Type 950XP Explosion-Proof I/P Transducer
Brand: ControlAirNow there's a compact I/P transducer that delivers reliable high performance for the toughest applications in the most hazardous environments: the T950XP from ControlAir.
The 950XP converts an electrical current signal to a stable, pneumatic output to actuate valves. Its NEMA 4X (IP65) housing is designed for both Intrinsically Safe and Explosion-proof operation.
Advanced circuitry includes electronic feedback control for superior vibration protection and highly accurate output.
With flow rates up to 12 SCFM (20 m³/hr), the 950XP has the muscle to drive large valves and actuators. Yet because it typically consumes only 0.05 SCFM (0.11 m³/hr), it not only costs less to buy, it costs less to operate as well.
And because it takes impure air in stride, downtime is reduced, too. The 950XP gives you big flexibility.
Its small footprint can fit into tight spots. Its standard mounting bracket lets you mount it directly on a valve, wall, panel, or pipe. Optional, field-selectable process output ranges reduce downtime and inventory.
And since the 950XP is position insensitive, it gives you even more freedom in mounting and connecting to valves and instruments. As a result of this flexibility, installation goes faster.
Easy access Zero and Span adjustments make bench or field calibration quick and easy. For operating versatility, you may choose direct, reverse, and split range modes.
Features- Output Signal: 4-20 mA
- Pressure Range: 3 to 30 psig (0.207 to 2.068 bar, 20.68 to 206.8 kPa)
- Electrical Connections: 1/2" NPT
- Process Connection: 1/4" NPT
- Temperature Range:
- Operating: -40° to 71°C (-40° to 160°F)
- Storage: -40° to 93°C (-40° to 200°F)
- Accuracy: ±0.10% of span
- Materials of Construction:
- Chromate-treated aluminum with epoxy paint
1 - 12 of 37 Part Numbers
950-AC
950AC
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Factory Preset
- Tapped Exhaust - No
- Agency Approvals - No Additional Approvals
950ACA
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Field Selectable Outputs (0.25% Accuracy)
- Tapped Exhaust - No
- Agency Approvals - No Additional Approvals
950ACAE
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Field Selectable Outputs (0.25% Accuracy)
- Agency Approvals - Approved (FM/CSA or ATEX) for natural Gas media.
950ACAK
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Field Selectable Outputs (0.25% Accuracy)
- Tapped Exhaust - No
- Agency Approvals - ATEX Explosion-Proof & Intrinsically safe
950ACAT
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Field Selectable Outputs (0.25% Accuracy)
- Tapped Exhaust - Yes
- Agency Approvals - No Additional Approvals
950ACATE
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Field Selectable Outputs (0.25% Accuracy)
- Tapped Exhaust - Yes
- Agency Approvals - Approved (FM/CSA or ATEX) for natural Gas media.
950ACATK
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Field Selectable Outputs (0.25% Accuracy)
- Tapped Exhaust - Yes
- Agency Approvals - ATEX Explosion-Proof & Intrinsically safe
950ACE
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Factory Preset
- Agency Approvals - Approved (FM/CSA or ATEX) for natural Gas media.
950ACK
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Factory Preset
- Tapped Exhaust - No
- Agency Approvals - ATEX Explosion-Proof & Intrinsically safe
950ACT
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Factory Preset
- Tapped Exhaust - Yes
- Agency Approvals - No Additional Approvals
950ACTE
- Output - psig: 3 to 15 (bar: 0.20 to 1.0, kPa: 20.7 to 103.4)
- Options - Factory Preset
- Tapped Exhaust - Yes
- Agency Approvals - Approved (FM/CSA or ATEX) for natural Gas media.
1 - 12 of 37 Part Numbers
Specifications
Brand
Accuracy
- ± 0.10 % of Span (± 0.25 with Field-Selectable Option)
Adjustment Type
- Factory Set (Pre-Set)
- Field Adjustable
Approvals & Certifications
- ATEX
- CE
- CSA
- FM
Circuit Protection
- EMI/RFI Protected
- Reverse Polarity
Consumption
- 3.0 scfh (0.11 m³/hour) at Mid Range
Deadband, Approximate
- 0.02 % of Span
Elastomers
- Buna-N
Electrical Connectors
- 1/2” NPT
- M20 x 1.5
Enclosure Finish
- Epoxy Powder-Coated
Enclosure, Body Material
- Chromate Treated Aluminum
Environmental Protection
- IP65
- NEMA 4X / IP65
Flow Rate
- 12.0 SFCM (20.0 m³/hour) at psig: 100 (bar: 7.0, kPa: 700) Supply
- 4.5 SFCM (7.6 m³/hour) at psig: 25 (bar: 1.7, kPa: 170) Supply
Hysteresis
- ± 0.10 % of Span (± 0.25 with Field-Selectable Option)
Input
- 4-20 mA
Mounting
- 2” (50.8 mm) Pipe
- Direct Wall
- Panel
NPT Connection
- 1/4” NPT Female
Operating Temperature
- -40° to 71° C (-40° to 160° F)
Operating Voltages
- 9.5 Vdc @ 20 mA
Output Pressure
- bar: 0.20 to 2.00
- kPa: 20.68 to 206.8
- psig: 3 to 30
Position Effect
- No Measurable Effect
Relief
- Relieving
Repeatability
- ± 0.10 % of Span (± 0.25 with Field-Selectable Option)
RFI/EMI Effect
- < 0.5 % of Span Change in Output Pressure
Storage Temperature
- -40° to 93° C (-40° to 200° F)
Supply Pressure
- psig: 100 (bar: 7, kPa: 700)
Supply Pressure Effect
- No Measurable Effect
Temperature Effect
- ± 0.045 % °F (0.07 % °C) of Span
Trim Material
- Brass
- Stainless Steel
- Zinc-Plated Steel
Vent
- Straight
- Tapped Exhaust
Vibration Effect
- < ± 1.0 % of Span Under the Following Conditions: 5 to 15 Hz at 0.8” Constant Displacement, 15 to 500 Hz at 10 G’s