX 1068 X
- ATEX gas certificate - SIRA 13 ATEX 1068 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4074 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0023 X
- IECEx firedamp certificate - IECEx SIM 14.0006
- IECEX gas certificate - IECEx SIR 13.0023 X
- IECEx restricted breathing certificate - IECEx SIR 13.0023 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - A2FRC series metal Ex d and Ex e cable entries are designed for all types of unarmoured cables and cables with wire-braid armouring that are run through flexible or rigid conduits. Installation is incredibly easy thanks to a fitting that can be rotated freely. The cable entries are designed to prevent cold flow.
- Highlights - Ex d and Ex e cable entry for all unarmoured cables and cables with wire-braid armouring in flexible conduits Sealing for the outer cable sheath provided by an explosion-protected displacement seal Worldwide certification in accordance with IECEx, ATEX and CSA
- Product Description - Cable gland
- Product Type - CMP-63-A2FRC
- Title Product Variant Technical Data - CMP-63A2FRC gland NB M63
- WebCode - A2FRCA
Mechanical Data
- Armouring type - Unarmoured cable types
- Armouring type 2 - Cable with protective braiding
- Clamping range - 47.20 - 55.90 mm
- Clamping range max. - 55.90 mm
- Clamping range min. - 47.20 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 63
- Inner conduit thread - M63
- Inner sheath - 47.20 … 55.90 mm
- Lot size - 1
- Material - Nickel-plated brass
- Protrusion length - 61.50 mm
- PVC-shroud - PVC23
- Sealing material - SOLO LSF
- Silicone-free - No
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M63
- Thread standard - metric
- Weight - 0.640 kg
- Width across corners - 82.50 mm
- Width across flats - 75.00 mm
1 - 10 of 10 Part Numbers